1. Ngwaahịa gafereview
The IBO OHI 25-60/180 circulation pump, also known as a heating pump, facilitates the movement of heating water within a heating system. This pump model features a manual 3-speed regulator, allowing for system adaptation. It is suitable for use in heating and air conditioning systems with fluid temperatures ranging from +2°C to +110°C.
Atụmatụ gụnyere:
- Manual 3-speed regulator for optimal system adaptation.
- Suitable for heating and air conditioning systems with fluid temperatures from +2°C to +110°C.
- Constructed with a ceramic shaft, graphite radial bearing, stainless steel bearing plate and rear pot, and a grey cast iron pump housing.
- Nhazi dị obere maka ntinye dị mfe.
- Ọrụ juu.

Image 1: IBO OHI 25-60/180 Circulation Pump. This image displays the orange-colored pump unit with its black control panel, showing the speed selector and technical specifications. Two black rubber seals are visible at the bottom.
2. Ozi nchekwa
Read all instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Nchekwa Eletriki: Ensure the power supply is disconnected before any installation, maintenance, or repair work. All electrical connections must be performed by a qualified electrician in accordance with local regulations. The pump requires a 230V, 50Hz power supply.
- Okpomọkụ mmiri: The pump handles fluid temperatures between +2°C and +110°C. Exercise caution when working with hot water to prevent burns.
- Nrụgide: The maximum operating pressure is 10 bar. Ensure the system components can withstand this pressure.
- Gburugburu nwụnye: Install the pump in a dry, well-ventilated area, protected from frost and direct weather exposure.
- Ngwa nchekwa nkeonwe: Always wear appropriate personal protective equipment (e.g., gloves, safety glasses) during installation and maintenance.
3. Ntuziaka nwụnye
Proper installation is crucial for the pump's efficient and safe operation.
3.1 Nyochaa nwụnye tupu etinye ya
- Verify that the pump's specifications (voltage, frequency, pressure) match your system requirements.
- Ensure the installation location provides adequate space for mounting and future maintenance.
- Confirm that the piping system is clean and free of debris.
3.2 Ịkwanye mgbapụta
- The pump has an installation length of 180 mm. Ensure sufficient space between pipe connections.
- Install the pump in the return line of the heating system, if possible, to extend its lifespan by operating at lower temperatures.
- Ensure the motor shaft is horizontal to allow for proper lubrication of the bearings.
- Use the provided seals (gaskets) to ensure a watertight connection to the piping. The connection diameter is 1 1/2"/1".
- Tighten all connections securely but avoid over-tightening.
3.3 Njikọ eletrik
- Gbaa mbọ hụ na agbanyụrụ isi ọkụ eletrik na mgbanyụ sekit.
- Connect the pump to a 1 x 230 V, 50 Hz power supply.
- The pump has an IP44 protection rating. Ensure the electrical connections are protected from moisture.
- Follow the wiring diagram provided on the pump's terminal box cover.
- Gbaa mbọ hụ na ntọ ala kwesịrị ekwesị.
3.4 System Filling and Venting
- After installation, fill the heating system with water.
- Vent the system thoroughly to remove any trapped air. Air in the system can cause noise and reduce pump efficiency.
- The pump may have a manual vent screw; open it carefully until water flows out, then close it.
4. Ntuziaka ọrụ
The IBO OHI 25-60/180 pump features a manual 3-speed selector to adjust performance.
4.1 Mmalite mbụ
- Ensure the system is filled with water and properly vented.
- Turn on the main power supply to the pump.
- Select a speed setting using the rotary switch on the pump's control panel.
4.2 Ntọala Ọsọ
The pump offers three speed levels, each with different power consumption, maximum flow rate (Q max), and maximum head (H max):
- Ọkwa I: 46 W power consumption, 22 l/min maximum flow, 3 m maximum head.
- Ọkwa II: 63 W power consumption, 38 l/min maximum flow, 5 m maximum head.
- Ọkwa III: 93 W power consumption, 55 l/min maximum flow, 6 m maximum head.
Adjust the speed setting based on the heating system's requirements to achieve optimal circulation and energy efficiency.
5. Nlekọta
Regular maintenance ensures the longevity and efficient operation of your circulation pump.
5.1 Nlele Oge Nile
- Nlele anya: Periodically check the pump for any signs of leaks, corrosion, or damage to the casing or electrical connections.
- Ọkwa mkpọtụ: Listen for any unusual noises during operation, which could indicate air in the system or a mechanical issue.
- Okpomọkụ: Ensure the pump is not overheating.
5.2 Nhicha
Keep the exterior of the pump clean and free from dust and debris to ensure proper heat dissipation.
5.3 Mmezi oge oyi (ọ bụrụ na ọdabara)
If the heating system is to be shut down for an extended period in freezing temperatures, ensure the system, including the pump, is drained to prevent frost damage.
6. Nchọpụta nsogbu
This section provides guidance for common issues. For complex problems, consult a qualified technician.
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Mgbapụta anaghị ebido | No power supply; Motor seized; Faulty wiring | Check power connection and circuit breaker; Manually turn rotor if accessible (after disconnecting power); Inspect wiring for damage. |
| Insufficient flow or no circulation | Air in the system; Blockage in pipes or pump; Incorrect speed setting | Vent the heating system thoroughly; Check for blockages; Adjust to a higher speed setting. |
| Pump na -ada ụda | Air in the system; Cavitation; Foreign objects in pump; Incorrect mounting | Vent the system; Check system pressure; Inspect pump for debris; Ensure horizontal motor shaft. |
| Ntanye na njikọ | Njikọ ndị mebiri emebi; | Tighten connections; Replace seals. |
7. Nka na ụzụ nkọwa
| Nọmba nlereanya | OHI25-60_180 |
| Ụdị | IBO |
| Voltage | 230 volts |
| Ugboro ugboro | 50 Hz |
| Power Consumption (3 levels) | I: 46 W; II: 63 W; III: 93 W |
| Max Flow Rate (3 levels) | I: 22 l/min; II: 38 l/min; III: 55 l/min |
| Max Head (3 levels) | I: 3 m; II: 5 m; III: 6 m |
| Ụdị Nchedo | IP44 |
| Oke arụrụ ọrụ | 10 mmanya |
| Oke okpomọkụ mmiri mmiri | +2°C ruo +110°C |
| Installation Length | 180 mm |
| Dayameta njikọ | 1 1/2" / 1" |
| Akụrụngwa | Ceramic shaft, Graphite radial bearing, Stainless steel bearing plate and rear pot, Grey cast iron pump housing |
| Onye nrụpụta | 4U-Onlinehandel |
| Akụkụ ngwugwu | 20 x 14.2 x 13.8 cm |
| Ibu | 2.63 n'arọ |
| Koodu Akụkọ Mba Nile | 05902944507971 |
8. Akwụkwọ ikike na nkwado
Information regarding the product warranty is not provided in the available data. For warranty claims, technical support, or spare parts inquiries, please contact the original seller or the manufacturer, 4U-Onlinehandel, directly. Keep your purchase receipt as proof of purchase.