CP-6638 Gilbert Wireless Loop Kit

Product Specifications

  • IP Rating: IP65
  • Battery Life: 4 years
  • Range: Up to 50m
  • Channels: 2 outputs
  • Features: Presence & Activation

Product Usage Instructions

Safety Instructions

Before proceeding with the installation and usage of the Gilbert
Wireless Loop Kit, please ensure to read and follow all safety
instructions provided in the manual.

Installation

  1. Step 1: Mark the hole positions on the ground
    using the mounting base or template as a guide. Ensure correct
    alignment and levelness of the wireless loop.
  2. Step 2: Position the wireless loop over the
    drilled holes and insert bolts through the base into the ground.
    Securely tighten the bolts to anchor the detector in place.

Programming

To program the transmitter and receiver for optimal
functionality, follow the manual programming process outlined in
the user manual. You can pair up to 7 detectors per receiver for
efficient operation.

Calibration

Perform the calibration process when the detector is fixed into
position. This process allows the transmitters paired with the
receiver to readjust to their environment for accurate
detection.

Receiver Option Settings

Adjust the receiver settings based on your requirements,
including options like power settings, frequency, and
enabling/disabling functionalities. Refer to the manual for
detailed instructions on changing these settings.

Detection States

The Gilbert Wireless Loop Kit offers detection variants for both
above-ground surface mount and below-ground embedded installations.
Choose the appropriate variant based on your specific installation
needs.

Frequently Asked Questions (FAQ)

How many transmitters can be stored per channel?

The system can store up to 7 transmitters per channel for
efficient operation.

What is the indication for low battery in the transmitter?

When a message is received from a programmed transmitter, there
will be 4 beeps, and both the warning LED and buzzer will be
activated simultaneously.

How do I reset the memory of programmed detectors?

You can clear programmed detectors by following the memory reset
process outlined in the user manual.

“`

Live technical support
+44 (0)1691 655150

Instruction manual Gilbert Wireless Loop Kit

The system is composed of a magnetic detector and a receiver. Its main innovation lies in the wireless communication of the magnetic detector and the receiver which greatly facilitates installation. Designed for efficient integration, the emitter is easily installed on the ground, ensuring reliable and safe operation. The receiver has 2 relay outputs for the functionalities of impulse detection and security (vehicle presence).

1.1 Safety Instructions
· Reaction time < 60ms · Device with SELV/PELV Power Supply
2. Transmitter And Receiver Terminals

Key features

IP65

4 yrs battery
life

Up to
50m range

2 Ch outputs

Presence &
Activation

7 TX

3. Typical Installation ­ Sliding gate

IN2 Access & Control Ltd. Unit 6A Mile Oak, Maesbury Road Industrial Estate, Oswestry, Shropshire, SY10 8GA, UK Web: www.in2access.co.uk | Email: technical@in2access.co.uk | Monday to Friday 08:30 ­ 17:00

Live technical support
+44 (0)1691 655150
3b. Typical Installation ­ Barrier

4. Receiver Output Connections
Com N/O N/C Com N/O N/C

5. Receiver Led Indicator

Presence Output

Pulse/Open Output

6. Start-up

IN2 Access & Control Ltd. Unit 6A Mile Oak, Maesbury Road Industrial Estate, Oswestry, Shropshire, SY10 8GA, UK Web: www.in2access.co.uk | Email: technical@in2access.co.uk | Monday to Friday 08:30 ­ 17:00

Live technical support
+44 (0)1691 655150
7. Programming Process
Manual programming of transmitter (up to a total of 7 detectors per receiver)
Memory reset (clearing programmed detectors)
8. Calibration Process (To Be Carried Out When Detector Fixed Into Position)
* During these 120sec, the transmitters paired with the receiver readjust to the detection they have in their environment, taking these parameters as the initial value.
Memory Full Indicator
Several beeps for 10 seconds when trying to memorize a new transmitter. The system can store 7 transmitters per channel.
Low Battery Indicator
4 beeps each time a message is received from a programmed transmitter. Both, warning LED and buzzer are activated simultaneously. IN2 Access & Control Ltd. Unit 6A Mile Oak, Maesbury Road Industrial Estate, Oswestry, Shropshire, SY10 8GA, UK
Web: www.in2access.co.uk | Email: technical@in2access.co.uk | Monday to Friday 08:30 ­ 17:00

Live technical support
+44 (0)1691 655150

9. Receiver Option Settings

ON
STANDARD
LOW POWER

Enabled
Disabled *
868,150 MHz
869,525 MHz *

10. Detection States
When a vehicle is first detected, both outputs are triggered. Shortly after the impulse output switches off until the sensor is full clear and another vehicle is detected. The presence output remains on as long as the vehicle is detected by the sensor. Once the vehicle has cleared the sensor, the presence output switches off. (NOTE: DIP 5 (ON) on the receiver enables a 5 sec switch off delay) If multiple detectors are used, the impulse output will switch every time the sensor is activated and deactivated but the presence remains switched as long as one sensor is covered.
IN2 Access & Control Ltd. Unit 6A Mile Oak, Maesbury Road Industrial Estate, Oswestry, Shropshire, SY10 8GA, UK Web: www.in2access.co.uk | Email: technical@in2access.co.uk | Monday to Friday 08:30 ­ 17:00

Live technical support
+44 (0)1691 655150
11. Detector Variants Above ground/ surface mount

Below ground/ embedded

battery

IN2 Access & Control Ltd. Unit 6A Mile Oak, Maesbury Road Industrial Estate, Oswestry, Shropshire, SY10 8GA, UK Web: www.in2access.co.uk | Email: technical@in2access.co.uk | Monday to Friday 08:30 ­ 17:00

Live technical support

+44 (0)1691 655150
Gilbert Wireless Vehicle Detection System Quick start guide
This guide is designed to help you set up and begin using your wireless detection system with ease. Whether you’re installing the sensors in a car park, driveway, or commercial area, Gilbert delivers reliable, real-time vehicle detection without the need for extensive wiring. Follow the steps outlined below to get your system up and running quickly, ensuring optimal performance and accuracy from the outset.

Key features
4 yrs battery
life
2 Ch outputs

Above ground wireless loop

Step 1

1

Carefully mark the hole positions on the

ground using the mounting base or template

as a guide.

Ensure correct alignment and that the wireless loop is level, before continuing.

Once marked, use an appropriate drill and bit suitable for the surface material to drill holes at the marked positions.

IP65
2
Presence &
Activation
Up to 50m range

Step 2
Position the wireless loop over the drilled holes, ensuring correct alignment.
Insert the provided bolts through the holes in the base of the wireless loop and into the drilled holes in the ground.
Using a suitable tool, tighten the bolts securely to ensure the detector is firmly anchored in place.

7 TX
3
Supplied with 2 x 3.6V AA Batteries

Step 3
Once the AA batteries have been installed (supplied with unit), securely reattach the lid, ensuring it is properly sealed to protect against dust and moisture.
With the unit fully assembled, proceed to run the calibration procedure as outlined in the instruction manual. This step is essential to ensure accurate vehicle detection and optimal performance.

IN2 Access & Control Ltd. Unit 6A Mile Oak, Maesbury Road Industrial Estate, Oswestry, Shropshire, SY10 8GA, UK Web: www.in2access.co.uk | Email: technical@in2access.co.uk | Monday to Friday 08:30 ­ 17:00

Live technical support
+44 (0)1691 655150
Gilbert Wireless Vehicle Detection System Quick start guide

Key features
4 yrs battery
life
2 Ch outputs

In-ground wireless loop
1

Step 1
Using a core drill, carefully cut a hole in the grounds surface to accommodate the in-ground wireless loop.
Ensure the hole is sized correctly, allowing enough space for the wireless loop to sit flush with the surface.

IP65

Presence

2

&

Activation

Up to
50m range

7 TX

Supplied

3

with 2 x 3.6V

AA Batteries

Step 2
Mark the hole positions using the mounting base as a guide, ensuring correct alignment and that the wireless loop is level.
Drill holes into the ground at the marked points. Insert the provided bolts through the base and into the drilled holes.
Using a suitable tool, tighten the bolts securely to anchor the unit.
Ensure sealing components provided are used to maintain weather protection.
Step 3
Once the AA batteries have been installed (supplied with unit), securely reattach the lid, ensuring it is properly sealed to protect against dust and moisture.

IN2 Access & Control Ltd. Unit 6A Mile Oak, Maesbury Road Industrial Estate, Oswestry, Shropshire, SY10 8GA, UK Web: www.in2access.co.uk | Email: technical@in2access.co.uk | Monday to Friday 08:30 ­ 17:00

Live technical support
+44 (0)1691 655150
Gilbert Wireless Vehicle Detection System Quick start guide

Key features
4 yrs battery
life
2 Ch outputs

In-ground wireless loop
4

Step 4
With the unit fully assembled, proceed to run the calibration procedure as outlined in the instruction manual. This step is essential to ensure accurate vehicle detection and optimal performance.

IP65

Presence

&

Activation

5

Up to
50m range

Step 5
Backfill any gaps around the wireless loop with a suitable material to ensure stability and prevent water ingress for a flush and secure installation.

7 TX
Supplied with 2 x 3.6V AA Batteries

Gilbert Above-Ground

Gilbert In-Ground

SKU
Gilbert Above-Ground (component): CP-6647 Gilbert Above-Ground (Kit): CP-6639 Receiver: CP-RX GILBERT

SKU
Gilbert In-Ground (component): CP-6646 Gilbert In-Ground (Kit): CP-6638 Receiver: CP-RX GILBERT

IN2 Access & Control Ltd. Unit 6A Mile Oak, Maesbury Road Industrial Estate, Oswestry, Shropshire, SY10 8GA, UK Web: www.in2access.co.uk | Email: technical@in2access.co.uk | Monday to Friday 08:30 ­ 17:00

Documents / Resources

IN2 ACCESS CP-6638 Gilbert Wireless Loop Kit [pdf] Instruction Manual
CP-6638 Gilbert Wireless Loop Kit, CP-6638, Gilbert Wireless Loop Kit, Wireless Loop Kit, Loop Kit

References

Leave a comment

Your email address will not be published. Required fields are marked *