IN-SITE-logo

IN-SITE Installer Friendly Series Single Phase Duplex

IN-SITE-Installer-Friendly-Series-Single-Phase-Duplex-product

Specifications

  • Enclosure Base Dimensions: 16 x 14 x 6 inches (40.64 x 35.56 x 15.24 cm)
  • Enclosure Rating: NEMA 4X
  • Alarm Sound Level: 83 to 85 decibels
  • Power Requirements: 120/208/240V or 120V

Product Usage Instructions

  • A. Level Status indicators will illuminate when floats or set points are activated. An alarm will activate if a float operates out of sequence.
  • B. HOA (Hand-Off-Automatic) buttons control pump mode. Hand mode defaults to Automatic when stop level or redundant off level is reached.
  • C. Pump Run indicators will illuminate when pumps are called to run.
  • D. LED display shows system information including level in inches or centimeters (C-LevelTM only), mode, pump elapsed time, events (cycles), alarm counter, float error count, timed dose override counter (timed dose only), pump ON/OFF times, and sequence ON/OFF times (timed dose only).
  • E. The NEXT button toggles the display.
  • F. UP and SET Push Buttons are used to set pump ON/OFF times, pump operation, date and hour, and activation levels (C-LevelTM only).

FAQ

  • Q: What are the different options available for the control panel models?
  • A: The control panel models include Duplex Timed Dose and Duplex Demand Dose, each with specific features and configurations. The options range from alarm packages, enclosure ratings, starting devices, pump full load amps, pump disconnects, level control applications, and more.
  • Q: How can I control the pump operation using the touchpad features?
  • A: You can control the pump operation by using the HOA buttons to switch between hand-off and automatic modes. The LED display provides information on pump status, and elapsed time, and allows you to set pump ON/OFF times and activation levels.

Introduction

The IFS In-Site® duplex control panel utilizes an innovative circuit board design to control two alternating 120/208/240V single-phase pumps in water and sewage applications. IFS panels feature an easy-to-use touchpad on inner door for programming and system monitoring. The alternating action equalizes pump wear. In addition, this system provides override control should either pump fail. Quick retrieval of all system events can be done by downloading panel information onto a USB flash drive. The panel configuration can be easily converted in the field to either a timed dose or a demand dose. Available with the EZconnex® float system.
Monitor system events including pump run times, pump cycles, alarm conditions, power outages, service calls and more! Quick, convenient reports make diagnosing system conditions easy! Plug the flash drive into the USB port located on the inner door of the IFS In-Site® panel to download system events that occurred. No computer is needed at the site! Use the flash drive (included with the panel) with any computer to download system information and reports. The pre-loaded software on the flash drive formulates system data for you, creating reports quickly in an easy-to-read format so system conditions can be easily identified and corrected. In addition to monitoring system events, the IFS In-Site® panel logs any service calls and changes made to system settings, which helps protect service providers.
The panel can utilize the C-Level™ sensor for continuous level monitoring. It senses the level in the tank and sends a signal to the panel. Pump activation levels can be adjusted by using the panel touchpad. C-Level™ CL40 sensor operating range is 3-39.9 inches (7.6-101.3 cm). C-Level™ CL100 operating range is 3-99.5 inches (7.6-252.7 cm).

  • Five-year limited warranty on panel
  • Two-year limited warranty on C-Level™ Sensor

TOUCH PAD FEATURES

  • A. Level Status indicators illuminate when floats or set points are activated; an alarm will activate if a float operates out of sequence
  • B. HOA (Hand-Off-Automatic) buttons with indication control pump mode; Hand mode defaults to Automatic when stop level or redundant off level is reached
  • C. Pump Run indicators will illuminate when pumps are called to run
  • D. LED display for system information including level in inches or centimeters (C-Level™ only), mode, pumps elapsed time (hh:mm), events (cycles), alarm counter, float error count, timed dose override counter (timed dose only), pump ON/OFF times (timed dose only), and sequence ON/OFF times (timed dose only)
  • E. NEXT push button toggles display
  • F. UP and SET Push Buttons used to set pump ON/OFF times (timed dose only), pump operation (alternate 1-2 and 2-1), date and hour, activation levels (C-Level™ only)

COMPONENTS

  1. Enclosure base measures 16 x 14 x 6 inches (40.64 x 35.56 x 15.24 cm); NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use)
  2. Red LED beacon provides 360° visual check of the alarm condition
  3. The exterior Alarm Test/Normal/Silence switch allows the horn and light to be tested and horn to be silenced in an alarm condition; alarm automatically resets once alarm condition is cleared
  4. The alarm horn provides audio warning of alarm conditions (83 to 85 decibel rating)
  5. Circuit breakers (optional) provide pump disconnect and branch circuit protection
  6. Power relays control the pump by switching electrical lines; Definite-purpose contactors are used when pump full load amps are above 15
  7. Float connection terminal block
  8. Incoming Control/Alarm Terminal Block
  9. Control Power indicator/fuse indicator light illuminates if control power is present in the panel; alarm activates if control fuse is blown
  10. Alarm Power indicator/fuse indicator light illuminates if alarm power is present in the panel (Not shown)
  11. Ground lugs
  12. Incoming pump power connections
  13. RF filter
  14. Power supply
  15. Control fuse
  16. Alarm fuse
  17. USB port for flash drive to download time-stamped system events
  18. Manual report switch date and time stamps service calls

IN-SITE-Installer-Friendly-Series-Single-Phase-Duplex-fig-1

INSTALLER FRIENDLY SERIES

INSTALLER FRIENDLY SERIES® IN-SITE® SINGLE PHASE DUPLEX – Demand or timed dose float-controlled system for pump control, system monitoring, event logging and reporting.

IN-SITE-Installer-Friendly-Series-Single-Phase-Duplex-fig-2

CONTROL PANEL IFI
MODEL TYPE 3 Duplex Timed Dose (includes Option 8AC as standard) $2,853.00
4 Duplex Demand Dose (includes Option 8AC as standard) $2,885.00
ALARM PACKAGE 1 Alarm Package (includes test/normal/silence switch, fuse, red light, & horn) Base
ENCLOSURE RATING W Weatherproof, NEMA 4X (engineered thermoplastic) Base
STARTING DEVICE 1 120/208/240V Base
9 120V only Base
PUMP FULL LOAD AMPS 0 0 – 7 FLA Base
1 7 – 15 FLA Base
2 15 – 20 FLA $129.00
 

PUMP DISCONNECTS

0 No Pump Disconnect Base
4 Circuit Breaker(s) 120V (select STARTING DEVICE Option 9 above) $86.00
Circuit Breaker(s) 120/208/240V (select STARTING DEVICE Option 1 above) $172.00
 

 

 

LEVEL CONTROL APPLICATION

H Floats – Pump Down (select Option 17 below)

Timed dose = timer enable and alarm / Demand dose = stop, start, and alarm

Base
E EZconnex® Float Switch System (select Option 34 or 35 below) Timed Dose – $68.00
Demand Dose – $102.00
X No Floats Timed Dose – $68.00
Demand Dose – $102.00
C C-Level™ Sensor (select Option 24 or 29)* Select Option 3E and/ or 4A & 4D for high water alarm and/or redundant off floats Timed Dose – $68.00
Demand Dose – $102.00

IN-SITE-Installer-Friendly-Series-Single-Phase-Duplex-fig-3

NOTE: Pump down applications only. Industry practices suggest that a secondary device, such as a float switch, be used for redundant activation of the high-level alarm and pump shut off when using the C-Level™ sensor.

OPTIONS DESCRIPTION LIST PRICE
1J Duo Alarm Inputs $34.00
3A Alarm Flasher $66.00
3B Manual Alarm Reset $119.00
3E High Water Alarm Float (must also select Option 17)

Only Available with Level Control Application = C

$34.00
4A Redundant Off

(must also select Option 4D if floats are required)

Timed Dose $0.00
Demand Dose $72.00
4D Redundant Off Float (must also select Option 4A and Option 17) $34.00
6A Auxiliary Alarm Contact, Form C $51.00
 

 

8AC

Display Board Includes: ETM Counter, Events (Cycles) Counter, Alarm Counter, Override Counter (Timed Dose Only), and Lead/ Lag Selector (Demand Dose Only) (included as standard)  

$0.00

10E Lockable Latch – NEMA 4X $51.00
10F Lightning Arrestor (select pump circuit breakers, control, and alarm power combined) $285.00
10K Anti-condensation Heater (must select if the operating temperature is colder than 0 degrees F or -18 degrees C) $124.00
11C Additional NEMA 1 Remote Alarm Panel (must also select Option 6A) $114.00
11D Additional NEMA 4X Remote Alarm Panel (must also select Option 6A) $368.00
15A Control/Alarm Circuit Breaker $112.00
16A 10’ Cord in Lieu of 20’ Cord (per Float) – $3.00
16B 15’ Cord in Lieu of 20’ Cord (per Float) – $2.00
16C 30’ Cord in Lieu of 20’ Cord (per Float) $6.00
16D 40’ Cord in Lieu of 20’ Cord (per Float) $18.00
OPTIONS DESCRIPTION LIST PRICE
17C Sensor Float® / Internally Weighted (per Float) – Mercury $13.00
17D Sensor Float® / Externally Weighted (per Float) – Mercury $15.00
17G SJE MilliAmpMaster™ / Pipe Clamp (per Float) – Mechanical $0.00
17H SJE MilliAmpMaster™ / Externally Weighted (per Float) – Mechanical $8.00
17J Sensor Float® / Pipe Clamp (per Float) – Mercury $6.00
18A Timer Override Float (Timed Dose Float Panel Only) $34.00
19F Fourth Float to Separate Alarm Function from Lag (Demand Dose Float Panel Only) $34.00
24E C-Level™ CL40 Sensor with 25′ Vented Cable $380.00
24F C-Level™ CL40 Sensor with 50′ Vented Cable $425.00
24P C-Level™ CL40 Sensor with 100′ Vented Cable $515.00
24X No C-Level™ CL40 Sensor $0.00
29A C-Level™ CL100 Sensor with 25′ Vented Cable $380.00
29B C-Level™ CL100 Sensor with 50′ Vented Cable $425.00
29C C-Level™ CL100 Sensor with 100′ Vented Cable $515.00
29X No C-Level™ CL100 Sensor $0.00
34D ■ EZconnex® 4-Port, 25’, with 10’ Floats (3) / Pipe Clamp, Sealing Plug $400.00
34E ■ EZconnex® 4-Port, 50’, with 10’ Floats (3) / Pipe Clamp, Sealing Plug $454.00
34G ■ EZconnex® 4-Port, 25’, with 20’ Floats (3) / Pipe Clamp, Sealing Plug $423.00
34H ■ EZconnex® 4-Port, 50’, with 20’ Floats (3) / Pipe Clamp, Sealing Plug $476.00
35D ■ EZconnex® 4-Port, 25’, with 10’ Floats (4) / Pipe Clamp $442.00
35E ■ EZconnex® 4-Port, 50’, with 10’ Floats (4) / Pipe Clamp $496.00
35G ■ EZconnex® 4-Port, 25’, with 20’ Floats (4) / Pipe Clamp $473.00
35H ■ EZconnex® 4-Port, 50’, with 20’ Floats (4) / Pipe Clamp $526.00
  • C-Level™ Sensor lengths up to 300 ft. are available. Call for details.
  • EZconnex® mechanically-activated, narrow-angle float switches with quick-release connections

California Prop 65 requires the following:

WARNING Cancer and Reproductive Harm – www.P65Warnings.ca.gov

CONTACT

Documents / Resources

IN-SITE Installer Friendly Series Single Phase Duplex [pdf] Instruction Manual
15, 16, 17, Installer Friendly Series Single Phase Duplex, Installer Friendly Series Duplex, Single Phase Duplex, Duplex

References

Leave a comment