This user manual provides comprehensive instructions for the operation, maintenance, and troubleshooting of the Tektronix MSO44 4-BW-200 Mixed Signal Oscilloscope. This advanced instrument is designed for precise signal analysis, offering high resolution and versatile measurement capabilities for various applications, including embedded systems, power electronics, and automotive electronics.

Tektronix MSO44 4-BW-200 Mixed Signal Oscilloscope

Foto 1: N'ihu view of the Tektronix MSO44 4-BW-200 Mixed Signal Oscilloscope, showcasing its large touchscreen display, multiple input channels, and control knobs. The device features a blue handle for portability.

2. Nhazi na nhazi mbido

2.1 Mwepu na nyocha

Carefully remove the oscilloscope from its packaging. Inspect the unit for any signs of physical damage that may have occurred during transit. Retain the original packaging for future transportation or storage.

2.2 Njikọ ike

  1. Ensure the oscilloscope's power switch is in the OFF position.
  2. Jikọọ eriri ike enyere na ntinye AC dị na panel azụ nke oscilloscope ahụ.
  3. Tinye nsọtụ nke ọzọ nke eriri ike n'ime oghere ọkụ AC gbadoro ụkwụ.

2.3 Ike mbido

Press the power button located on the front panel. The oscilloscope will perform a self-test and boot up. The display will show the Tektronix logo followed by the main measurement interface.

2.4 Connecting Probes and Inputs

The MSO44 features FlexChannels, which can be configured as analog or digital inputs.

3. Ntuziaka ọrụ

3.1 Interface onye ọrụ gafereview

The oscilloscope features a 13.3-inch HD capacitive touchscreen display for intuitive operation. Key controls are also available via physical knobs and buttons on the right side of the display.

3.2 Nha Ndị Dị Mkpa

  1. Ntọala ọwa: Press the channel button corresponding to the input you wish to configure. Use the touchscreen or vertical scale knob to adjust vertical sensitivity (Volts/Div).
  2. Ntọala oge: Use the horizontal scale knob to adjust the time base (Seconds/Div) to view the desired number of cycles.
  3. Na-akpali: The trigger system stabilizes repetitive waveforms. Use the trigger level knob to set the trigger threshold. Select trigger type (Edge, Pulse, Runt, etc.) from the trigger menu on the screen.
  4. Ntụle: Access the 'Measure' menu to add automatic measurements such as frequency, peak-to-peak voltage, RMS, wdg.

3.3 Atụmatụ dị elu

4. Nlekọta

4.1 Na-ehicha akụrụngwa

To maintain the performance and appearance of your oscilloscope:

4.2 nhazi nhazi

The MSO44 is factory calibrated. For optimal performance, periodic calibration by a qualified service center is recommended. Refer to the Tektronix website or contact support for calibration services.

4.3 Nchekwa

When not in use for extended periods, store the oscilloscope in a clean, dry environment, away from direct sunlight and extreme temperatures. Use the original packaging or a suitable protective case.

5. Nchọpụta nsogbu

NsogbuIhe nwere ike imeNgwọta
Enweghị ngosi mgbe agbanyere ọkụPower cord not connected; Power outlet issue; Internal faultCheck power cord connection; Verify power outlet functionality; Contact Tektronix support
Enweghị ụdị ebili mmiri egosiriProbe not connected; Incorrect channel settings; Trigger not set correctly; Signal too small or largeEnsure probe is connected and functional; Check channel voltage/division settings; Adjust trigger level and type; Adjust vertical scale or input signal
Ụdị ebili mmiri na-adịghị akwụsi ikeImproper trigger settings; Noise in signal; Grounding issueAdjust trigger source, level, and slope; Use averaging or bandwidth limit; Ensure proper grounding of the oscilloscope and circuit
Ihuenyo mmetụ anaghị anabataTemporary software glitch; Screen calibration neededRestart the oscilloscope; Refer to the full manual for touchscreen calibration procedures

6. Nkọwapụta

The following table outlines the key technical specifications for the Tektronix MSO44 4-BW-200 Mixed Signal Oscilloscope.

NjirimaraNkọwapụta
Number of FlexChannels4
Bandwidth (all analog channels)200 MHz
Sample Rate (all analog/digital channels)6.25 GS/s (real-time)
Mkpebi Vetikal12 bits ADC (16 bits in High Resolution Mode)
Ngosipụta13.3 in. color HD (1920 x 1080) capacitive touchscreen
Ogologo ndekọ31.25 M points
Akụkụ ngwaahịa2.76 x 0.79 x 10.24 sentimita asatọ
Ibu Ibu48.75 pound

7. Akwụkwọ ikike na nkwado

7.1 Ozi akwụkwọ ikike

Tektronix products are backed by a standard warranty. For detailed information regarding the warranty period and terms for your MSO44 4-BW-200 oscilloscope, please refer to the warranty card included with your product or visit the official Tektronix websaịtị.

7.2 Nkwado nka na ụzụ

Should you encounter any issues or require technical assistance, please contact Tektronix customer support.

Akwụkwọ ndị emetụtara - MSO44 4-BW-200

Tupuview Tektronix 4 Series MSO Oscilloscope Specifications and Performance Verification
Comprehensive technical specifications and performance verification procedures for Tektronix 4 Series Mixed Signal Oscilloscopes (MSO), including models MSO44, MSO46, MSO44B, and MSO46B. This document details instrument capabilities and testing methods.
Tupuview Tektronix 4 Series MSO: MSO44, MSO46, MSO44B, MSO46B Specifications & Performance Verification
Detailed specifications and performance verification procedures for the Tektronix 4 Series MSO oscilloscopes, including models MSO44, MSO46, MSO44B, and MSO46B. Essential for understanding instrument capabilities and ensuring optimal performance.
Tupuview Tektronix 4 Series MSO: MSO44, MSO46, MSO44B, MSO46B Nkọwapụta na Nkwenye Arụmọrụ
Nkọwapụta zuru ezu na usoro nkwenye arụmọrụ maka oscilloscopes Tektronix 4 Series MSO (MSO44, MSO46, MSO44B, MSO46B), nke na-ekpuchi ọwa analog na dijitalụ, sistemụ mkpalite, na ule arụmọrụ dị mkpa.
Tupuview Tektronix 4 Series MSO Oscilloscope: Nkọwapụta na Nkwenye Arụmọrụ
Nkọwapụta zuru ezu na usoro nkwenye arụmọrụ maka oscilloscopes Tektronix 4 Series MSO, gụnyere ụdị MSO44, MSO46, MSO44B, na MSO46B. Na-ekpuchi ikike eletriki, oge, ihe mkpali, na nha.
Tupuview Tektronix 4 Series Mixed Signal Oscilloscopes Declassification and Security Instructions
Instructions for declassifying and sanitizing Tektronix 4 Series Mixed Signal Oscilloscopes (MSO44, MSO46) to ensure data security, covering procedures for working and non-functional instruments.
Tupuview Tektronix 4/5/6 Series MSO enyemaka enwere ike ibipụta: Ntuziaka onye ọrụ
Akwụkwọ ntuziaka onye ọrụ zuru oke maka Tektronix 4/5/6 Series Mixed Signal Oscilloscopes (MSO44, MSO46, MSO54, MSO56, MSO58, MSO58LP, MSO64), na-akọwapụta atụmatụ, nrụnye, ọrụ, na interface.