Leviton LB230-GF

Leviton LB230-GF 30A 2-Pole Plug-On GFCI Branch Circuit Breaker

Akwụkwọ ntuziaka

Okwu mmalite

This manual provides essential information for the safe and proper installation, operation, and maintenance of your Leviton LB230-GF 30A 2-Pole Plug-On GFCI Branch Circuit Breaker. This device is designed to provide overload and short-circuit protection, featuring an all plug-on design for ease of installation. It incorporates hydraulic magnetic precision trip technology and patented reset lockout technology for enhanced safety and reliability.

Ozi nchekwa

Ịdọ aka ná ntị: Risk of electric shock or electrocution. Improper installation or use can result in serious injury or death. Always disconnect power at the main service panel before working with electrical circuits. Installation should only be performed by a qualified electrician in accordance with all national and local electrical codes.

Ntọala na nwụnye

The Leviton LB230-GF circuit breaker features a revolutionary all plug-on design, allowing the entire load center to be wired at rough-in without circuit breakers installed. All hot and neutral wires terminate at custom lugs in the panel, not at the circuit breaker itself.

  1. Ịkwụsị ike: Before beginning any work, ensure the main power to the electrical panel is completely disconnected. Use a voltage tester to confirm the absence of power.
  2. Nkwadebe panel: Ensure the load center is properly wired according to local electrical codes, with hot and neutral wires terminated at the designated custom lugs.
  3. Ebe nbibi: Identify the appropriate slot in the load center for the 2-pole 30A GFCI breaker.
  4. Plug-On Installation: Align the circuit breaker with the bus bar and firmly press it into place until it is securely seated. The plug-on design ensures a reliable connection.
  5. Njikọ waya: Connect the load wires to the appropriate terminals on the circuit breaker. Ensure all connections are tight and secure.
  6. Ground and Neutral Connections: Verify that the ground and neutral wires are correctly connected within the panel as per the load center's instructions.
  7. Weghachi ike: Once installation is complete and all connections are verified, close the panel cover and restore power to the main service panel.
Leviton LB230-GF 30A 2-Pole Plug-On GFCI Branch Circuit Breaker

Image: Leviton LB230-GF 30A 2-Pole Plug-On GFCI Branch Circuit Breaker. This image shows the front view of the circuit breaker, highlighting its compact design and terminal connections.

Ntuziaka ọrụ

The Leviton LB230-GF circuit breaker is designed for intuitive operation and status indication.

Nlekọta

The Leviton LB230-GF circuit breaker requires minimal maintenance. Regular visual inspections are recommended.

Nchọpụta nsogbu

If the circuit breaker trips, follow these steps:

  1. Chọpụta mmejọ: Observe the LED indicators on the breaker to determine the type of fault (e.g., ground fault, arc fault, overload).
  2. Kwụpụ Ibu: Turn off or unplug all appliances and devices connected to the affected circuit.
  3. Tọgharia ihe nbibi: Push the breaker handle completely to the 'OFF' position, then firmly to the 'ON' position.
  4. Nwale sekit: If the breaker holds, gradually reconnect devices to identify the faulty appliance or overloaded condition.
  5. Njem na-adịgide adịgide: If the breaker trips immediately after resetting, or if the LEDs indicate a persistent fault, there may be a wiring issue or a severe fault in the circuit. In such cases, do not attempt further resets. Contact a qualified electrician for diagnosis and repair.
  6. Tọgharia mkpọchi: If the breaker will not reset, it may be due to the patented reset lockout technology, indicating that ground or arc fault protection is compromised. This is a safety feature. Do not attempt to bypass it. Contact a qualified electrician.

Nkọwapụta

ỤdịLeviton
Nọmba nlereanyaLB230-GF
Ogo dị ugbu a30 Amps
Ụdị ihe mgbawa sekitGFCI
Ụdị nkwụnyeUgwu Panel
Ọnụọgụ nke okporo osisi2
Voltage120/240 Volts AC
Ibu Ibu13.6 ounces
Akụkụ ngwaahịa3.1 x 2 x 3.9 sentimita asatọ
Ihe onwunweViton

Akwụkwọ ikike

This Leviton LB230-GF circuit breaker is covered by a Akwụkwọ ikike nke afọ 10. For detailed terms and conditions, please refer to the warranty documentation provided with your purchase or visit the official Leviton websaịtị.

Nkwado

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact Leviton customer support. You can find contact information on the official Leviton website or through your product's packaging.

Websaịtị: www.leviton.com

Akwụkwọ ndị emetụtara - LB230-GF

Tupuview Leviton GFNT1-DIN/GFNT2-DIN DIN Rail Ugwu GFCI Ntuziaka nwụnye
Ntuziaka zuru oke maka ịwụnye na ịnwale Leviton's GFNT1-DIN na GFNT2-DIN DIN Rail Mount GFCI nnabata, gụnyere ntuziaka wiring, kpachara anya nchekwa, na nchọpụta nsogbu.
Tupuview Nduzi Ntinye na Nnwale nke Leviton GFCI Receptacle
Nduzi zuru oke gbasara otu esi etinye ma nwalee Leviton SmartLock Pro GFCI Receptacle, gụnyere ntuziaka waya, ihe nchekwa, na ndụmọdụ gbasara nsogbu.
Tupuview Ntuziaka maka ntinye nke ebe a na-ebu ibu na Leviton
Ntuziaka ntinye zuru ezu maka Leviton Load Center Enclosures, ụdị LP2xx, LP3xx, LP4xx, na LP6xx. Na-ekpuchi nchekwa, iwepụ ihe mgbochi, itinye waya, ntinye ihe mgbawa alaka, na itinye mkpuchi.
Tupuview Leviton GFCI Outlet nwere ntinye ọdụ ụgbọ mmiri USB na akwụkwọ ntuziaka
Ntuziaka zuru oke maka ịwụnye na ịrụ ọrụ Leviton GFCI Outlets nwere ọdụ ụgbọ mmiri USB, gụnyere ntuziaka wiring, ịdọ aka ná ntị nchekwa, usoro ule na ozi akwụkwọ ikike.
Tupuview Installing and Testing Leviton Smart GFCI Outlet: A Comprehensive Guide
Step-by-step instructions for installing and testing Leviton Smart GFCI outlets (models D2GF1, D2GF2). Learn about GFCI functionality, wiring, troubleshooting, and safety precautions.
Tupuview Nduzi Ntinye na Nnwale Leviton SmartlockPro GFCI Receptacle
Nduzi zuru oke maka itinye na nnwale ihe nkwụnye Leviton SmartlockPro Ground Fault Circuit Interrupter (GFCI). Na-ekpuchi nchedo nchekwa, waya, nsogbu nchọpụta, na atụmatụ ngwaahịa.