IV-Twin+ Double Power For Single Rooms
“
Product Information
Specifications
- Installation: Simplex or core drilling in a 200 mm pipe
- Separation: Vertical separation of exhaust and supply
airflows - Energy Efficiency: Heat recovery of 94% (DIN EN 13141-8)
- Moisture Protection: Yes
- Cold Protection: Sensors prevent cooling in winter
- Model: Single Room Ventilation IV-TWIN+
Product Usage Instructions
Installation
To install the Single Room Ventilation IV-TWIN+, follow these
steps:
- Prepare for installation by Simplex or core drilling.
- Ensure installation in a 200 mm pipe.
Operation
Operate the ventilation system as follows:
- Ensure clear vertical separation of exhaust and supply
airflows. - Monitor the sensors to prevent cooling in winter and maintain
moisture protection.
Maintenance
Regular maintenance is essential for optimal performance. Follow
these maintenance tips:
- Clean filters regularly to ensure efficient operation.
- Check sensors periodically to ensure proper functioning.
FAQ
Q: Can this ventilation system be used in multiple rooms?
A: The Single Room Ventilation IV-TWIN+ is designed for
single-room use only.
Q: How often should filters be cleaned?
A: Filters should be cleaned according to the manufacturer’s
recommendations, typically every 3-6 months.
“`
QUICK INSTALLATION:
Simple preparation with Simplex or core drilling. Installation in a 200 mm pipe.
CLEAR SEPARATION:
The exhaust and supply airflows are reliably separated vertically.
ENERGY EFFICIENCY:
Record-breaking heat recovery of 94 % (DIN EN 13141-8).
MOISTURE PROTECTION:
Strong exhaust mode with double Xenion® power quickly removes humidity peaks.
COLD PROTECTION:
Sensors prevent cooling in winter.
SINGLE ROOM VENTILATION IV-TWIN+
MAXIMUM PERFORMANCE FOR MAXIMUM COMFORT
The iV-Twin+ is an innovative ventilation unit for single-room ventilation with double Xenion® power and a heat recovery rate of 94%. The incoming and outgoing airflows are separated vertically, ensuring a reliable supply of fresh air. Thanks to quick installation using Simplex or core drilling, installation in a 200 mm pipe is easy. A strong exhaust mode protects against humidity peaks, while sensors prevent cooling in winter.
TECHNICAL DATA
Air volume flow, heat recovery [m³/h] Exhaust air volume flow [m³/h] Heat recovery [%] Power consumption [W] Sound pressure level, 2 m [dB(A)] Standard sound level difference [dB] Energy efficiency class
5 23 10 45
94 0,5 3 14 38 45 56 A+ / A
Version 12/2024 | Subject to technical changes. No liability accepted for printing errors.
All info and downloads at www.inventer.eu
inVENTer GmbH Ortsstraße 4a D-07751 Löberschütz
Tel.: +49 (0) 36427 211-0 info@inventer.de www.inventer.eu
Documents / Resources
![]() |
inVENTer IV-Twin+ Double Power For Single Rooms [pdf] User Guide IV-Twin, IV-Twin Double Power For Single Rooms, IV-Twin, Double Power For Single Rooms, For Single Rooms, Single Rooms, Rooms |