FireAngel SW1-R Mains Powered Optical Smoke Alarm User Manual

Model: SW1-R

1. Ngwaahịa gafereview

The FireAngel SW1-R is a mains-powered optical smoke alarm designed to provide early warning of fire. It features a 9V backup battery to ensure continuous protection during power outages. The alarm emits a loud 85dB sound at 3 meters and includes LED visual indicators for clear alerts.

This optical smoke alarm is particularly effective at detecting slow-burning fires that produce thick white smoke, making it suitable for general living areas.

Akụkụ ndị bụ isi:

FireAngel SW1-R Smoke Alarm front view

Foto 1: N'ihu view of the FireAngel SW1-R Mains Powered Optical Smoke Alarm.

FireAngel SW1-R Smoke Alarm with packaging and key features

Figure 2: FireAngel SW1-R Smoke Alarm highlighting its 9V backup battery, audible/visual alerts, and large test button.

2. Ozi nchekwa dị mkpa

Please read all instructions carefully before installation and operation. Keep this manual for future reference.

FireAngel SW1-R Smoke Alarm placement guidelines

Figure 3: Illustration of recommended placement guidelines for the smoke alarm, showing distance from walls and light fittings, and unsuitable locations.

3. Ihe ngwugwu

Hụ na ihe niile dị ma ghara imebi emebi mgbe ị meghere ngwugwu ahụ:

4. Ntuziaka nwụnye

Ihe dị mkpa: Installation should only be performed by a competent person or qualified electrician. Ensure the mains power supply is switched off at the consumer unit before commencing installation.

4.1. Nzọụkwụ mbụ etinyere:

  1. Họrọ ebe: Choose a suitable location on the ceiling, adhering to the placement guidelines (refer to Section 2).
  2. Kwụpụ ike: Turn off the mains electricity supply to the circuit where the alarm will be installed.
  3. Wụnye Batrị Ndabere: Open the battery compartment on the alarm unit and insert the supplied 9V battery, observing polarity. Close the compartment securely.

4.2. Mounting the Alarm:

  1. Kaa akara ebe a na-egwupụta ihe: Hold the base plate against the ceiling at your chosen location and mark the two drilling points.
  2. Oghere egwu egwu: Drill holes at the marked points and insert the rawl plugs.
  3. Mount Base Plate: Secure the base plate to the ceiling using the provided screws.
  4. Jikọọ Wiring: Connect the mains wiring (Live, Neutral, Earth, and Interlink if applicable) to the terminal block provided. Ensure connections are secure and correct. The alarm unit connects to this terminal block.
  5. Attach Alarm Unit: Align the smoke alarm unit with the base plate and twist clockwise until it clicks securely into place.
FireAngel SW1-R Smoke Alarm easy installation steps

Figure 4: Visual guide for easy installation, showing steps like installing the backup battery, mounting the bracket, attaching the alarm, and connecting to mains power.

4.3. Interlinking Multiple Alarms:

The SW1-R can be hardwired and interconnected with up to 12 compatible FireAngel mains-powered smoke (SW1), heat (HW1), or carbon monoxide (CW1) alarms. To interlink, connect the interlink wire between the designated terminals on each alarm's base plate. When one interlinked alarm detects a hazard, all connected alarms will sound simultaneously.

4.4. Nyochaa nwụnye mgbe emechara:

  1. Weghachi ike: Turn the mains electricity supply back on.
  2. Nwalee mkpu: Press and hold the Test/Silence button for 5 seconds to confirm the alarm is functioning correctly. A loud, high-pitched sound indicates proper operation.

5. Ntuziaka ọrụ

5.1. Ọrụ nkịtị:

Under normal conditions, the alarm will periodically flash its LED indicator to show it is powered and monitoring for smoke. If smoke is detected, the alarm will sound a loud siren and the LED will flash rapidly.

5.2. Test/Silence Button:

5.3. Sleep Easy Function:

If the 9V backup battery is low, the alarm will emit a regular "chirp" sound. To temporarily silence these low battery chirps for up to 8 hours, press the Test/Silence button. This allows for an uninterrupted night's sleep while still maintaining protection. Replace the battery as soon as possible after using this function.

6. Nlekọta

Regular maintenance ensures the continued reliability and effectiveness of your smoke alarm.

FireAngel SW1-R Smoke Alarm maintenance tips

Figure 5: Visual summary of key maintenance recommendations for the smoke alarm, including monthly testing and quarterly vacuuming.

7. Nchọpụta nsogbu

If your smoke alarm is not operating as expected, refer to the following table for common issues and solutions:

NsogbuIhe nwere ike imeNgwọta
Alarm chirps intermittentlyBatrị nkwado ndabere 9V dị ala.Replace the 9V battery immediately. Use the Sleep Easy function if needed for temporary silence.
Alarm sounds without visible smoke (false alarm)Dust or debris in the sensing chamber; high humidity; cooking fumes; steam.Press the Test/Silence button to temporarily silence. Vacuum the alarm thoroughly. Relocate the alarm if it's consistently affected by cooking fumes or steam.
Alarm does not sound during testNo mains power; flat 9V backup battery; faulty unit.Check mains power supply. Replace 9V battery. If problem persists, contact customer support.
Interlinked alarms do not all soundFaulty interlink wiring; incompatible alarms; too many alarms interlinked.Check interlink wiring connections. Ensure all interlinked alarms are compatible FireAngel models. Do not exceed 12 interlinked alarms.

8. Nka na ụzụ nkọwa

Nọmba nlereanyaSW1-R
Ụdị ihe mmetụtaOptical (Photoelectric)
Isi Iyi IkeMains Powered (230V AC) with 9V DC Battery Backup
Olu mkpu85dB na 3 mita
Interlink CapabilityUp to 12 compatible FireAngel mains-powered alarms
Akụkụ ngwaahịa (D x W x H)4.2D x 12.6W x 12.6H centimita
Ibu Ibu220 grams
Okpomọkụ na-arụ ọrụRefer to product packaging for specific range
Oke iru mmiriRefer to product packaging for specific range
ỤkpụrụTS EN 14604: 2005
UPC816317004422
FireAngel SW1-R Smoke Alarm with UKCA and CE marks

Figure 6: The FireAngel SW1-R Smoke Alarm displaying its UKCA and CE certifications, indicating compliance with safety standards.

9. Akwụkwọ ikike na nkwado ndị ahịa

9.1. Ozi akwụkwọ ikike:

The FireAngel SW1-R Mains Smoke Alarm comes with a 5-afọ akwụkwọ ikike site na ụbọchị ịzụrụ. Akwụkwọ ikike a na-ekpuchi ntụpọ dị na ngwa na arụ ọrụ n'okpuru ojiji nkịtị. Biko dowe ihe akaebe nke ịzụrụ ihe maka akwụkwọ ikike.

The warranty does not cover damage caused by misuse, accidental damage, unauthorized modifications, or failure to follow the instructions in this manual.

9.2. Nkwado ndị ahịa:

For technical assistance, warranty claims, or further information regarding your FireAngel SW1-R smoke alarm, please contact FireAngel customer support. Refer to the FireAngel official webngwugwu saịtị ma ọ bụ ngwaahịa maka nkọwa kọntaktị kachasị ọhụrụ.

Websaịtị: www.fireangel.co.uk (Ọpụample njikọ, ezigbo njikọ nwere ike ịdị iche site na mpaghara)

Akwụkwọ ndị emetụtara - SW1-R

Tupuview Akwụkwọ ntuziaka onye ọrụ FireAngel SW1 Optical Smoke Smoke
User manual for the FireAngel SW1 Optical Smoke Alarm, providing installation, operation, maintenance, troubleshooting, warranty, and disposal information.
Tupuview Ntuziaka Onye Ọrụ Maka Mkpu Okpomọkụ nke FireAngel HW1 Mains
Akwụkwọ ntuziaka zuru oke maka FireAngel HW1 Mains Powered Heat Alarm nwere nkwado batrị 9V. Gụnyere ntinye, nhazi, atụmatụ ịgbachi nkịtị, nhọrọ njikọ, mmezi, nsogbu nsogbu, na ozi gbasara akwụkwọ ikike.
Tupuview FireAngel Smoke & Heat Alarm User Manual: FA6611, FA6615, FA6620, FA6720
Comprehensive user manual for FireAngel FA6611, FA6615, FA6620 optical smoke alarms and FA6720 heat alarm. Covers installation, maintenance, troubleshooting, warranty, and disposal.
Tupuview FireAngel ST-625-INT Smoke Alarm User Manual
Comprehensive user manual for the FireAngel ST-625-INT smoke alarm, covering installation, features, maintenance, and warranty. This guide provides essential safety information and operational instructions.
Tupuview FireAngel FA6111, FA6115, FA6120 Smoke Alarms & FA6215 Heat Alarm User Manual
Comprehensive user manual for FireAngel FA6111, FA6115, FA6120 optical smoke alarms and FA6215 heat alarm, covering installation, maintenance, troubleshooting, features like Silence and Sleep Easy, warranty, and disposal.
Tupuview FireAngel SCB10 Ngwakọta anwụrụ ọkụ na Carbon Monoxide Oti mkpu akwụkwọ ntuziaka
Akwụkwọ ntuziaka onye ọrụ maka FireAngel SCB10, anwụrụ ọkụ nchikota na mkpu carbon monoxide, na-enye ntuziaka zuru oke maka nrụnye, ịrụ ọrụ, nrụzi, na nchekwa maka ebe obibi.