1. Okwu mmalite
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your IBO BETA2 25-40/180 Hot Water Circulation Pump. Please read this manual thoroughly before installation and retain it for future reference.
The IBO BETA2 25-40/180 circulation pump is a high-efficiency, durable, and reliable pump designed to circulate water in central heating systems, solar installations, or hot water systems. This device features 11 speed settings, allowing for parameter adaptation to various operating conditions. An electronic processor controls the pump's operation. It is equipped with a single-phase motor with a power range of 5 to 22 W. Constructed from high-quality materials, the IBO BETA2 pump ensures optimal performance under all conditions and is resistant to high temperatures. It can operate in ambient temperatures from 0 °C to 40 °C, with the device surface reaching approximately 125 °C and pumped water temperatures up to 110 °C. The pump is designed for easy installation and intuitive use, featuring an electronic display that shows current energy consumption and operating status. Additionally, the pump operates quietly (43 dB) and offers significant energy efficiency, consuming between 1/10 and 1/3 of the energy compared to traditional pumps. The device has a 1 ½ inch diameter connection (180 mm distance between connections). It operates with a capacity of up to 50 liters per minute and can lift water up to a height of 4 meters. The Beta 2 25-40/180 pump includes a power cable and screw fittings.
2. Ntuziaka nchekwa
Always observe the following safety precautions to prevent injury and damage to the pump or property:
- Nchekwa Eletriki: Ensure the power supply matches the pump's specifications (230V). Disconnect power before any installation, maintenance, or repair work. All electrical connections must be performed by a qualified electrician and comply with local regulations.
- Okpomọkụ mmiri: The pump handles liquid temperatures from +2 °C to +110 °C. Ensure the system's operating temperature remains within this range.
- Okpomọkụ gburugburu: Operate the pump in ambient temperatures between 0 °C and 40 °C.
- Nrụgide: Do not exceed the maximum system pressure of 1 MPa.
- Nwụnye: Install the pump in a dry, well-ventilated area, protected from frost and direct sunlight. Ensure proper ventilation to prevent overheating.
- Ijikwa: The pump is heavy (2.92 kg). Use appropriate lifting techniques or assistance during installation.
- Ụmụaka na Ndị Ọrụ Na-enweghị Ikike: Keep children and unauthorized persons away from the pump during operation and maintenance.
3. Ihe mejupụtaraview
The IBO BETA2 25-40/180 circulation pump package typically includes the following items:
- IBO BETA2 25-40/180 Circulation Pump Unit
- Igwe ọkụ ọkụ
- Set of Screw Fittings (for pipe connection)
- Akwụkwọ ntuziaka (akwụkwọ a)

Foto 3.1: IBO BETA2 25-40/180 Hot Water Circulation Pump. This image displays the IBO BETA2 25-40/180 hot water circulation pump. The pump is black, cylindrical in shape with two threaded pipe connections. An electronic display panel is visible on the front, showing 'ECO' and numerical readings, along with two green indicator lights and buttons labeled 'PP1', 'PP2', 'CP1', 'CP2'. A black power cable with a standard European plug is shown detached from the pump, indicating it's included for connection.
4. Ntọala na nwụnye
The IBO BETA2 25-40/180 pump is designed for easy installation. However, professional installation by a qualified technician is recommended to ensure proper functioning and compliance with all local codes and regulations.
4.1 Nyochaa nwụnye tupu etinye ya
- Verify that the installation site meets the ambient temperature requirements (0 °C to 40 °C).
- Ensure the power supply is 230V and adequately protected.
- Confirm that the pipe connections are clean and free of debris.
4.2 Ịkwanye mgbapụta
- Choose a suitable location in the heating or hot water system where the pump can be easily accessed for maintenance.
- Ensure the pump is mounted horizontally with the motor shaft in a horizontal position to ensure proper lubrication and cooling.
- Use the provided screw fittings to connect the pump to the system piping. Ensure a tight, leak-free connection. The connection diameter is 1 ½ inches, with a distance of 180 mm between connections.
4.3 Njikọ eletrik
- Ensure the main power supply is switched off before making any electrical connections.
- Connect the provided power cable to the pump's electrical terminal block according to the wiring diagram (refer to the diagram on the pump or in the packaging if available).
- Connect the other end of the power cable to a grounded 230V power outlet.
- Chọpụta na njikọ niile echekwara na mkpuchi nke ọma.
4.4 System Filling and Venting
- After installation, fill the heating or hot water system with water.
- Vent the system thoroughly to remove any trapped air. Air in the system can cause noise, reduce pump efficiency, and lead to damage.
5. Ntuziaka ọrụ
The IBO BETA2 25-40/180 pump features an electronic control system for intuitive operation.
5.1 Mmalite mbụ
- After ensuring the system is filled and vented, switch on the main power supply to the pump.
- The electronic display will illuminate, showing the current operating status and energy consumption.
5.2 Ịgbanwe Ntọala Ọsọ
The pump offers 11 speed settings to adapt to various system requirements. Use the control buttons on the display panel (e.g., PP1, PP2, CP1, CP2, ECO) to cycle through the available modes and speeds. The display will indicate the selected setting and corresponding energy consumption.
- Ọnọdụ ECO: Maka ọrụ na-arụ ọrụ nke ọma na ike.
- PP Modes: Proportional pressure modes, where pump head adjusts proportionally to flow rate.
- CP Modes: Constant pressure modes, maintaining a constant differential pressure.
Consult your heating system's requirements or a qualified technician to determine the optimal setting for your application.
5.3 Ọrụ Nlekota
The electronic display provides real-time feedback on:
- Current energy consumption (in Watts)
- Selected operating mode/speed
- Any error codes (if applicable)
The pump operates quietly, with a sound pressure level of 43 dB.
6. Nlekọta
Regular maintenance ensures the longevity and efficient operation of your IBO BETA2 25-40/180 pump.
6.1 General Checks (Monthly)
- Visually inspect the pump for any signs of leaks, corrosion, or damage.
- Listen for unusual noises during operation, which could indicate air in the system or mechanical issues.
- Check the electronic display for any error messages.
6.2 System Water Quality
Maintain good water quality in your heating system. Poor water quality can lead to scale buildup, corrosion, and reduced pump performance. Consider using appropriate system inhibitors if recommended for your heating system type.
6.3 Nhicha
Keep the exterior of the pump clean and free from dust and debris to ensure proper heat dissipation.
6.4 Ọrụ Ọkachamara (kwa afọ)
It is recommended to have the pump and heating system inspected by a qualified technician annually to ensure optimal performance and identify any potential issues early.
7. Nchọpụta nsogbu
This section addresses common issues you might encounter with your IBO BETA2 25-40/180 pump. For complex problems, contact a qualified technician.
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Mgbapụta anaghị ebido | Enweghị ọkụ Fụọnụ fuuz / tripi emebi Mgbochi moto | Check power connection and supply Check and replace fuse/reset breaker Disconnect power, check for obstructions in the impeller (professional service recommended) |
| Pump na-agba ọsọ mana enweghị mgbasa mmiri | Ikuku na usoro valves mechiri emechi Ihe mgbochi impeller | Vent the system thoroughly Open all necessary valves in the system Disconnect power, check for obstructions (professional service recommended) |
| Pump na -ada ụda | Ikuku na usoro Cavitation (insufficient system pressure) Nkwalite rụrụ arụ | Wepụ sistemu ahụ Check system pressure and increase if necessary Ensure pump is securely mounted |
| Mgbapụta mgbapụta | Njikọ rụrụ arụ Akara mebiri emebi | Tighten pipe connections Contact a qualified technician for seal replacement |
| Electronic display shows error code | Specific internal fault | Refer to the pump's specific error code list (if available in packaging) or contact technical support. |
8. Nka na ụzụ nkọwa
| Oke | Uru |
|---|---|
| Nlereanya | BETA2 25-40/180 |
| Onye nrụpụta | Röhtenbach |
| Ike moto | 5 - 22 W |
| Voltage | 230 V (+6% / -10%) |
| Ọkwa nchekwa | IP42 |
| Klas mkpuchi moto | H |
| Kachasị Elu Elu | 4 mita |
| Ọnụego nfe kacha | 50 lita kwa nkeji |
| Iru mmiri dị nso | 95% |
| Nrụgide Sistemu kacha | 1 MPa |
| Pumped Liquid Temperature | +2 Celsius C ruo +110 Celsius |
| Okpomọkụ gburugburu | 0 Celsius C ruo 40 Celsius |
| Ọkwa Nrụgide ụda | 43 dB(A) |
| Dayameta njikọ | 1 ½ inches (180 mm between connections) |
| Akụkụ ngwaahịa (L x W x H) | 21 x 18 x 11 cm |
| Ibu Ibu | 2.92 n'arọ |
| Ihe onwunwe | Nkedo Ígwè |
| Agba | Nwa |
| Ụdị isi iyi ike | Igwe ọkụ eletrik |
9. Akwụkwọ ikike Ozi
Specific warranty details for the IBO BETA2 25-40/180 pump are not provided in the available product information. Please refer to your purchase documentation or contact your retailer for warranty terms and conditions.
10. Nkwado na kọntaktị
For technical assistance, spare parts, or service inquiries, please contact the retailer from whom you purchased the IBO BETA2 25-40/180 pump. Keep your purchase receipt and product model information readily available when contacting support.
Onye nrụpụta: Röhtenbach