1. Ngwaahịa gafereview
The Chemtronics ES1210 Electro-Wash PX is a fast-drying, one-step precision cleaning and degreasing agent. It is formulated to be safe for most plastics. Engineered with very low surface tension, this high-pressure aerosol formulation effectively flushes areas clean and evaporates instantly, leaving no residue. It is an extra-strength, general-purpose cleaner/degreaser.

Foto 1: N'ihu view of the Chemtronics ES1210 Electro-Wash PX aerosol can, showing the product name, brand, and key features like "Plastic Safe" and "Xtra Strength".
2. Ozi Nchekwa na Ihe Ndị Na-akpachara Anya
DANGER! EXTREMELY FLAMMABLE.
Direct inhalation of spray may be harmful. Container may explode if heated. Read precautions on back panel before use.
- Enwere ike ire ọkụ: Chebe ọkụ, ebe dị ọkụ, ọkụ, ọkụ mepere emepe na ebe mgbanye ndị ọzọ. Anaghị ese anwụrụ.
- Pressurized Container: Do not pierce or burn, even after use. Do not spray on an open flame or other ignition source.
- Kpọtụrụ anya: Causes serious eye irritation. Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists, get medical attention.
- kọntaktị akpụkpọ: Wash hands thoroughly after handling. If skin irritation occurs, get medical advice/attention.
- iku ume: Direct inhalation of spray may be harmful. Use only in a well-ventilated area. If inhaled, move person to fresh air and restore breathing. If breathing is difficult, give oxygen. Get medical attention immediately.
- Nchekwa: Protect from sunlight. Do not expose to temperatures exceeding 50°C/122°F. Store in a well-ventilated place. Keep container tightly closed.
- mkpofu: Tụfuo ihe dị n'ime / akpa dịka iwu mpaghara / mpaghara / mba / mba ụwa si dị.
- Debe ebe ụmụaka na-apụghị iru.
For industrial use only. Read Safety Data Sheets (SDS) prior to use. For SDS or technical data sheets, contact Chemtronics Technical Hot Line at 1-800-TECH-401 (1-800-832-4401) or visit their websaịtị na www.chemtronics.com.

Foto nke atọ: Azụ view of the Chemtronics ES1210 aerosol can, displaying detailed usage directions and critical safety warnings in multiple languages.

Foto 3: Akụkụ view of the Chemtronics ES1210 aerosol can, providing further safety information, ingredient list, manufacturer contact details, and a barcode.
3. Nhazi na Nkwadebe
- Gbaa mbọ hụ na mpaghara ọrụ nwere ikuku nke ọma.
- Wear appropriate personal protective equipment (PPE), including safety glasses and gloves, to prevent eye and skin contact.
- Identify the object to be cleaned. Ensure it is powered off and cooled down if applicable.
- Shake the can gently before use.
- Attach the extension tube to the nozzle for precision application, if required.
4. Ntuziaka ọrụ
Follow these steps for effective cleaning and degreasing:
- Hold the object to be cleaned in a vertical position.
- Hold the aerosol can 4-6 inches (10-15 cm) from the surface of the object.
- Spray from top to bottom, allowing the liquid to flush away contaminants.
- For precision application or reaching confined areas, utilize the provided extension tube.
- Allow the product to evaporate completely. It is designed to evaporate instantly, leaving no residue.
Note: This product is safe on most plastics. Always test on an inconspicuous area first if unsure about material compatibility.
5. Nchekwa na Nlekọta
Proper storage ensures product longevity and safety:
- Store in a cool, dry, well-ventilated area.
- Keep away from direct sunlight and temperatures exceeding 50°C (122°F).
- Keep container tightly closed when not in use.
- Do not store near heat sources, sparks, or open flames.
No specific maintenance is required for the aerosol can itself.
6. Troubleshooting and First Aid
In case of accidental exposure or misuse, refer to the following:
- Kpọtụrụ anya: Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention immediately.
- kọntaktị akpụkpọ: Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Continue to rinse for at least 10 minutes. Get medical attention if irritation develops.
- iku ume: If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention immediately.
- Ntinye: Do not induce vomiting. Never give anything by mouth to an unconscious person. Get medical attention immediately.
- Ọkụ: In case of fire, use dry chemical, CO2, water spray (fog), or foam. Do not use water jet.
For further assistance, consult the Safety Data Sheet (SDS) or contact emergency services.
7. Nkọwapụta
| Njirimara | Nkọwa |
|---|---|
| Nọmba nlereanya | ES1210 |
| Ụdị | Chemtronic |
| Ụdị ihe | Liquid, Aerosol |
| Njirimara ihe | Organic |
| Olu ihe | 12.5 Fluid Ounces (354 g) |
| Akụkụ ngwugwu | 9.21 x 1.65 x 1.57 sentimita asatọ |
| Onye nrụpụta | ITW Chemtronics |
| Plastic Safe | Ee |
| Ịkụ ọkụ | Na-agba ọkụ nke ukwuu |

Image 4: A visual representation of the Chemtronics ES1210 aerosol can's size, indicating a height of approximately 10 inches (25 cm) when held by a hand.
8. Akwụkwọ ikike Ozi
For specific warranty details regarding the Chemtronics ES1210 Electro-Wash PX, please refer to the official Chemtronics websaịtị ma ọ bụ kpọtụrụ ndị ahịa ha ozugbo. Usoro na ọnọdụ akwụkwọ ikike nwere ike ịdị iche.
9. Nkwado na Ozi kọntaktị
For technical assistance, product inquiries, or safety data sheets, please contact Chemtronics:
- Technical Hot Line: 1-800-TECH-401 (1-800-832-4401)
- Websaịtị: www.chemtronics.com
- adreesị: Chemtronics, 8125 Cobb Center Dr., Kennesaw, Georgia USA 30152-4388
For 24-hour emergency support, call CHEMTREC at 1-800-424-9300 (or +1 703-527-3887 for collect calls).