1. Okwu mmalite
This manual provides comprehensive instructions for the installation, operation, and maintenance of your TP-Link Mercusys MS116GS 16-Port Gigabit Switch. The MS116GS is designed to expand your wired network with high-speed Gigabit Ethernet ports, offering features like Plug & Play setup, Isolation Mode, and Loop Prevention for enhanced network performance and security.
2. Ngwaahịa gafereview
The Mercusys MS116GS is a 16-port Gigabit Ethernet switch, ideal for expanding network capacity in homes or small offices. It features a durable metal casing and fanless design for silent operation.

Foto 2.1: N'ihu view of the Mercusys MS116GS 16-Port Gigabit Switch, showing 16 RJ45 ports, LED indicators, and mode switches.
Akụkụ ndị bụ isi:
- Ọdụ ụgbọ mmiri Gigabit zuru ezu: 16 RJ45 ports with 10/100/1000 Mbps auto-negotiation supporting Auto-MDI/MDIX.
- Nkwụnye ma kpọọ: Simple to use and saves time and effort.
- Ụdị iche: Allows one-click client traffic separation for higher security and performance.
- Mgbochi anya: Automatically detects and blocks network loops to prevent broadcast storms.
- Igwe anaghị agba nchara Casing: Allows for efficient heat dissipation and long network life.
- Ọrụ nkpuchi nkịtị: Fanless design for quiet use.
Ọdịnaya ngwugwu:
- Mercusys MS116GS 16-Port Gigabit Switch
- Ihe nkwụnye ọkụ
- Akwụkwọ ntuziaka onye ọrụ
3. Nhazi
The MS116GS switch is designed for easy installation. No software configuration is required.
3.1 Nwụnye anụ ahụ
- Nkwanye: Place the switch on a stable, flat surface, such as a desktop, or mount it in a rack. Ensure adequate ventilation around the device.
- Njikọ ike: Connect the provided power adapter to the switch's power port and then plug the adapter into a standard electrical outlet. The Power LED on the front panel should illuminate.
- Njikọ netwọk: Connect your network devices (e.g., computers, printers, IP cameras, routers) to any of the 16 RJ45 ports using Ethernet cables. The corresponding Link/Act LED for each connected port will light up, indicating an active connection.

Foto 3.1: N'azụ view of the Mercusys MS116GS, showing the power input and ventilation.

Foto 3.2: Illustration of the Plug and Play setup, showing the switch connected to a computer.
3.2 LED egosi
The front panel features LED indicators to monitor the switch's status:
- Igwe ọkụ ọkụ:
- Gbanye: Agbanye mgba ọkụ.
- Gbanyụọ: Agbanyụrụ ọkụ.
- Njikọ / Iwu LEDs (maka ọdụ ụgbọ mmiri ọ bụla):
- On: A device is connected to the corresponding port.
- Flashing: Data is being transmitted or received through the corresponding port.
- Gbanyụọ: Ọ nweghị ngwaọrụ ejikọrọ na ọdụ ụgbọ mmiri kwekọrọ.
4. Ntuziaka ọrụ
The MS116GS switch operates automatically once connected. It supports two special modes: Isolation Mode and Loop Prevention Mode, which can be activated via physical switches on the device.

Foto 4.1: Close-up of the mode switches for Isolation and Loop Prevention, located on the right side of the switch.
4.1 Isolation Mode
Isolation Mode allows for one-click client traffic separation. When enabled, ports 1-14 are isolated from each other, preventing them from communicating directly. All isolated ports can still communicate with ports 15-16 (uplink ports). This mode enhances security and performance by preventing broadcast storms and improving LAN security.
- To enable Isolation Mode: Set the "Isolation" switch to the "On" position.
- To disable Isolation Mode: Set the "Isolation" switch to the "Off" position (Default Mode).
4.2 Loop Prevention Mode
Loop Prevention Mode automatically detects and blocks network loops. A network loop occurs when there are multiple paths between two network devices, which can cause broadcast storms and network instability. When a loop is detected, the switch will block the corresponding port to prevent network disruption.
- To enable Loop Prevention Mode: Set the "Loop Prevention" switch to the "On" position.
- To disable Loop Prevention Mode: Set the "Loop Prevention" switch to the "Off" position (Default Mode).
5. Nlekọta
Proper maintenance ensures the longevity and optimal performance of your MS116GS switch.
- Nhicha: Regularly clean the exterior of the switch with a soft, dry cloth. Do not use liquid or aerosol cleaners.
- Igwe ikuku: Ensure that the ventilation holes on the sides of the switch are not obstructed. Proper airflow is crucial for heat dissipation.
- Ịnye ọkụ: Use only the power adapter provided with the switch. Using an incorrect power adapter may damage the device.
- gburugburu: Operate the switch within its specified temperature and humidity ranges. Avoid placing it in direct sunlight or near heat sources.
6. Nchọpụta nsogbu
This section addresses common issues you might encounter with your MS116GS switch.
6.1 Power LED is Off
- Gbaa mbọ hụ na ejikọrọ ihe nkwụnye ọkụ ahụ na ngbanwe yana igwe eletrik na-arụ ọrụ.
- Hụ na ebe ọkụ eletrik ahụ na-arụ ọrụ nke ọma site na itinye ngwaọrụ ọzọ.
6.2 Link/Act LED is Off for a Connected Device
- Lelee ma eriri Ethernet ahụ dị n'ime ma ọdụ ụgbọ mmiri mgba ọkụ ma ngwaọrụ netwọk ahụ nke ọma.
- Gbaa mbọ hụ na agbanyere ngwaọrụ ejikọrọ na ihe nkwụnye netwọkụ ya na-arụ ọrụ nke ọma.
- Try a different Ethernet cable or a different port on the switch.
- Verify that the cable length does not exceed the maximum recommended length (typically 100 meters for Ethernet).
6.3 Ọsọ netwọkụ dị nwayọ
- Ensure all connected devices and cables support Gigabit Ethernet (1000 Mbps) for optimal performance.
- Check for network loops. If Loop Prevention Mode is off, consider enabling it.
- If Isolation Mode is enabled, ensure it is not inadvertently affecting communication between devices that need to interact directly.
- Malitegharịa ihe mgba ọkụ ahụ na ngwaọrụ ejikọrọ.
7. Nkọwapụta
| Njirimara | Nkọwa |
|---|---|
| Nọmba nlereanya | MS116GS |
| Ụdị | MERCUSYS (TP-Link) |
| Ọnụọgụ nke ọdụ ụgbọ mmiri | 16 x 10/100/1000 Mbps RJ45 Ports |
| Ọnụego mbufe data | 1 Gigabit per second (per port) |
| Ụdị interface | RJ45 |
| Atụmatụ | Auto-Negotiation, Auto-MDI/MDIX, Isolation Mode, Loop Prevention, Traffic Prioritization |
| Casing | Igwe anaghị agba nchara Casing |
| Ọrụ | Silent (Fanless) |
| Agba | Nwa |
| Ibu Ibu | 1.13 kilogram |
| Ngwa dakọtara | Camera, Printer, Computer, Laptop, Smartphone, Tablet |
| Onye nrụpụta | TP-njikọ |
| Mba onye si | China |
8. Akwụkwọ ikike na nkwado
Maka ozi akwụkwọ ikike na nkwado teknụzụ, biko rụtụ aka na Mercusys gọọmentị website or contact your local Mercusys support team. Details regarding spare parts availability and software update guarantees are not provided in the product specifications.
You can find more information and support resources at the official Mercusys websaịtị: www.mercusys.com