1. Okwu mmalite
This manual provides essential information for the safe and efficient operation of your COTEK SP-4000-124 Pure Sine Wave Inverter. This high-frequency inverter is designed to convert 24VDC battery power into 120VAC household electricity, offering a pure sine wave output suitable for sensitive electronics. Please read this manual thoroughly before installation and use.
2. Ntuziaka nchekwa
Adherence to these safety guidelines is crucial to prevent personal injury and damage to the inverter or connected equipment.
- Installation must be performed by qualified personnel in accordance with all applicable electrical codes.
- Do not expose the inverter to rain, moisture, or extreme temperatures.
- Gbaa mbọ hụ na ikuku ventilashị kwesịrị ekwesị na gburugburu inverter iji gbochie ikpo oke ọkụ.
- Connect the inverter only to a 24VDC power source. Connecting to a different voltage nwere ike ịkpata mmebi.
- Always disconnect the DC power source before performing any maintenance or wiring.
- Hụ na inverter ahụ dị n'ala nke ọma.
- Emeghela inverter casing. Enweghị akụkụ ndị ọrụ ga-arụ ọrụ n'ime.
3. Akụrụngwa Ngwaahịa
The COTEK SP-4000-124 Inverter incorporates advanced features for reliable power conversion:
- Pure sine wave output for compatibility with all AC loads.
- Power ON/OFF remote control capability via green terminal.
- Input and output are fully isolated for enhanced safety.
- Temperature and load-controlled cooling fan for optimal thermal management.
- Njikọta dị mfe iji yana ihe ngosi ọnọdụ LED agba 3.
- Output frequency (50/60 Hz) selectable via DIP switch.
- Mmepụta voltage nwere ike ịhọrọ site na mgbanwe DIP.
- Power saving mode adjustable by variable resistor.
- Comprehensive input protection: Reverse Polarity (Fuse), Under Voltage, karịrị Voltage.
- Robust output protection: Short Circuit, Overload, Over Temperature.
- Type 1 Indoor Aluminum Enclosure.
- E13 / UL / CE / FCC approved.
4. Ngwaahịa gafereview
Familiarize yourself with the physical components and connections of your inverter.

This image displays the COTEK SP-4000-124 Pure Sine Wave Inverter, showcasing its robust blue casing and overall design from an elevated, angled perspective.

This image shows the rear panel of the COTEK SP-4000-124 Inverter, featuring the hardwire AC output terminal, the main power switch, and a set of LED status indicators and DIP switches for configuration.

The front panel of the COTEK SP-4000-124 Inverter is depicted, highlighting the robust DC input terminals (red for positive, black for negative) and the chassis ground connection point.

This technical drawing provides detailed mechanical dimensions and outlines of the COTEK SP-4000 series inverter from multiple perspectives (top, front, side), indicating measurements in both millimeters and inches.
5. Ntọala na nwụnye
Proper installation is critical for the performance and safety of the inverter. It is highly recommended that installation be performed by a certified electrician or qualified technician.
5.1 Na-arịgo
- Họrọ ebe kpọrọ nkụ, ebe ikuku na-abata nke ọma, ma dịkwa jụụ.
- Mount the inverter securely to a stable surface, ensuring adequate clearance for airflow around the cooling fins.
- Avoid mounting near flammable materials or in direct sunlight.
Njikọ ntinye DC 5.2
- Ensure the DC power source (battery bank) is rated for 24VDC.
- Use appropriately sized cables to minimize voltage drop and ensure safe current handling.
- Connect the positive (+) terminal of the inverter to the positive terminal of the battery bank.
- Connect the negative (-) terminal of the inverter to the negative terminal of the battery bank.
- Install an external DC fuse or circuit breaker between the battery and the inverter for protection.
5.3 Njikọ mmepụta AC
- The inverter features a hardwire AC outlet. Connect your AC loads directly to this terminal.
- Ensure all AC wiring complies with local electrical codes.
- Do not exceed the inverter's rated output power.
5.4 Mgbanwe
- Connect the inverter's chassis ground terminal to a reliable earth ground point.
6. Ntuziaka ọrụ
6.1 Gbanyụọ/ gbanyụọ
- After all connections are secure, switch on the external DC circuit breaker (if installed).
- Locate the main power switch on the inverter's rear panel and switch it to the 'ON' position.
- The LED indicators will illuminate, indicating the inverter's status.
- To power off, switch the main power switch to 'OFF', then disconnect the DC power source.
6.2 LED egosi
The 3-color LED indicators provide visual feedback on the inverter's operational status and any potential faults.
- Akwụkwọ ndụ akwụkwọ ndụ: Arụ ọrụ nkịtị.
- Edo edo: Warning (e.g., low battery, overload warning). Refer to troubleshooting.
- Uhie: Fault (e.g., overload shutdown, over-temperature shutdown). The inverter will shut down.
6.3 Output Frequency and Voltage Nhọrọ
The inverter allows for selection of output frequency (50/60 Hz) and voltage via DIP switches. Consult the label near the DIP switches for specific settings. Ensure the inverter is off before adjusting DIP switches.
7. Nlekọta
Mmezi mgbe niile na-eme ka arụmọrụ kachasị mma na ogologo ndụ nke inverter gị dịgide.
- Nhicha: Periodically clean the exterior of the inverter and ensure cooling vents are free from dust and debris. Use a dry, soft cloth. Do not use liquid cleaners.
- Njikọ: Annually inspect all DC and AC connections for tightness and corrosion. Loose connections can cause overheating and poor performance.
- gburugburu: Gbaa mbọ hụ na gburugburu ebe ọrụ ka dị n'ime oke okpomọkụ na iru mmiri akọwapụtara.
8. Nchọpụta nsogbu
Akụkụ a na-enye nduzi maka okwu nkịtị. Maka nsogbu dị mgbagwoju anya, kpọtụrụ ndị ọrụ ruru eru.
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| No AC output, Red LED on | Overload, Over-temperature, Input over/under voltage | Reduce load, allow cooling, check battery voltage. Cycle power. |
| Ikanam edo edo agbanyere | Obere batrị voltage warning, minor overload warning | Charge batteries, reduce load. |
| Inverter anaghị agbanyụ | No DC input power, loose connections, blown DC fuse | Check battery connections, verify battery voltage, inspect DC fuse/breaker. |
| AC output unstable | Poor DC input connections, excessive load, faulty AC wiring | Tighten DC connections, reduce load, inspect AC wiring. |
9. Nkọwapụta
Detailed technical specifications for the COTEK SP-4000-124 Pure Sine Wave Inverter.

A table detailing the technical specifications of the COTEK SP4000-124 inverter, including output voltage, frequency, waveform, continuous power, surge power, input voltage, efficiency, operating temperature range, dimensions, and weight.
| Oke | Uru |
|---|---|
| Mmepụta Voltage | 120 Volts AC, +/- 5% |
| Ugboro mmepụta | 60 Hz |
| Mmepụta Waveform | Okpokoro nke Sine |
| Ike na-aga n'ihu | 4000 Watt |
| Ike ịwa ahụ | 8000 VA |
| Ntinye Voltage | 24 volts DC |
| Ntinye Voltage Oke | 21.0 ruo 33.0 volts DC |
| Peak Efficiency at Full Load | 91% |
| Normal Operating Temp. Range | -20°C to 60°C (-4°F to 140°) |
| Full Load Operating Temp. Range | -20°C to 40°C (-4°F to 104°) |
| Akụkụ (L x W x H) | 18.66 x 12.56 x 9.53 sentimita (474 x 319 x 242 mm) |
| Ibu | 24.8 pound (11.25 n'arọ) |
10. Akwụkwọ ikike na nkwado
For warranty information and technical support, please refer to the documentation provided with your purchase or contact COTEK customer service directly. Keep your purchase receipt as proof of purchase for warranty claims.