Wilo 4190420

Wilo Star S 33 FC Circulating Pump User Manual

Ụdị: 4190420

1. Okwu mmalite

The Wilo Star S 33 FC 4190420 is a three-speed hydronic radiant floor circulating pump designed for efficient water circulation in various heating applications. Its robust cast iron housing and built-in motor protection ensure long life and reliable performance. This pump is suitable for closed-loop radiant heating, snow melting systems, baseboard, radiator, and fan coil heating applications.

Atụmatụ gụnyere:

2. Ozi nchekwa

Ịdọ aka ná ntị: To reduce the risk of electric shock, consult the instruction manual for proper installation and operation. Always disconnect power before servicing the pump.

kpachara anya: The pump surface can become Ọkụ during operation. Avoid direct contact to prevent burns. Allow the pump to cool before handling or performing maintenance.

3. Ngwaahịa gafereview na akụrụngwa

Wilo Star S 33 FC Circulating Pump, green cast iron body with black electrical box and control dial.

Figure 1: Wilo Star S 33 FC Circulating Pump. This image shows the main body of the pump, its electrical connection box, and the speed selection dial. The green cast iron housing is visible, along with the product label detailing specifications and warnings.

The Wilo Star S 33 FC pump consists of several key components:

4. Nwụnye na Ntọala

Proper installation is crucial for the pump's performance and longevity. Refer to local plumbing and electrical codes.

  1. Ịkwanye: Securely mount the pump using its fixed flanges in the designated location within your hydronic system. Ensure the pump is installed in a horizontal position with the motor shaft horizontal to prevent air pockets.
  2. Njikọ Plumb: Connect the system piping to the pump's flanges. Use the provided gaskets (O-rings) to ensure a watertight seal. Avoid overtightening connections.
  3. Ọkụ eletrik:
    • Ensure the power supply is disconnected before wiring.
    • Connect the pump to a 115-Volt (AC), 60Hz power supply. The pump draws a maximum of 1.5A.
    • Follow the wiring diagram provided inside the electrical connection box.
    • Gbaa mbọ hụ na ntọ ala kwesịrị ekwesị iji gbochie ihe egwu eletrik.
  4. System Filling and Purging: After installation, fill the hydronic system with water and thoroughly purge any air from the system. Air in the system can cause noise and reduce pump efficiency.

5. Ntuziaka ọrụ

The Wilo Star S 33 FC features a three-speed motor, allowing you to adjust the pump's performance to match your system's requirements.

  1. Ike Na: Once installed and the system is filled, restore power to the pump.
  2. Nhọrọ ọsọ ọsọ: Locate the speed selection dial on the front of the pump (refer to Figure 1). The dial has settings for "max", "3", "2", "1", and "eco".
    • Speed 3 (Max): Provides the highest flow rate and pressure. Power consumption is approximately 202W.
    • Ọsọ 2: Medium flow rate and pressure. Power consumption is approximately 143W.
    • Speed 1 (Eco): Lowest flow rate and pressure, designed for energy efficiency. Power consumption is approximately 98W.
    Rotate the dial to select the desired speed setting. The optimal speed depends on your specific heating system's design and heat load requirements. Start with a lower speed and increase if insufficient circulation is observed.
  3. Lelee Valve: The built-in check valve can be removed if not required by your system design. Consult your HVAC professional if unsure.

6. Nlekọta

The Wilo Star S 33 FC pump is designed for minimal maintenance. However, periodic checks can ensure optimal performance and extend its lifespan.

7. Nchọpụta nsogbu

Rụtụ aka na tebụl na-esonụ maka okwu nkịtị na ihe ngwọta ha nwere ike ime.

NsogbuIhe nwere ike imeNgwọta
Mgbapụta anaghị ebidoNo power supply; Motor overload; Impeller jammed.Check power connection and circuit breaker; Allow motor to cool; Disconnect power and check for obstructions in impeller.
Ezughị oke erubaAir in system; Incorrect speed setting; Clogged filter/piping.Purge air from system; Increase speed setting; Check and clean filters or piping.
Ọrụ mkpọtụAir in system; Cavitation; Loose mounting.Purge air from system; Ensure adequate system pressure; Check mounting bolts for tightness.
Mgbapụta mgbapụtaLoose connections; Damaged gaskets/seals.Tighten connections; Replace gaskets or seals.

If the problem persists after attempting these solutions, contact a qualified service technician or Wilo customer support.

8. Nkọwapụta

NjirimaraNkọwa
Nọmba nlereanya4190420
ỤdịWilo
Ihe onwunweNkedo Ígwè
Voltage115 volts (AC)
Ugboro ugboro60 Hz
Ihe osise kacha ugbu a1.5 Amps
Power Consumption (Speed 3)202 Watt
Power Consumption (Speed 2)143 Watt
Power Consumption (Speed 1/Eco)98 Watt
Ibu Ibu9.46 pound (4.3 Kilogram)
Akụkụ ngwugwu7.4 x 7.24 x 5.12 sentimita asatọ
Klas mkpuchiCSA enclosure 2
Klas mkpuchiKlas F
Oke. Okpomọkụ mmiri230°F (110°C)
Oke. Nrụgide arụ ọrụ145 PSI (mmanya 10)
AsambodoUL/CSA listed

9. Akwụkwọ ikike na nkwado

Wilo products are manufactured to high standards and come with a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Wilo websaịtị.

For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Wilo customer service. Contact information can typically be found on the Wilo websaịtị ma ọ bụ na nnata ịzụrụ ihe.

Wilo Official Websaịtị: www.wilo.com