Okwu mmalite
This manual provides essential information for the safe and proper installation, operation, and maintenance of your Leviton LB230-GF 30A 2-Pole Plug-On GFCI Branch Circuit Breaker. This device is designed to provide overload and short-circuit protection, featuring an all plug-on design for ease of installation. It incorporates hydraulic magnetic precision trip technology and patented reset lockout technology for enhanced safety and reliability.
Ozi nchekwa
Ịdọ aka ná ntị: Risk of electric shock or electrocution. Improper installation or use can result in serious injury or death. Always disconnect power at the main service panel before working with electrical circuits. Installation should only be performed by a qualified electrician in accordance with all national and local electrical codes.
- Ensure the main power supply is turned OFF before installation or servicing.
- Nyochaa voltage and current ratings of the circuit breaker match the application requirements.
- Ejila ngwaọrụ a ma ọ bụrụ na ọ dị ka ọ mebiri emebi.
- This GFCI circuit breaker features patented reset lockout technology and will not reset if ground or arc fault protection is compromised. Do not attempt to bypass this safety feature.
Ntọala na nwụnye
The Leviton LB230-GF circuit breaker features a revolutionary all plug-on design, allowing the entire load center to be wired at rough-in without circuit breakers installed. All hot and neutral wires terminate at custom lugs in the panel, not at the circuit breaker itself.
- Ịkwụsị ike: Before beginning any work, ensure the main power to the electrical panel is completely disconnected. Use a voltage tester to confirm the absence of power.
- Nkwadebe panel: Ensure the load center is properly wired according to local electrical codes, with hot and neutral wires terminated at the designated custom lugs.
- Ebe nbibi: Identify the appropriate slot in the load center for the 2-pole 30A GFCI breaker.
- Plug-On Installation: Align the circuit breaker with the bus bar and firmly press it into place until it is securely seated. The plug-on design ensures a reliable connection.
- Njikọ waya: Connect the load wires to the appropriate terminals on the circuit breaker. Ensure all connections are tight and secure.
- Ground and Neutral Connections: Verify that the ground and neutral wires are correctly connected within the panel as per the load center's instructions.
- Weghachi ike: Once installation is complete and all connections are verified, close the panel cover and restore power to the main service panel.

Image: Leviton LB230-GF 30A 2-Pole Plug-On GFCI Branch Circuit Breaker. This image shows the front view of the circuit breaker, highlighting its compact design and terminal connections.
Ntuziaka ọrụ
The Leviton LB230-GF circuit breaker is designed for intuitive operation and status indication.
- Mgbanyụ/ Gbanyụọ Ọrụ: To turn the circuit ON, push the handle firmly to the 'ON' position. To turn it OFF, push the handle firmly to the 'OFF' position.
- Trip Indication: In the event of an overload, short-circuit, or ground fault, the circuit breaker will trip, moving the handle to a central 'TRIPPED' position.
- Ihe ngosi LED: The breaker features color indicators in the handle and LEDs that communicate the trip condition and type of fault. These LEDs remain illuminated even when in a tripped state, allowing for easy identification of the fault type.
- Hydraulic Magnetic Technology: This precision trip technology ensures consistent operation across a wide temperature range, from -40°C to 85°C (-40°F to 185°F), without requiring re-rating.
Nlekọta
The Leviton LB230-GF circuit breaker requires minimal maintenance. Regular visual inspections are recommended.
- Nlele anya: Lelee ihe mgbawa sekit ahụ mgbe niile maka ihe ịrịba ama ọ bụla nke mmebi anụ ahụ, mgbanwe agba, ma ọ bụ njikọ ndị na-adịghị mma.
- Bọtịnụ ule: GFCI circuit breakers typically include a test button. Refer to the specific instructions on the breaker itself or the load center for recommended testing frequency (usually monthly). Pressing the test button should trip the breaker. If it does not, the breaker may be faulty and should be replaced by a qualified electrician.
- Nhicha: If necessary, gently wipe the exterior of the breaker with a dry, clean cloth. Do not use liquid cleaners or solvents.
Nchọpụta nsogbu
If the circuit breaker trips, follow these steps:
- Chọpụta mmejọ: Observe the LED indicators on the breaker to determine the type of fault (e.g., ground fault, arc fault, overload).
- Kwụpụ Ibu: Turn off or unplug all appliances and devices connected to the affected circuit.
- Tọgharia ihe nbibi: Push the breaker handle completely to the 'OFF' position, then firmly to the 'ON' position.
- Nwale sekit: If the breaker holds, gradually reconnect devices to identify the faulty appliance or overloaded condition.
- Njem na-adịgide adịgide: If the breaker trips immediately after resetting, or if the LEDs indicate a persistent fault, there may be a wiring issue or a severe fault in the circuit. In such cases, do not attempt further resets. Contact a qualified electrician for diagnosis and repair.
- Tọgharia mkpọchi: If the breaker will not reset, it may be due to the patented reset lockout technology, indicating that ground or arc fault protection is compromised. This is a safety feature. Do not attempt to bypass it. Contact a qualified electrician.
Nkọwapụta
| Ụdị | Leviton |
| Nọmba nlereanya | LB230-GF |
| Ogo dị ugbu a | 30 Amps |
| Ụdị ihe mgbawa sekit | GFCI |
| Ụdị nkwụnye | Ugwu Panel |
| Ọnụọgụ nke okporo osisi | 2 |
| Voltage | 120/240 Volts AC |
| Ibu Ibu | 13.6 ounces |
| Akụkụ ngwaahịa | 3.1 x 2 x 3.9 sentimita asatọ |
| Ihe onwunwe | Viton |
Akwụkwọ ikike
This Leviton LB230-GF circuit breaker is covered by a Akwụkwọ ikike nke afọ 10. For detailed terms and conditions, please refer to the warranty documentation provided with your purchase or visit the official Leviton websaịtị.
Nkwado
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact Leviton customer support. You can find contact information on the official Leviton website or through your product's packaging.
Websaịtị: www.leviton.com