IDEAL L2 Lever Push In Wire Connector

IDEAL L2 Lever Push In Wire Connector

Installation Instructions

Models L2, L3 & L5 

  • Do not exceed the rating of these connectors.
  • Turn OFF power before removing or installing connectors.
  • Wiring must comply with all applicable electrical regulations.
  • COPPER TO COPPER ONLY. Do not use on aluminium wire.
  • Incorrect use of these connectors can cause electrical fires, personal injury or death.
  • Use only one conductor per port.
  • Strip wires back 11-12mm.
  • For solid and rigid stranded wire, grip wire firmly and insert conductor into open port (lever does not need to be open).
  • For flexible stranded wire (>7 strands) lift lever and insert conductor into open port. Close lever.
  • Verify conductors are fully inserted to the back of the connector.
  • To remove a wire, lift lever and pull out wire.
  • Strip Length
    Installation Instructions
  • Insertion
    Installation Instructions
  • Removal
    Installation Instructions

Specifications

Specifications Model L2 2-Port Model L3 3-Port Model L5 5-Port
Rating

32 Amp / 450V / 85°

Depth

18.6 mm

Width 13.3 mm 18.9 mm 30.4 mm
Height

8.8 mm

Wire Combination Range Solid and Rigid Stranded

0.2mm2 – 4.0mm2

Flexible Wires

0.14mm2 – 4.0mm2