Interface 6A110 Adaptation mechanical assembly Installation Guide

Interface-logo

Interface 6A110 Adaptation Mechanical Assembly

Interface0-6A110-Adaptation-mechanical-assembly-product

Overview
The 6A110 adaptation assembly is configured for a Comau SMART-5 NJ-60 application and includes a ground platform, adapter plate, flange robot interface, and DIN-standard fasteners. Its engineering drawing is 6A110-Adaptation-000(a) under the revision dates listed in the technical data.

Specifications

Category Specification Value
Accuracy Accuracy Class 0.5
Accuracy Nonlinearity – %FS ±0.1
Accuracy Hysteresis – %FS ±0.1
Accuracy Nonrepeatability – %RO ±0.5
Accuracy Creep, in 20 min – % ±0.1
Temperature Effect on Zero – %RO/°C ±0.01
Temperature Effect on Output – %/°C ±0.05
Temperature Compensated Range -10 to +70 °C (+14 to +158 °F)
Temperature Operating Range -10 to +85 °C (+14 to +185 °F)
Electrical Rated Output – mV/V (Nominal) ±0.4
Electrical Excitation Voltage – V MAX 5
Electrical Crosstalk – % ±1
Electrical Zero Balance – mV/V <2
Electrical Input Resistance – Ω 1K ±10
Electrical Output Resistance – Ω 1K ±10
Electrical Input Resistance – Ω 350 ±10
Electrical Output Resistance – Ω 350 ±10
Mechanical Safe Overload – %CAP 150
Mechanical Ultimate Overload – %RO 300

Dimension

No. Description Metric U.S.
1 2 × Ø6 E7 Ø6 E7 mm 2 × Ø0.2375/0.2370 in
2 6 × M10 × 1.5 M10 × 1.5 6 × M10 × 1.5
3 Diameter Ø110 mm Ø4.3 in
4 Diameter Ø100 mm Ø3.9 in
5 Diameter Ø80 mm Ø3.1 in
6 Spigot Diameter, H8 Ø65 H8 mm Ø2.5609/2.5590 in
7 Angle 60° 60°
8 Angle 45° 45°
9 Dimension 60 mm 2.4 in
10 Dimension 10.0 mm 0.4 in
11 Dimension 28.5 mm 1.12 in
12 Overall Dimension 120 ±1 mm 4.7 ±0.04 in
13 Surface Bolting Surface / Measuring Platform Bolting Surface / Measuring Platform
14 Surface Bolting Surface Bolting Surface
15 Spigot Ø65 H8 – Spigot Ø2.5609/2.5590 – Spigot

Interface0-6A110-Adaptation-mechanical-assembly-featured (5 Interface0-6A110-Adaptation-mechanical-assembly-featured (6 Interface0-6A110-Adaptation-mechanical-assembly-featured (7

Features and Benefits

  • 6-Axis – force and torque in all six axes
  • Capacities – Force/Torque: 1kN/100Nm, 4kN/250Nm, 8kN/500Nm, 10kN/750Nm (224.8lbf/885lbf-in, 899.2lbf/2.2Klbf-in, 1.7Klbf/4.4Klbf-in, 2.2Klbf/6.6Klbf-in)
  • Compact size
  • Force and moment values MUST be calculated using supplied 36-term coefficient matrix
  • Low crosstalk
  • Temperature compensated
  • Optional BX8 amplifier and software can be used for force and moment value calculation

Parts List

Position Qty (Crowd) Art. No. Designation Drawing No.
1 1 8678 8679 6A110 6A110_MP11_000(b)
2 1 – Ground Platform SO062_001(a)
3 1 – Adapter Plate SO062_002(a)
4 1 – Flange Robot –
5 6 9084 s-DIN7984-M8x18 –
6 6 9085 s-DIN7984-M8x20 –
7 6 9086 s-DIN7984-M10x16 –
8 1 9087 s-DIN7979-D6-m6x24-St –
9 1 9088 s-DIN7979-D8-m6x24-St –
10 2 9100 s-DIN7979-D6-m6x16-St –
6A110 Adaptation Assembly
The following diagram shows the exploded view and engineering dimensions of the robotic component assembly, specifically configured for the Comau SMART-5 NJ-60 adaptation.Interface0-6A110-Adaptation-mechanical-assembly-featured (1) Interface0-6A110-Adaptation-mechanical-assembly-featured (2) Interface0-6A110-Adaptation-mechanical-assembly-featured (3) Interface0-6A110-Adaptation-mechanical-assembly-featured (4)
Technical Data & Engineering Specifications
Component Naming: 6A110 Adaptation Comau SMART-5 NJ-60
Drawing Number: 6A110-Adaptation-000(a)
Manufacturer: Interface, Inc. Phone: 480-948-5555 www.interfaceforce.com
General Tolerances: ISO 2768-mK
Edges & Dimensions: DIN 6784 Inside Edges: +0.2 (edge symbol) Outer Edges: +0.2 (edge symbol)
Surface Finish: DIN EN ISO 1302 (Rz16 symbol)
Scale: 1:2
Thread Countersinks: DIN 76 Under 90° / Until 120° Until Thread Outside Diameter
Engineering Revision Date: 20.06.17 (Edit) / 28.06.17 (Tstd.)
Protective Notice: Observe the protective notice DIN 34

Installation / Setup

  1. Inspect assembly and mating components for defects or contamination.
  2. Verify mounting fixture matches specified dimensions and mounting points.
  3. Clean all bolting and locating surfaces.
  4. Align Ø65 H8 spigot with corresponding feature on the mating component.
  5. Position assembly for correct measurement orientation.
  6. Install M10 × 1.5 fasteners through six mounting locations; tighten per instructions.
  7. Ensure full seating—no gaps, rocking, or interference.
  8. With sensor, confirm axes/orientation match test system before loading.

How to Use

  • Secure assembly to a rigid mounting structure.
  • Attach test fixture/load structure to the measuring platform.
  • Confirm load path is centered; avoid unintended contact/interference.
  • Connect 6A110 sensor to measurement electronics as specified.
  • Establish zero condition before testing.
  • Apply loads within sensor’s rated capacity.
  • Record and process all six channels using the 36-term coefficient matrix.
  • After testing, verify unloaded condition of the system.

Maintenance and Cleaning

  • Keep mounting/locating surfaces free from debris.
  • Use a soft, lint-free cloth for dust/light contamination.
  • Avoid abrasives on precision surfaces.
  • Inspect threads for wear or contamination.
  • Regularly check fasteners for tightness.
  • Protect from impact, moisture, and unauthorized modification.
  • Do not machine or alter precision features unless engineered/approved.

Safety Tips

  • Only use with compatible 6A110 and rated hardware.
  • Do not exceed rated force/torque.
  • Ensure mounting structure is rigid and supports loads.
  • Install all fasteners before loading; check for secure fit.
  • Keep hands and objects clear during tests.
  • Avoid impact loads unless the system is rated for them.
  • Do not use damaged or improperly seated components.
  • Verify the load path before operating.

Troubleshooting

Problem Possible Cause Solution
Assembly does not seat properly Contaminated/misaligned locating surfaces Clean and realign spigot and mating feature
Holes do not align Incorrect fixture dimensions/orientation Verify dimensions and mounting pattern
Assembly moves during testing Loose fasteners or inadequate structure Properly secure all mounting points
Unstable measurements Movement/vibration or weak mounting Check load path and increase mounting rigidity
Inconsistent measurements Fixture misalignment or off-axis loading Realign fixture and confirm coordinate system
Sensor won’t return to zero Residual load or mounting stress Remove loads, inspect for unintended stress
Difficult threads Damaged/contaminated threads Clean threads, inspect before installing fasteners
Unexpected force/torque readings Wrong calibration/coefficient matrix Use correct calibration data and matrix

Documents / Resources

PDF thumbnail6A110 Adaptation mechanical assembly
Installation Guide · 6A110, 6A110 Adaptation mechanical assembly, Adaptation mechanical assembly, mechanical assembly

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.