inVENTer IV-Twin+ Double Power For Single Rooms User Guide

IV-Twin+ Double Power For Single Rooms

Product Information

Specifications

  • Installation: Simplex or core drilling in a 200 mm pipe
  • Separation: Vertical separation of exhaust and supply
    airflows
  • Energy Efficiency: Heat recovery of 94% (DIN EN 13141-8)
  • Moisture Protection: Yes
  • Cold Protection: Sensors prevent cooling in winter
  • Model: Single Room Ventilation IV-TWIN+

Product Usage Instructions

Installation

To install the Single Room Ventilation IV-TWIN+, follow these
steps:

  1. Prepare for installation by Simplex or core drilling.
  2. Ensure installation in a 200 mm pipe.

Operation

Operate the ventilation system as follows:

  1. Ensure clear vertical separation of exhaust and supply
    airflows.
  2. Monitor the sensors to prevent cooling in winter and maintain
    moisture protection.

Maintenance

Regular maintenance is essential for optimal performance. Follow
these maintenance tips:

  • Clean filters regularly to ensure efficient operation.
  • Check sensors periodically to ensure proper functioning.

FAQ

Q: Can this ventilation system be used in multiple rooms?

A: The Single Room Ventilation IV-TWIN+ is designed for
single-room use only.

Q: How often should filters be cleaned?

A: Filters should be cleaned according to the manufacturer’s
recommendations, typically every 3-6 months.

“`

QUICK INSTALLATION:
Simple preparation with Simplex or core drilling. Installation in a 200 mm pipe.
CLEAR SEPARATION:
The exhaust and supply airflows are reliably separated vertically.
ENERGY EFFICIENCY:
Record-breaking heat recovery of 94 % (DIN EN 13141-8).
MOISTURE PROTECTION:
Strong exhaust mode with double Xenion® power quickly removes humidity peaks.
COLD PROTECTION:
Sensors prevent cooling in winter.
SINGLE ROOM VENTILATION IV-TWIN+
MAXIMUM PERFORMANCE FOR MAXIMUM COMFORT
The iV-Twin+ is an innovative ventilation unit for single-room ventilation with double Xenion® power and a heat recovery rate of 94%. The incoming and outgoing airflows are separated vertically, ensuring a reliable supply of fresh air. Thanks to quick installation using Simplex or core drilling, installation in a 200 mm pipe is easy. A strong exhaust mode protects against humidity peaks, while sensors prevent cooling in winter.

TECHNICAL DATA
Air volume flow, heat recovery [m³/h] Exhaust air volume flow [m³/h] Heat recovery [%] Power consumption [W] Sound pressure level, 2 m [dB(A)] Standard sound level difference [dB] Energy efficiency class

5 ­ 23 10 ­ 45
94 0,5 ­ 3 14 ­ 38 45 ­ 56 A+ / A

Version 12/2024 | Subject to technical changes. No liability accepted for printing errors.

All info and downloads at www.inventer.eu

inVENTer GmbH Ortsstraße 4a D-07751 Löberschütz

Tel.: +49 (0) 36427 211-0 info@inventer.de www.inventer.eu

Documents / Resources

inVENTer IV-Twin+ Double Power For Single Rooms [pdf] User Guide
IV-Twin, IV-Twin Double Power For Single Rooms, IV-Twin, Double Power For Single Rooms, For Single Rooms, Single Rooms, Rooms

References

Leave a comment

Your email address will not be published. Required fields are marked *