inner-Range-logo

inner Range IR-D-P1E IR Detector Passive PIR Technology

inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-product

Specifications

  • Models: IR-D-P1E, IR-D-P2E, IR-D-P2E-UK
  • Technology: PIR, Microwave (10,525 GHz, 10,587 GHz)
  • Mounting Options: Wall mount (with/without bracket), Ceiling mount (with bracket)
  • Height Range: 2.0 to 3.0 meters (6’7″ to 9’8″)
    inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-29

FAQ

Q: What is the recommended mounting height for the detector?

A: The recommended mounting height is between 2.0 to 3.0 meters (6’7″ to 9’8″), with 2.4 meters (8′) being the ideal height for optimal performance.

Before installation

Manufactur er’s statement

Warning

inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-2

Caution

inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-3

Parts identifications

inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-4

Installation

Disassemble

  1. Unlock the cover
  2. Open the cover
  3. Remove the main unit
    inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-5

Wall mount without bracket

Wire through the base

inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-6

Mount the base

inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-7

Wall mount with bracket

  1. Wire and mount on the wall
    inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-8
  2. Join the base on the bracket
    inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-9
    NOTE
    Adjust the detection direction while jointing.
    Confirming with a walk test is required.
  3. Fix the base with the fixing screws (optional)
    inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-10NOTE
    2 fixing screws are required for the Grade 2 and higher grade installation.

Ceiling mount with bracket

How to change the bracket to the ceiling mounting

inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-11

  1. Wire and mount on the ceiling
    inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-12
  2. Join the base on the bracket
    inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-13NOTE
    Adjust the detection direction while jointing.
    Confirming with a walk test is required.
  3. Fix the base with the fixing screws (optional)
    inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-14NOTE
    2 fixing screws are required for the Grade 2 and higher grade installation.

Assemble and connect

  1. Attach the main unit to the base
    inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-15
  2. Connect wires to the terminal
    inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-16

Power cable length
The power cable should be limited to the following length.

IR-D-P1E

WIRE GAUGE 12 V DC 14 V DC
AWG 22

(0.33 mm²)

520 m 1,130 m
(1,710 ft.) (3, 718 ft.)
AWG 20

(0.52 mm²)

820 m  1,790 m

(5,870 ft.)

2,850 m

(9,350 ft.)

(2,690 ft.)
AWG 18

(0.83 mm²)

1,320 m
(4,330 ft.)

IR-D-P2E

WIRE GAUGE 12 V DC 14 V DC
AWG 22

(0.33 mm²)

410 m 890 m

(2,920 ft.)

(1,350 ft.)
AWG 20

(0.52 mm²)

650 m  1,400 m

(4,590 ft.)

2,240 m

(7,350 ft.)

(2,130 ft.)
AWG 18

(0.83 mm²)

1,030 m

(3,380 ft.)

PEU settings

When using a PEU (Plug-in End of line Unit), no resistors need to be fitted.
The PEU packaged with this detector is designed for Inner Range systems.

inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-17

inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-18

Settings

2-1 Wide/Narrow setting

Set the Flip lens to “Wide” or “Narrow”

Go to 2-2 on to skip 2-1 when using the default “Wide” setting.

inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-19

NOTE
Install the lens so that the letters on the cover and on the lens match your intention.

How to remove the lens

inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-20

How to install the lens

inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-21

Set the jumper pin to “Wide” or “Narrow”

inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-22

Caution
The jumper pin must be “Narrow”, when the lens is set to “Narrow”.

NOTE

  • Default setting is “Wide”.
  • When “Narrow” is selected, MW detection will be disabled.

2-2. Jumper pin settings

inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-23

Checking

Walk test

  1. Confirm that the LED pin is “ON” , then close the cover.
  2. Walk in the detection area to check the detecting performance via LED indication.
    inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-24
  3. Return the LED pin to “OFF” after the walk test, if necessary. 4 Lock the cover
    inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-25NOTE
    Conduct a walk test at least once a year.

Other

Specifications

Model IR-D-P1E IR-D-P2E / UK
Installation
Detection method Passive infrared Passive infrared and Microwave
Coverage Wide15 m (50 ft.) 85°/ Narrow24 m (80 ft.)

( No MW detection at “Narrow” setting )

Detection zones Wide: 78 zones/ Narrow: 18 zones
Mounting height 2.0 to 3.0 m (6’7″ to 9’8″)
Alarm period 2.0 ± 0.5 s
Warm-up period Approx. 60 s (LED blinks)
LED indicator Switchable ON/OFF Green: [1] Warm-up [2] Alarm
Electrical
Power input 9.5 to 16 V DC UL *
Current draw 8 mA (normal)

11 mA (max.) at 12 V DC

11 mA (normal)

14 mA (max.) at 12 V DC

Relay output Alarm N.C. 24 V DC 0.1 A max. (Resistive load)
Tamper N.C. 24 V DC 0.1 A max. (Resistive load)

(Open when the cover is removed.)

Remote LED Terminal: open = OFF 0 V = ON
Environmental
Operation temperature -20to +50(-4°F to +122°F) -20to +45(-4°F to +113°F)
Temperature compensation Digital (SMDA)
Environmental humidity 95% max.
RF interference No alarm 10 V/m
Mechanical
Dimension H: 129.2 x W: 61.5 x D: 50.9 mm (H: 5.09″ x W: 2.42″ x D: 2.00″)
Weight Approx. 95 g (3.35 oz)

(with Bracket : Approx. 125 g (4.41 oz))

Approx. 110 g (3.88 oz)

(with Bracket : Approx. 140 g (4.94 oz))

Mounting Wall, Corner (Indoor)

(with Bracket : Wall, Corner, Ceiling)

  • Specifications and designs are subject to change without prior n otice.
  • These units are designed to detect an intruder and activate an alarm control panel.
    Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion.
    UL * Shall be powered via a UL listed burglar alarm class 2 output power limited power supply that has a min standby power of 4 hrs.

Dimensions

inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-26

Detection area

inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-27

NOTE

  • The * 2.4 m dotted line indicates the recommended mounting height.
  • When “Narrow” is selected at the jumper pin, MW detection will be stopped.

Angle adjustment with bracket IR-D-CW-G2

inner-Range-IR-D-P1E-IR-Detector-Passive-PIR-Technology-fig-28

Compliance

RE Directive 2014/53/EU

  • IR-D-P2E and IR-D-P2E-UK comply with RE Directive 2014/53/EU.
  • Microwave emission Frequency and Power
    • IR-D-P2E: 10.525 GHz 15.78 mW e.i.r.p
    • IR-D-P2E-UK: 10.587 GHz 8.93 mW e.i.r.p
  • The following list indicates the areas of intended use of the equipment and any known restrictions.
    For countries not included in this list, please consult the responsible Spectrum Management Agency.
    • 10.525 GHz: Belgium, Denmark, Finland, Germany, Greece, Italy, Luxembourg, The Netherlands, Spain, Sweden, Iceland, Norway, Switzerland
    • 10.587 GHz: Belgium, France, Germany, Ireland, Luxembourg, The Netherlands, United Kingdom
  • IR-D-P2E and IR-D-P2E-UK also comply with EU radiation exposure limits set forth for an uncontrolled
    environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body.

UK Radio Equipment Regulations 2017

  • IR-D-P2E-UK also comply with UK radiation exposure limits set forth for an uncontrolled environment.
    This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body.
  • The radio equipment type IR-D-P2E-UK is in compliance with Radio Equipment Regulations 2017.

FCC/IC

  • This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
    • This device may not cause harmful interference, and
    • This device must accept any interference received, including interference that may cause undesired operation.
  • This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
    • This device may not cause interference.
    • This device must accept any interference, including interference that may cause undesired operation of the device
  • The end user has to also be informed that any changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate this equipment.

EN 50131-1 Grades and Environmental Class; Security Grade 2, Environmental Class II Applied Standards; EN 50131-2-2 (IR-D-P1E), EN 50131-2-4 (IR-D-P2E and IR-D-P2E-UK ) Tested and certified by Kiwa
PD6662:2017

Global Headquarters
Inner Range Australia
1 Millennium Court, Knoxfield, Victoria, 3180, Australia

Inner Range Middle East
Plot No S20141, PO Box 16854
Jebel Ali Free Zone – South, Dubai, UAE

Inner Range United States
2301 Patriot Blvd
Glenview, IL 60026

Inner Range Canada
200 Foster Crescent Mississauga, Ontario, Canada L5R-3Y5

Inner Range United Kingdom
Units 10-11 Theal Lakes Business Park Moulden Way, Reading, Berkshire RG74GB

Inner Range India
National Sales Office 95 Brigade Road, Bangalore, 560 025 India

Copyright (C) 2023 Inner Range Pty Ltd.

Documents / Resources

inner Range IR-D-P1E IR Detector Passive PIR Technology [pdf] Installation Guide
IR-D-P1E, IR-D-P2E, IR-D-P2E-UK, IR-D-P1E IR Detector Passive PIR Technology, IR-D-P1E, IR Detector Passive PIR Technology, Passive PIR Technology, PIR Technology, Technology

References

Leave a comment

Your email address will not be published. Required fields are marked *