Wilo 4105032

Wilo 4105032 Star S 21F Three Speed Wet Rotor Hydronic Circulating Pump Instruction Manual

1. Okwu mmalite

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Wilo 4105032 Star S 21F Three Speed Wet Rotor Hydronic Circulating Pump. This pump is designed for use in hot-water heating systems, industrial circulation systems, cold-water systems, and air-conditioning systems. It is not approved for use with domestic hot water. The pump features a bronze volute and a wet rotor design.

2. Ozi nchekwa

Please read and understand all safety instructions before installing or operating the pump. Failure to follow these instructions may result in personal injury, property damage, or electric shock.

  • Nchekwa Eletriki: Ensure the power supply is disconnected before any installation or maintenance work. All electrical connections must be performed by a qualified electrician in accordance with local and national electrical codes. The pump operates on 115-Volt, 60Hz power.
  • Nchekwa nrụgide: The maximum working pressure for this pump is 145 PSI. Do not exceed this pressure.
  • Nchekwa okpomọkụ: The pump is designed for a temperature range of 14°F to 230°F. Ensure system temperatures remain within this range.
  • Nwụnye: The pump can be installed in any position where the shaft is horizontal. Improper installation can lead to malfunction or damage.
  • Izugbe: Do not operate the pump dry. Ensure the system is filled with fluid before starting.

3. Ngwaahịa gafereview

The Wilo Star S 21F is a three-speed circulating pump designed for hydronic systems. It features a robust construction and a user-selectable speed setting to optimize performance and energy consumption.

Wilo Star S 21F Three Speed Wet Rotor Hydronic Circulating Pump
An image showing the Wilo Star S 21F circulating pump. The pump is green with a black electrical connection box and a red speed selector switch. The label on the pump body displays model information and technical specifications.

Isi ihe:

  • Ụlọ mgbapụta: Green-colored body, typically bronze volute.
  • moto: Wet rotor design, 115-Volt, 60Hz.
  • Ngbanwe Nhọrọ Ọsọ: Red rotary switch on the electrical box for selecting one of three speeds.
  • Electrical Connection Box: Black enclosure for wiring connections.
  • Flange Connections: Standard connections for system integration.

4. Ntọala na nwụnye

Ntinye kwesịrị ekwesị dị oke mkpa maka arụmọrụ nke ọkpọkọ ahụ na ogologo oge ya.

  1. Nkwadebe Sistemu: Ensure the heating or cooling system is drained and clean before installation.
  2. Ọnọdụ nkwụnye: The pump can be installed in any position, provided the motor shaft remains horizontal. This is critical for proper lubrication and cooling of the wet rotor.
  3. Njikọ ọkpọkọ: The pump uses 3/4-inch to 1-1/2-inch standard flanges. Use appropriate gaskets (typically supplied with the pump) and ensure a watertight seal. Avoid overtightening the flange bolts.
  4. Ọkụ eletrik:
    • Disconnect power at the main breaker before beginning any wiring.
    • Open the electrical connection box.
    • The pump features quick and easy wire connectors. To insert wires, displace the white tabs 90 degrees to open the holes. Insert the stripped wires and then return the tabs to their original position to secure the connection.
    • Connect the pump to a dedicated 115-Volt, 60Hz circuit. Ensure proper grounding.
    • Close the electrical connection box securely.
  5. Njuputa sistemu: After installation, slowly fill the system with fluid, ensuring all air is purged from the pump and piping. Air in the system can cause noise and damage to the pump.

5. Ntuziaka ọrụ

The Wilo Star S 21F pump offers three selectable speeds to match system requirements.

  1. Ike Na: Once the pump is installed and the system is filled, restore power to the circuit.
  2. Nhọrọ ọsọ ọsọ: Locate the red rotary switch on the electrical connection box. This switch allows you to select one of three operating speeds:
    • Speed 1 (Eco): Lowest power consumption (55W), suitable for minimal flow requirements.
    • Ọsọ 2: Medium power consumption (77W), for moderate flow.
    • Speed 3 (Max): Highest power consumption (98W), for maximum flow and head.
    Rotate the switch to the desired speed setting. The pump will begin operation at the selected speed.
  3. Nleba anya: Observe the system for proper circulation and listen for any unusual noises.

6. Nlekọta

The Wilo Star S 21F is designed for minimal maintenance. However, periodic checks can ensure optimal performance and extend its lifespan.

  • Nyocha kwa afọ: Annually inspect the pump for any signs of leaks, corrosion, or unusual wear.
  • System Fluid Quality: Ensure the system fluid is clean and free of debris. Contaminants can reduce pump efficiency and lifespan.
  • Njikọ eletrik: Periodically check electrical connections for tightness and signs of overheating. Disconnect power before checking.
  • Nchacha ikuku: If the pump becomes noisy, it may indicate air in the system. Follow system-specific procedures to purge air.

7. Nchọpụta nsogbu

Rụtụ aka na tebụl dị n'okpuru maka okwu nkịtị na ihe ngwọta ha nwere ike ime.

NsogbuIhe nwere ike imeNgwọta
Mgbapụta anaghị ebidoNo power; faulty wiring; seized impellerCheck power supply and circuit breaker. Verify electrical connections. Consult a qualified technician if impeller is seized.
Pump na -ada ụdaAir in system; cavitation; foreign object in pumpPurge air from the system. Check system pressure. Inspect pump for obstructions (disconnect power first).
Ezughị oke erubaIncorrect speed setting; air in system; clogged filter; undersized pumpIncrease speed setting. Purge air. Check and clean system filters. Verify pump sizing for application.
Mgbapụta na-agbapụtaLoose connections; damaged gaskets; cracked housingTighten flange connections. Replace damaged gaskets. If housing is cracked, pump replacement may be necessary.

8. Nkọwapụta

NkọwapụtaUru
ỤdịWilo
Nọmba nlereanya4105032 (Typ Star S 21 FX)
Voltage115 volts
Ugboro ugboro60 Hz
Maximum Current (I max)0.70 A
Oriri Ike (W)Speed 3: 98W, Speed 2: 77W, Speed 1: 55W
Ọnụego nfe kachagalọn 21 kwa nkeji
Ogologo Ibuli Kachasị Elu (Isi)21 ụkwụ
Oke okpomọkụ14°F ruo 230°F (-10°C ruo 110°C)
Nrụgide arụ ọrụ kacha145 PSI
Ihe onwunweStainless Steel (shaft), Bronze (volute)
Ibu Ibu7.08 pound (3.22 n'arọ)
Nha Flange3/4-Inch - 1-1/2-Inch standard flange
Klas mkpuchiCSA enclosure 2
Klas mkpuchiKlas F

9. Akwụkwọ ikike na nkwado

Wilo provides a 3-year limited warranty from the date of purchase for Residential Business Services products. For warranty claims, technical support, or further assistance, please contact Wilo customer service or your authorized dealer.

Akwụkwọ ndị emetụtara - 4105032

Tupuview Wilo-Star RS, RSD, ST, RSG, AC na-ekesa mgbapụta nwụnye na ntuziaka ọrụ
Nrụnye zuru oke na ntuziaka ọrụ maka Wilo-Star RS, RSD, ST, RSG, AC na-ekesa nfuli, na-ekpuchi ozi izugbe, nchekwa, njem, nkọwa, mgbakọ, ntinye, njikọ eletriki, ọrụ, mmezi, na nchọpụta nsogbu.
Tupuview Wilo Star Residential Wet Rotor Circulators: Installation and Operating Instructions
Comprehensive installation and operating instructions for Wilo Star Residential Wet Rotor Circulators. Covers safety, technical data, installation, electrical connection, startup, maintenance, and troubleshooting.
Tupuview Wilo-Star RS, RSD, ST, RSG, AC nwụnye na ntuziaka ọrụ
Ntuziaka zuru oke maka nrụnye, ịrụ ọrụ na nrụzi nke Wilo-Star RS, RSD, ST, RSG, na AC nfuli na-ekesa. Na-ekpuchi nchekwa, nkọwa teknụzụ, mgbakọ, njikọ eletrik, ọrụ, nchọpụta nsogbu, na akụkụ mapụtara.
Tupuview Wilo-Star-Z 15 Installation and Operating Instructions
This document provides comprehensive installation, operation, and maintenance guidance for the Wilo-Star-Z 15 circulating pump. It includes safety warnings, technical specifications, intended use, troubleshooting steps, and contact information for Wilo USA and Wilo Canada.
Tupuview Wilo-Star RS, RSD, ST, RSG, AC na-ekesa mgbapụta nwụnye na ntuziaka ọrụ
Nrụnye zuru oke na ntuziaka ọrụ maka usoro nfuli na-ekesa Wilo-Star RS, RSD, ST, RSG na AC. Na-ekpuchi ozi izugbe, ntuziaka nchekwa, ụgbọ njem, nchekwa, nkọwa mgbapụta, ngwa, mgbakọ, njikọ eletriki, ọrụ, mmezi, nchọpụta nsogbu na akụkụ mapụtara.
Tupuview Wilo-Star-Z/-ZD Einbau- na Betriebsanleitung
Umfassende nrụnye- na Betriebsanleitung für die Wilo-Star-Z/-ZD Zirkulationspumpen, inklusive Sicherheitshinweisen, technischen Daten na Wartungsanleitungen.