C3M5 PSOCTM Control Evaluation Kit

Product Information

Specifications

  • Product Name: PSOCTM Control C3M5 Evaluation Kit
  • Model: KIT_PSC3M5_EVK
  • Contents:
    1. PSOCTM Control C3M5 EVK board
    2. USB Type-A to USB Type-C cable
    3. Jumper wires
    4. Quick start guide (Printed on the kit package)

Product Usage Instructions

Hardware Setup

Connect the Kit with a test PC using the provided USB Type-C to
Type-A cable.

USB-UART COM Port Setup

  1. Open a UART terminal software like Tera Term or Minicom.
  2. Connect to the kit’s USB-UART COM port with the following
    settings: Stop bit – 1-bit, Flow control – None.
  3. Press the reset button (SW1) on the EVK board to reset the
    device.

Demo Application

  1. Run the pre-programmed code example.
  2. Observe the “Hello World” message on the serial terminal and
    ensure that User LEDs (LED1, LED2) blink sequentially.
  3. Press the enter key or use USER BTN1 to pause or resume the
    blinking of LEDs.
  4. Follow the instructions displayed in the boot-up message.

FAQ

Q: How do I reset the device?

A: Press the reset button (SW1) on the EVK board.

Q: What software can I use for UART communication?

A: You can use software like Tera Term or Minicom for UART
communication.

QUICK START GUIDE
PSOCTM Control C3M5 Evaluation Kit

KIT_PSC3M5_EVK

Kit contents 1. PSOCTM Control C3M5 EVK board 2. USB Type-A to USB Type-C

3. Jumper wires 4. Quick start guide (Printed on the kit package)


www.infineon.com/KIT_PSC3M5_EVK

Hardware setup Connect the Kit with test PC using USB Type C-Type A cable.

1

USB cable connected to the Type C USB connector

2 USB-UART COM port setup

Connect the kit with the UART terminal so ware 1. Open the UART terminal so ware such as Tera Term or
Minicom and connect to the kit’s USB-UART COM port using the following settings:
­ Baud rate: 115200, Data: 8-bit, Parity: None,
Stop bit: 1-bit, Flow control: None
2. Press the reset button (SW1) on the EVK board to reset the device.

3 Demo application

Run the pre-programmed code example
1. Observe that the “Hello World” message is displayed on the serial terminal and terminal and ensure that the two User LEDs (LED1, LED2) blink sequentially.
2. Press the enter key to pause or resume the blinking of the user LEDs. Alternatively use USER BTN1 to pause or resume the blinking.
3. Follow the instructions shown in the boot-up message (see the figure).

Next steps ­ The ModusToolboxTM so ware supports this kit and the associated code examples. ­ Visit the kit website and ModusToolboxTM webpage for more information on code examples supported for this kit and the kit documentation.

Document number: 002-40928 Rev. ** Date: 12/2024
Quick Start Guide

Published by Infineon Technologies AG 81726 Munich, Germany

All rights reserved. © 2024 Infineon Technologies AG
Page 2 of 2

Documents / Resources

infineon C3M5 PSOCTM Control Evaluation Kit [pdf] User Guide
KIT_PSC3M5_EVK, C3M5 PSOCTM Control Evaluation Kit, C3M5, PSOCTM Control Evaluation Kit, Evaluation Kit, Kit

References

Leave a comment

Your email address will not be published. Required fields are marked *