1. Introduzione
This manual provides detailed instructions for the safe installation, operation, and maintenance of the Leviton 15A, 125V Snap-In Receptacle, Model 1306. This product is designed for panel installation and features 14 AWG, 6-inch long wire leads for connection.
Per garantire il corretto funzionamento e la sicurezza, leggere attentamente il presente manuale prima di iniziare l'installazione o l'uso.
2. Informazioni sulla sicurezza
ATTENZIONE: Rischio di scossa elettrica o incendio. L'installazione o l'uso impropri possono causare lesioni gravi o mortali. Seguire sempre queste linee guida di sicurezza:
- Scollegare l'alimentazione: Always turn off power at the circuit breaker or fuse box before installing or servicing this receptacle. Verify power is off using a voltagetester.
- Personale qualificato: Installation should be performed by a qualified electrician or a person with a thorough understanding of electrical wiring and building codes.
- Cablaggio corretto: Ensure all wire connections are secure and comply with local and national electrical codes.
- Solo per uso interno: This receptacle is intended for indoor use in dry locations unless otherwise specified by its enclosure.
- Do Not Exceed Ratings: Do not connect devices that exceed the receptacle's 15A, 125V rating.
- Ispezionare per danni: Before installation, inspect the receptacle for any signs of damage. Do not install if damaged.
3. Prodotto finitoview
The Leviton Model 1306 is a polarized, snap-in receptacle designed for easy panel mounting. It features a durable thermoplastic body and pre-wired 14 AWG leads for convenient electrical connection. This receptacle is suitable for various applications requiring a reliable 15A, 125V power connection.

Immagine 1: anteriore view of the Leviton 15A, 125V Snap-In Receptacle (Model 1306) in black, showing the polarized outlet configuration and pre-attached wire leads.
4. Configurazione e installazione
Follow these steps for proper installation of the snap-in receptacle:
- Preparare il luogo di installazione: Ensure the panel opening measures approximately 0.97 inches by 0.52 inches. The panel material should be suitable for snap-in mounting.
- Scollegare l'alimentazione: Before proceeding, turn off the power to the circuit at the main service panel. Confirm power is off using a voltagetester.
- Insert Receptacle: Align the receptacle with the prepared opening in the panel. Push firmly until the snap-in clips engage and the receptacle is securely seated.
- Connessioni dei cavi: The receptacle comes with 14 AWG, 6-inch long wire leads. Connect these leads to the appropriate circuit wiring. Ensure the polarity is correct:
- Connect the ribbed (neutral) wire from the receptacle to the neutral (white) wire of the circuit.
- Connect the smooth (hot) wire from the receptacle to the hot (black or colored) wire of the circuit.
- If a ground wire is present in your application, ensure it is properly connected to the system ground.
- Cablaggio sicuro: Ensure all wiring is neatly arranged and secured within the enclosure, preventing any strain on the connections or interference with other components.
- Ripristina alimentazione: Una volta completata l'installazione e verificati tutti i collegamenti, ripristinare l'alimentazione all'interruttore automatico.
- Funzionalità di prova: Plug a known working device into the newly installed receptacle to confirm proper operation.
5. Istruzioni per l'uso
The Leviton 1306 Snap-In Receptacle operates as a standard 15A, 125V electrical outlet. To use, simply plug in any compatible electrical device. Ensure the device's power requirements do not exceed the receptacle's maximum rating of 15 Amperes at 125 Volts.
This receptacle is polarized, meaning it has one slot wider than the other. Ensure that the plug of your device matches this configuration for proper and safe connection.
6. Manutenzione
The Leviton 1306 Snap-In Receptacle requires minimal maintenance. Regular inspection and cleaning are recommended to ensure continued safe operation.
- Pulizia: To clean the receptacle, first disconnect power to the circuit. Use a soft, dry cloth to wipe the surface. Do not use abrasive cleaners or solvents, as these can damage the thermoplastic material.
- Ispezione: Periodically inspect the receptacle for any signs of wear, damage, or loose connections. Look for cracks in the housing, discoloration, or signs of overheating. If any damage is observed, disconnect power and replace the receptacle immediately.
- Condizioni ambientali: Ensure the receptacle is not exposed to moisture or extreme temperatures outside its rated operating range (-40°C to 60°C).
7. Risoluzione Dei Problemi
Se la presa non funziona correttamente, prendere in considerazione i seguenti passaggi per la risoluzione dei problemi:
- Nessun potere:
- Check the circuit breaker or fuse for the circuit. Reset the breaker if it has tripped or replace the fuse if blown.
- Verify that the power supply to the circuit is active using a voltagetester.
- Ensure all wire connections to the receptacle are secure. Turn off power before checking connections.
- Collegamento allentato: If a plug feels loose in the receptacle, disconnect power and inspect the receptacle for damage or wear. Replace if necessary.
- Surriscaldamento: If the receptacle feels warm to the touch, immediately disconnect power and unplug any devices. This could indicate an overload or a faulty connection. Consult a qualified electrician.
If issues persist after troubleshooting, contact a qualified electrician for assistance.
8. Specifiche
| Caratteristica | Dettaglio |
|---|---|
| Numero di modello | 1306 |
| Amprabbia | 15A |
| Voltage | 125V |
| Configurazione | 1-15R (Polarized) |
| Apertura del pannello | 0.97 pollici x 0.52 pollice |
| Wire Gauge | Cavo AWG 14 |
| Wire Lead Length | 6 pollici |
| Materiale | Thermoplastic (Face Material) |
| Colore | Nero |
| Valutazione della temperatura | -40°C a 60°C |
| Approvazioni | UL, CSA, NOM 057 |
| Tipo di montaggio | Panel Installation (Snap-In) |
| Dimensioni del prodotto | Approximately 6.3"L x 1.85"W (Item Package Dimension: 6.30L x 1.85W x 0.67H inches) |
| Peso dell'articolo | 0.04 libbre (0.634 once) |
9. Informazioni sulla garanzia
This Leviton product is covered by a manufacturer's warranty. For specific details regarding the warranty period, coverage, and claims process, please refer to the official Leviton website or contact Leviton customer support directly. Keep your purchase receipt as proof of purchase.
10. Supporto
For technical assistance, installation questions, or further product information, please contact Leviton customer support. You can typically find contact information on the official Leviton webposto (www.leviton.com) o sulla confezione del prodotto.
Quando contatti l'assistenza, tieni a portata di mano il numero di modello del tuo prodotto (1306) e tutte le informazioni rilevanti sull'acquisto.