1. Ntuziaka nchekwa

WARNING: Read all safety warnings and instructions before operating this pump.

  • This pump is designed for transferring light oils such as diesel, biodiesel, and kerosene ONLY.
  • DO NOT use with gasoline, alcohol, or other highly flammable liquids. This can cause fire or explosion.
  • DO NOT use in hazardous locations where flammable vapors may be present.
  • DO NOT dispense fluid that is thicker than diesel fuel, as the motor may overheat.
  • DO NOT use for continuous running. Allow the pump to cool down after extended use.
  • Ngwaahịa a adabaghị maka iji mmiri mmiri maka oriri mmadụ ma ọ bụ mmiri nwere mmiri.
  • Always wear appropriate personal protective equipment, including eye protection, when operating the pump.
  • Gbaa mbọ hụ na ikuku ikuku dị mma mgbe ị na-arụ ọrụ n'ime oghere agbachiri.
  • Debe ụmụaka na ndị ọrụ na-enweghị ikike pụọ na mpaghara ọrụ.
Warning: Not for use with gasoline or alcoholWarning: Not for use with gasoline or alcohol

Images illustrating warnings against using the pump with gasoline or alcohol.

2. Ngwaahịa gafereview

The TOPWAY 110V AC Electric Self-priming Oil Transfer Pump is designed for efficient and safe transfer of light oils. Its robust construction and self-priming capability make it suitable for various applications in vehicles, agriculture, and machinery.

Akụkụ ndị bụ isi:

  • Enwere ike ibugharị: Ọ dị mfe ibugharị na iji ya n'ebe dị iche iche.
  • Ịmepụta onwe: Eliminates the need for manual priming, simplifying operation.
  • Ihe owuwu na-adịgide adịgide: Features a cast iron impeller and copper motor coil for extended lifespan.
  • Ọnụego nfe dị elu: Capable of transferring up to 16 gallons per minute (GPM).
  • Ngwa dịgasị iche iche: Ideal for diesel, biodiesel, and kerosene transfer in vehicles, caravans, boats, agriculture, and machinery.

Ngwaahịa:

TOPWAY Electric Oil Transfer Pump

Main unit of the TOPWAY Electric Oil Transfer Pump with power cord and fittings.

Pump with Copper Motor, Stable Base, Cast Iron Impeller

Highlighted features: Copper Motor, Stable Base, and Cast Iron Impeller for durability.

Pump with Waterproof Switch, UL Plug, Cooling Fan

Key components: Waterproof Switch, 4FT UL Plug, and Cooling Fan for safe and efficient operation.

3. Nkọwapụta

Nhazi Nkọwapụta Ngwaahịa

Visual representation of the pump's key specifications.

NjirimaraNkọwa
Nlereanya0515
Voltage110V-120V
Ike550W
Ọnụego mgbaba16 GPM (galọn kwa nkeji)
Ebeli elu15m (49 ụkwụ)
Ogologo eriri ike1.2m
Akụrụngwa ahụNkedo Ígwè
Impeller iheNkedo Ígwè
Motor CoilỌla kọpa
Ụdị ọrụEletriki
Mmiri dabara adabaDiesel, Biodiesel, Kerosene (Light Oils)
Mmiri mmiri na-adịghị mmaGasoline, Alcohol, Water, Fluids for human consumption, thick fluids
Ibu Ibu17.96 pound
Akụkụ ngwugwu12.5 x 9.5 x 8 sentimita asatọ

4. Nhazi

Before initial use, ensure all components are present and undamaged. Familiarize yourself with the pump's parts and connections.

Nzọụkwụ Mgbakọ:

  1. Attach the appropriate hose barb fittings to the inlet and outlet ports of the pump. Ensure a tight, leak-free connection.
  2. Connect the suction hose to the inlet port and the discharge hose to the outlet port. Secure hoses with clamps ọ bụrụ na ọ dị mkpa.
  3. Position the pump on a stable, level surface. The integrated stable base provides good support.
  4. Ensure the power switch is in the OFF position before plugging the pump into a 110V-120V AC power source.

Video demonstrating the installation and operation of a similar fuel transfer pump, including hose connections.

Video showing the unboxing and initial setup of an oil transfer pump.

5. Ntuziaka ọrụ

This self-priming pump is designed for ease of use. Follow these steps for safe and effective fluid transfer.

Fluid Transfer Steps:

  1. Place the suction hose into the fluid source (e.g., diesel tank, oil drum).
  2. Direct the discharge hose into the receiving container.
  3. Ensure all connections are secure and there are no kinks in the hoses.
  4. Flip the waterproof switch to the ON position to start the pump. The pump will self-prime and begin transferring fluid.
  5. Monitor the fluid transfer process. Do not leave the pump unattended.
  6. Once the desired amount of fluid has been transferred, or the source is empty, flip the switch to the OFF position.
  7. Kwupu eriri ike na ntinye.
  8. Remove the hoses from the fluid source and receiving container.

Video demonstrating the self-priming capability and fast transfer rate of the 110V AC 16GPM oil transfer pump.

Ihe ngosi vidiyoasing the operation of a 110V AC 550W self-priming electric transfer pump.

6. Nlekọta

Regular maintenance ensures the longevity and optimal performance of your TOPWAY oil transfer pump.

Nhicha na Nchekwa:

  • After each use, clean the hoses and the pump with a small amount of the fluid that was transferred to prevent residue buildup.
  • Ensure the pump is completely drained and dry before storing.
  • Chekwaa mgbapụta ahụ n'ebe dị jụụ, kpọrọ nkụ na-adịghị na ìhè anyanwụ kpọmkwem na oke okpomọkụ.

Nyocha:

  • Periodically inspect the power cord for any damage or fraying.
  • Check hoses and connections for leaks or wear. Replace any damaged parts immediately.

7. Nchọpụta nsogbu

NsogbuIhe nwere ike imeNgwọta
Mgbapụta anaghị ebidoNo power supply, faulty switch, motor issueCheck power connection, ensure switch is ON, inspect motor for damage.
Obere ma ọ bụ enweghị erubaHoses kinked, clogged, air in system, fluid too thick, low fluid levelStraighten hoses, clear blockages, ensure proper priming, use suitable fluid, refill source.
Pump na -ada ụdaAir in system, pump running dry, motor issueEnsure proper priming, do not run dry, inspect motor.
Ntupu sitere na njikọLoose connections, damaged hoses/fittingsTighten all connections, replace damaged hoses or fittings.

8. Akwụkwọ ikike & Nkwado

TOPWAY is committed to providing high-quality products and excellent customer service.

Product Assurance:

Each product is carefully checked and packed before shipment. For any questions or problems about the item you received, such as usage problems, product damage during transportation, etc., please kindly feel free to contact us via Amazon Email. We're standing by to assist you.

Ọrụ mgbe-ahịa gasịrị:

We provide 30 days unconditional return and a 1-year warranty, including technical support and free accessories (consumables not included).

Mxmoonant thanks every customer, because our growth is inseparable from you.

Contact: mxmoonant2@hotmail.com

Akwụkwọ ndị emetụtara - 0515

Tupuview TOPWAY TWM339AHG-1 LCD Module User Manual
User manual for the TOPWAY TWM339AHG-1 LCD Module, detailing specifications, electrical characteristics, function specifications, command listings, and handling precautions. Includes I2C interface information and memory maps.
Tupuview TWM339AAY-1 LCD Module User Manual - Shenzhen Topway Technology
User manual for the TOPWAY TWM339AAY-1 LCD Module, detailing specifications, electrical characteristics, function specifications, and handling precautions.
Tupuview TOPWAY TWM12007-1 LCD Module User Manual - Specifications & Handling
Comprehensive user manual for the TOPWAY TWM12007-1 LCD Module. Includes technical specifications, electrical characteristics, command listings, interfacing details, and essential handling precautions.
Tupuview TOPWAY Smart LCD SGTools Handbook: User Guide for Industrial Displays
Comprehensive user handbook for TOPWAY Smart LCD modules and the SGTools software. Learn about features, functions, UI design, and serial communication for industrial and instrumentation applications.
Tupuview TOPWAY LMT070DDCFWD 7.0-inch LCD Module User Manual
Detailed user manual for the TOPWAY LMT070DDCFWD 7.0-inch TFT-LCD module, covering specifications, electrical characteristics, timing, optical performance, and handling precautions.
Tupuview TWM09002 LCD Module User Manual - TOPWAY
Comprehensive user manual for the TOPWAY TWM09002 LCD Module, detailing its basic specifications, electrical characteristics, function specifications, and essential design and handling precautions.