iDock Link 2 Advanced I/O Controller User Manual

iDock-LOGO

iDock Link 2 Advanced I/O Controller

iDock-Link-2-Advanced-I-O-Controller-PRODUCT

Recognize Precautionary Information
The Safety-Alert Symbol is a graphic representation intended to convey a safety message without the use of words. When you see this symbol, be alert to the possibility of death or serious injury. Follow the instructions in the safety message panel.

  • DANGER: The use of the word DANGER signifies the presence of an extreme hazard or unsafe practice which will most likely result in death or severe injury.
  • WARNING: The use of the word WARNING signifies the presence of a serious hazard or unsafe practice which could result in death or serious injury.
  • CAUTION: The use of the word CAUTION signifies possible hazard or unsafe practice which could result in minor or moderate injury.
  • NOTICE: The use of the word NOTICE indicates information considered important, but not hazard-related, to prevent machine or property damage.

General Operational Precautions

iDock-Link-2-Advanced-I-O-Controller- (1)

  • Read and understand the Owner’s/User’s Manual and become thoroughly familiar with the equipment and its controls before operating the equipment.
  • Never operate dock equipment while a safety device or guard is removed or disconnected.
  • Never remove DANGER, WARNING, or CAUTION signs, Placards or Decals on the equipment unless replacing them.

Learn the safe way to operate this equipment. Read and understand the manufacturer’s instructions. If you have any questions, ask your supervisor.

  • Only trained personnel should operate the dock leveler and vehicle restraint.
  • DO NOT use a broken or damaged dock leveler or vehicle restraint. Make sure proper service and maintenance procedures have been performed on the equipment before operating.
  • Transport vehicle wheels must be chocked unless the vehicle restraint is used. Never remove the wheel chocks until loading/unloading is finished and transport vehicle driver has been given permission to leave

CAUTION
The Link 2 is designed and intended to monitor loading dock availability for warehouse management systems. Do not rely solely on this device for safe loading dock operations. Always verify the transport vehicle is properly restrained via wheel chock or other restraining device/method.

iDock-Link-2-Advanced-I-O-Controller- (19)

INTRODUCTION

General Information

  • This manual provides current information on the iDock Link 2. Due to ongoing product improvement, some parts may have changed, along with operation and troubleshooting methods. This manual describes these changes where applicable.
  • The Link 2 is a technologically advanced I/O controller, designed to monitor loading dock activity and provide analytics for warehouse management.
  • Link 2 Controllers feature a modular design. A 3-in-1 inside light assembly shows the state of the system and loading dock availability. LED indicators show status of controller and connectivity. A key switch is provided to override communication lights and enable/disable dock availability. Each Link 2 has been factory tested to ensure satisfactory operation.
  • To illustrate which connections are to be made in the field at installation, electrical drawings are included with each order or by contacting Systems, LLC Technical Services.
  • Technical Service: Call 800-643-5424 or email techservices@loadingdocksystems.com

iDock-Link-2-Advanced-I-O-Controller- (18)

Component Identification
Inspect package and all components. Ensure enclosure, lenses, push button membranes, wiring and circuit boards are intact. Report any scratches, dents, damage or missing items immediately and note on the shipping Bill Of Lading (BOL).

  • iDock-Link-2-Advanced-I-O-Controller- (17)A — Multi-Colored LED Light
  • B — Enclosure*
  • C — Main Board, I/O
  • D — Membrane Ribbon Cable
  • E — Power Supply
  • F — Key Switch*

Definitions
Throughout this manual, different system indicators and functions of the iDock Link 2 are referenced. This section defines these indicators/functions:

  • (A) Power LED – Indicates the controller is receiving power.
  • (B) Network LED – Indicates connected status of the controller.
  • (C) Multi-Color LED – Multicolor LED that communicates system status for operator safety.
  • (D) Key Switch (Blocked Mode)

iDock-Link-2-Advanced-I-O-Controller- (16)

Assemble Mounting Feet

iDock-Link-2-Advanced-I-O-Controller- (15)

INSTALLATION

Drilling the Enclosure – Field Wiring
The enclosure has designated zones for field wire entry. Zones on top and bottom of enclosure are marked with a decal. Only drill in these zones, or damage to internal components may occur (A and B below).

Wiring Notes

  • Incoming power wires must be no smaller than 14 AWG. Ensure sufficient gauge for length of run from source.
  • Do not bundle wires over antenna (E)

iDock-Link-2-Advanced-I-O-Controller- (14)

A Top Hole Location D Incoming Power Plug G Input Terminals
B Bottom Hole Location E Antenna H 24V Terminals
C Wire Routing Channel F Outside Light Terminals J 0V Terminals

Installation Precautions

DANGER
Make sure that the power source has been locked out and tagged according to OSHA regulations and approved local electrical codes.

WARNING

  • A hard hat or other applicable head protection should always be worn when working under or around a dock leveler.
  • Always stand clear of platform lip when working in front of the dock leveler.

CAUTION

  • All electrical work — including the installation of the disconnect panel, control panel, and final connections to the pit junction box — must be performed by a certified electrician and conform to all local and applicable national codes.
  • Overhead door operators capable of remote operation can bypass iDock controller door interlock(s) when operated remotely! Always utilize the dry contact interlock terminals in the controller to provide the requisite signal and prevent remote door operation until the equipment is not in use.

NOTICE

  • DO NOT connect any dock equipment electrical wiring or ground connections until all welding has been completed. Failure to follow these instructions may damage the motor, hydraulics, wiring, and/or control panel.
  • Where indicated, all components must be connected to a SAFETY EARTH GROUND that conforms to the 1999 National Electrical Code Section 250-50 section (a) or section (c) for a grounding electrode system.

Mounting Control Panel

iDock-Link-2-Advanced-I-O-Controller- (13)

A Disconnect Panel (provided by others) C Distance, 48 in. (1219 mm)
B Control Panel D Dock Leveler
  1. Attach mounting feet to enclosure. See page 9 layout. Mount the control panel (B) so bottom of control panel-to-dock floor distance is 48 in. (1219 mm, C).
  2. Install electrical disconnect panel (A) if not already installed (provided by others). It is recommended to locate disconnect panel adjacent to control panel (B).
  3. Install and connect the control wiring as shown in installation drawings. See field wire entry schemas.

Note: When installing electrical controls in a temperature-controlled environment, the installer must determine an appropriate means to isolate/prevent thermal and vapor transfer through electrical conduit where conduit routing crosses temperature zones. Systems, LLC is not responsible for any damage due to moisture collecting inside the control panel caused by improper isolation/prevention of thermal and vapor transfer through the conduit. Refer to Tech Service Bulletin 19-053 for more information.

Install Outside Light Assembly – Optional

iDock-Link-2-Advanced-I-O-Controller- (12)

Note: Outside Lights are optional and not included with every iDock Link 2. Installation measurements shown are recommended based on typical dock conditions. Some installations may require alternate placement.

  1. Mount the Outside Light Assembly so center of outside light-to-drive distance is 96 in. (2438 mm).
  2. Connect the wiring for the Outside Light Assembly.
  3. Proceed with System Configuration.

Network Connection/ Configuration
After the iDock Control System has been installed and is powered on, follow these steps to connect it to the network.

Note: Green LED will blink until controller is connected.

  1. Open the front cover, by loosening the 4 Phillips screws, (A).
  2. With the controller open, locate the Reset Button on the control board. Press and hold the button (B) for 2 seconds.
  3.  On your mobile device, access Wi-Fi settings, and look for the “Link 2.0” Network.
    •  The format will be MyQ-xxx. The xxx is the last 3 digits of your Link 2 CP number.
      Note: If your device indicates that internet is not available, stay on this network until the configuration is complete. This network allows communication between your mobile device and the Link 2.
      iDock-Link-2-Advanced-I-O-Controller- (11)
  4. Open web browser and enter 192.168.1.1.
  5. Select Start to see the current internet connection method. See screen (C) below.
  6.  To change connection methods, select the desired connection and then click “Next” icon. See screen (D).iDock-Link-2-Advanced-I-O-Controller- (10)
  7. Select the SSID network the Link 2 will use.
  8. Enter the SSID password for the network. And then choose next. iDock-Link-2-Advanced-I-O-Controller- (9)
  9. Select Login.
  10.  When connected properly, the green “Network When connected properly, the green “Network LED” will be illuminated LED” will be illuminated solid green. If solid green. If the green the green LED is not illuminated, LED is not illuminated, check the Wi-Fi network check the Wi-Fi network and password are correct. and password are correct.
  11.  Choose next to begin configuration. Choose next to begin configuration. iDock-Link-2-Advanced-I-O-Controller- (8) iDock-Link-2-Advanced-I-O-Controller- (7)
  12.  Continue to page 15iDock-Link-2-Advanced-I-O-Controller- (2)
  13. Next, choose “Lamp Control”. This will set which sensor changes the communication lights. If the Link 2 is not controlling lights. Leave this value set to “None”. iDock-Link-2-Advanced-I-O-Controller- (2)
  14. De-bounce setting allows for adjustment in door sensor input timing. If you need to change this setting, please speak with Technical Services using the number on the front of this manual. iDock-Link-2-Advanced-I-O-Controller- (4)
  15. Choose “Save Changes.” The device will then attempt to connect to the network and apply the chosen settings iDock-Link-2-Advanced-I-O-Controller- (5)
  16. You will then be asked to verify the Network

LED StatusiDock-Link-2-Advanced-I-O-Controller- (6)

Solid green = Good signal strength & myQ connected. If Solid Green is chosen you will see the following message: iDock-Link-2-Advanced-I-O-Controller- (7)

If either of the options below are selected, you will receive the message below. You will need to reattempt the connecting procedure.

  • Blinking Green = Good signal strength & myQ NOT connected
  • Solid Red = No connection

iDock-Link-2-Advanced-I-O-Controller- (8)

OPERATION

DANGER

  • Stay clear of dock leveler and vehicle restraint when transport vehicle is entering or leaving dock area.
  • DO NOT move or use the dock leveler or restraint if anyone is under or in front of the dock leveler.
  • Keep hands and feet clear of pinch points. Avoid putting any part of your body near moving parts.

WARNING

  • Only trained personnel should operate the dock leveler and vehicle restraint.
  • DO NOT use a broken or damaged dock leveler or vehicle restraint. Make sure proper service and maintenance procedures have been performed on the equipment before operating.
  • Transport vehicle wheels must be chocked unless the vehicle restraint is used. Never remove the wheel chocks until loading/unloading is finished and transport vehicle driver has been given permission to leave.
  • Make sure platform lip rests on the transport vehicle bed with at least 4 in. (102 mm) of overlap.
  • Maintain a safe distance from side edges of leveler during the loading/unloading process.

Operation – Optional Sensors
The Link 2 can operate using the following inputs/sensors, provided via existing equipment or optional sensor kits:

  1. Door Sensor
  2. Vehicle Presence
  3. Restraint Engaged
  4. Leveler Stored
  5. Fluid Level
  6. Forklift Activity

Optional Kits Reference

Part Number Description
7155-0001 Fluid Level (Plastic Reservoir)
7155-0002 Fluid Level (Metal Reservoir)
0966-100001 Vehicle Presence
7155-0008 Forklift Activity
7155-0009 Leveler Stored
7155-0010 Door Open
7155-0011 Door Closed
0966-100002 Steel Rolling Door Sensor
0966-100013 Retroreflective Door Open

iDock-Link-2-Advanced-I-O-Controller- (6)

Normal Operation – Door Operated Lights
Door Closed = Bottom of door is < 13″ from grating. iDock-Link-2-Advanced-I-O-Controller- (5)

Door Open = Bottom of door is > 13″ from grating. iDock-Link-2-Advanced-I-O-Controller- (4)

Key Switch in Blocked Mode iDock-Link-2-Advanced-I-O-Controller- (3)

MAINTENANCE

Preventative Maintenance
Quarterly Maintenance should be performed on the system to ensure correct operation.

Quarterly Maintenance Checklist

  • At each dock position, operate the equipment through one complete cycle to verify correct operation. Check the door and its components for wear or damage that may affect sensor operation.
  • Rolling Door Sensor:
    1. Inspect the bracket for damage that may cause misalignment.
    2. Inspect the unit for dust or debris that may cause obstructions to sensor and target.
    3. Ensure conduit is secured to bracket and free of damage.
  • Sectional Door Sensors:
    1. Inspect the bracket for damage that may cause misalignment.
    2.  Inspect the unit for dust or debris that may cause obstructions to sensor and target.
    3.  Ensure conduit is secured to bracket and free of damage.
  • Link 2 Controller Diagnostics:
    1. Inspect the enclosure for damage or loose cover screws.
    2. Clean the exterior to ensure clear visibility of communication and status LEDs.

TROUBLESHOOTING

Multi-Colored Light Patterns
The iDock Link is equipped with a Multi-Colored LED Light that provides a simple and easily-understood visual reference for dock workers. It can display red, amber, and green colors, along with various flashing patterns to help diagnose situations.

iDock-Link-2-Advanced-I-O-Controller- (2)

Multi-Colored & Outside Light Sequence Charts

Normal Operation

Condition Lights
Inside Outside
Dock Door Closed (13″ or less from grating) RediDock-Link-2-Advanced-I-O-Controller- (9) GreeniDock-Link-2-Advanced-I-O-Controller- (10)
Dock Door Open GreeniDock-Link-2-Advanced-I-O-Controller- (10) RediDock-Link-2-Advanced-I-O-Controller- (9)

Block Mode Sequence (Key Switch)

Condition Lights
Inside Outside
Block Mode (Key Switch)* RediDock-Link-2-Advanced-I-O-Controller- (9) RediDock-Link-2-Advanced-I-O-Controller- (9)

Key Switch is used to override the door sensor. It manually changes the communication lights to Red / Red and makes the dock unavailable in myQ.

System Fault Sequence

Condition Lights
Inside Outside
Sensor Broken (Blocked Mode) RediDock-Link-2-Advanced-I-O-Controller- (9) RediDock-Link-2-Advanced-I-O-Controller- (9)

MISCELLANEOUSiDock-Link-2-Advanced-I-O-Controller- (1)

iDock Control System Information

  • Model: _______________________
  • Serial No: ____________________
  • Systems, LLC Job No: _________

Dock Leveler Information

  • Model: _______________________
  • Serial No: ____________________
  • Systems, LLC Job No: _________

Vehicle Restraint Information

  • Model: _______________________
  • Serial No: ____________________
  • Systems, LLC Job No: _________

Installation & Owner Details

  • Original Owner: ______________
  • Installer Name: ______________
  • Date of Installation: _________

STANDARD PRODUCT WARRANTY

  • SYSTEMS, LLC warrants that its products will be free from defects in design, materials and workmanship for a period of one (1) year from the date of shipment. All claims for breach of this warranty must be made within 30 days after the defect is or can with reasonable care, be detected. In no event shall any claim be made more than 30 days after this warranty has expired. In order to be entitled to the benefits of this warranty, the product must have been properly installed, maintained and operated in accordance with all manufacturer’s recommendations and/or specified design parameters and not otherwise have been subject to abuse, misuse, misapplication, acts of nature, overloading, unauthorized repair or modification, application in a corrosive environment or lack of maintenance. Periodic lubrication, adjustment and inspection in accordance with all manufacturers’ recommendations are the sole responsibility of the Owner/User.
  • In the event of a defect, as determined by SYSTEMS LLC, covered by this warranty, SYSTEMS LLC shall remedy such defect by repairing or replacing any defective equipment or parts, bearing the cost for the parts, labor and transportation. This shall be exclusive remedy for all claims whether based on contract, negligence or strict liability.

WARRANTY LIMITATIONS
THE ABOVE WARRANTIES ARE IN LIEU OF ANY OTHER WARRANTIES, WHETHER EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SYSTEMS LLC AND ITS SUBSIDIARIES SHALL NOT IN ANY EVENT BE LIABLE TO ANYONE, INCLUDING THIRD PARTIES, FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES OF ANY KIND INCLUDING BUT NOT LIMITED TO, BREACH OF WARRANTY, LOSS OF USE, LOSS OF PROFIT, INTERRUPTION OF BUSINESS OR LOSS OF GOODWILL.

Documents / Resources

PDF thumbnailLink 2 Advanced I/O Controller
User Manual · HBW73514, 73514, Link 2 Advanced I O Controller, Link 2, Advanced I O Controller, I O Controller, Controller

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.