ideal logoOwner’s Manualideal BOILERS ESP1 Logic Combi

ESP1 Logic Combi

ideal BOILERS ESP1 Logic Combi - Symbol 1

LOGIC COMBI ESP1.

24 30 35
HIGH EFFICIENCY COMBINATION BOILERS
Optimised for new build compliance following the SAP 2009/2012 design procedure, the Logic Combi ESP1 achieves improved SAP efficiency scores and is particularly beneficial for new build properties.

KEY FEATURES

  • Easy to see pressure gauge
  • Large backlit display with user friendly controls
  • Low lift weight (starting from 28.9kg)
  • Low component count maximising reliability
  • OpenTherm ready
  • Complete range of Logic combination boilers for new build developers
  • Achieves improved SAP and DER performance for standard combination boiler usage
  • 75mm deep translucent condensate siphon
  • Fully modulating operation to low outputs
  • Automatic bypass

RELIABLE

  • Energy Saving Trust endorsed
  • NOx Class 5
  • Boiler frost protection
  • Built-in, easy to use filling loop
  • Simple diverter valve design
  • Two stage flame sensing for greater reliability
  • Latest generation Honeywell gas valve

EASY TO INSTALL

  • Compact cupboard fit
  • Fast fix flues
  • Wide range of additional flueing options
  • Preformed copper tails
  • Easy access to PRV and AAV
  • Pre-wired mains lead (2m)
  • Universal condensate connection
  • Stand off kit including piping available
  • Pre-piping kit
  • Compatible with a range of additional controls inc. weather compensation
  • LPG conversion kit available for 30 kW & 35 kW boilers

SAP REFERENCE NUMBERS
Logic Combi ESP1 24 017955
Logic Combi ESP1 30 017956
Logic Combi ESP1 35 017929

WEATHER COMPENSATION KIT
Part No. 216119

LPG CONVERSION KIT
Part No. (ESP1 30) 216423
Part No. (ESP1 35) 215752

ideal BOILERS ESP1 Logic Combi - Symbol 2Ideal Boilers
PO Box 103, National Avenue
Kingston upon Hull
East Yorkshire, HU5 4JN
T: 01482 492251
ideal@idealboilers.com
WWW.IDEALBOILERS.COM

CLEARANCES & DIMENSIONS.

DIMENSIONS IN MM

ideal BOILERS ESP1 Logic Combi - CLEARANCES & DIMENSIONS

Note: The minimum front clearance when built in to a cupboard is 5mm from the cupboard door but 450mm overall clearance with the cupboard door open is required for servicing. *Bottom clearance after installation can be reduced to 5mm. However, 100mm is required for servicing.

TECHNICAL SPECIFICATIONS.

BOILER MODEL 24 30 35
Weight (packaged) kg 33.7 33.8 33.9
Max installation weight kg 28.9 29.0 29.1
CH output (kW) min/max mean 70°C 4.8 – 24.2 6.1 – 24.2 7.1 – 24.2
CH output (kW) min/max mean 40°C 5.1 – 25.6 6.4 – 25.6 7.5 – 25.6
DHW output (kW) max 24.2 30.3 35.3
DHW flow rate l/min. 35°C rise 9.9 12.4 14.5
SEDBUK rating (2005) % 91.1 91.1 91.1
SEDBUK rating (2009/2012) % 89.6 89.6 89.6
NOx classification CLASS 5 CLASS 5 CLASS 5
Convert to LPG No Yes Yes
Max horizontal flue* 9m 8m 6m
Max vertical flue* 7.5m 7.5m 7.5m
Powered vertical flue† 22m 22m 22m
Condensing boiler Yes Yes Yes
Seasonal space heating efficiency class A A A
Rated heat output kW 24 24 24
Seasonal space heating energy efficiency ηs % 94 94 94
Sound power level, indoors LWA dB 48 46 44
Water heating energy efficiency class A A A

ideal BOILERS ESP1 Logic Combi - logo 2

Available Flue Extensions 0.5m, 1m and 2m. Multiple flue kits available.
* Each 90° elbow used is at the expense of 1000mm of straight flue run, and each 45° elbow is used at the expense of 600mm of straight flue run.
† Typical combined primary and secondary length. See installation instructions for more details.
Note: The Flue Deflector Kit is used at the expense of 1000mm of straight flue run.
211211 v19 21.02.18

ideal BOILERS ESP1 Logic Combi - logo 3USER GUIDE
LOGIC COMBI ESP1
24 30 35

When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers.
For the very latest copy of literature for specification and maintenance practices visit our website www.idealboilers.com where you can download the relevant information in PDF format.

April 2019
UIN 222353 A01

INTRODUCTION

The Logic Combi ESP1 range is a combination boiler providing both central heating and instantaneous domestic hot water. Featuring full sequence automatic ignition and fan assisted combustion.
Due to the high efficiency of the boiler, condensate is produced from the flue gases and this is drained to a suitable disposal point through a plastic waste pipe at the base of the boiler. A condensate ‘plume’ will also be visible at the flue terminal.

SAFETY
Current Gas Safety (Installation & Use) Regulations or rules in force.
In your own interest, and that of safety, it is the law that this boiler must be installed by a Gas Safe Registered Engineer, in accordance with the above regulations.
In IE, the installation must be carried out by a Registered Gas Installer (RGII) and installed in accordance with the current edition of I.S. 813 “Domestic Gas Installations”, the current Building Regulations and reference should be made to the current ETCI rules for electrical installation.
It is essential that the instructions in this booklet are strictly followed, for safe and economical operation of the boiler.

ELECTRICITY SUPPLY
This appliance must be earthed.
Supply: 230 V ~ 50 Hz. The fusing should be 3A.

IMPORTANT NOTES

  • This appliance must not be operated without the casing correctly fitted and forming an adequate seal.
  • If the boiler is installed in a compartment then the compartment MUST NOT be used for storage purposes.
  • If it is known or suspected that a fault exists on the boiler then it MUST NOT BE USED until the fault has been corrected by a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII).
  • Under NO circumstances should any of the sealed components on this appliance be used incorrectly or tampered with.
  • This appliance can be used by children 8 years and above. Also persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, provided they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

All Gas Safe Register installers carry a Gas Safe Register ID card, and have a registration number. Both should be recorded in the Benchmark Commissioning Checklist. You can check your installer by calling Gas Safe Register direct on 0800 4085500.

Ideal Boilers is a member of the Benchmark scheme and fully supports the aims of the programme. Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency.
THE BENCHMARK SERVICE INTERVAL RECORD MUST BE COMPLETED AFTER EACH SERVICE

ideal BOILERS ESP1 Logic Combi - logo 4

BOILER OPERATION

Legend
A. Domestic Hot Water Temperature Knob
B. Central Heating Temperature Knob
C. Mode Knob
D. Boiler Status Display
E. Burner ‘on’ Indicator
F. Installer Function Button
G. Restart Button
H. Central Heating Economy Setting
J. Pressure Gauge

ideal BOILERS ESP1 Logic Combi - BOILER OPERATION

TO START THE BOILER
If a programmer is fitted refer to separate instructions for the programmer before continuing.
Start the boiler as follows:

  1. Check that the electricity supply to boiler is off.
  2. Set the mode knob (C) to ‘BOILER OFF’.
  3. Set the Domestic Hot Water temperature knob (A) and Central Heating temperature knob (B) to ‘MAX’.
  4. Ensure that all hot water taps are turned off.
  5. Switch on electricity to the boiler and check that all external controls, e.g. programmer and room thermostat, are on.
  6. Set the mode knob (C) to ‘ideal BOILERS ESP1 Logic Combi - Symbol 3’ (winter).

The boiler will commence ignition sequence, supplying heat to the central heating, if required.
Note. In normal operation the boiler status display (D) will show codes:

ideal BOILERS ESP1 Logic Combi - Symbol 4 Standby – no demand for heat.
ideal BOILERS ESP1 Logic Combi - Symbol 5 Central Heating being supplied
ideal BOILERS ESP1 Logic Combi - Symbol 6 Domestic hot water being supplied
ideal BOILERS ESP1 Logic Combi - Symbol 7 Boiler frost protection
– boiler will fire if temperature is below 5ºC.

During normal operation the burner on indicator ‘ideal BOILERS ESP1 Logic Combi - Symbol 8’ will remain illuminated when the burner is lit.
Note: If the boiler fails to light after five attempts the fault code ideal BOILERS ESP1 Logic Combi - Symbol 9 will be displayed (refer to Fault Code page).

CONTROL OF WATER TEMPERATURE
Domestic Hot Water
The domestic hot water temperature is limited by the boiler controls to a maximum temperature of 65ºC, adjustable via the domestic hot water temperature knob (A).

Approximate temperatures for domestic hot water:

Knob Setting Hot Water Temperature (approx.)
Minimum 40ºC
Maximum 65ºC

Due to system variations and seasonal temperature fluctuations domestic hot water flow rates/temperature rise will vary, requiring adjustment at the tap: the lower the flow rate the higher the temperature, and vice versa.

Central Heating
The boiler controls the central heating radiator temperature to a maximum of 80ºC, adjustable via the central heating temperature knob (B).

Approximate temperatures for central heating:

Knob Setting Central Heating Radiator Temperature (approx.)
Minimum 30ºC
Maximum 80ºC

For economy setting ‘ideal BOILERS ESP1 Logic Combi - Symbol 10’ refer to Efficient Heating System Operation.

EFFICIENT HEATING SYSTEM OPERATION

The boiler is a high efficiency, condensing appliance which will automatically adjust its output to match the demand for heat. Therefore gas consumption is reduced as the heat demand is reduced.

The boiler condenses water from the flue gases when operating most efficiently. To operate your boiler efficiently (using less gas) turn the central heating temperature knob (B) to the ‘ideal BOILERS ESP1 Logic Combi - Symbol 10‘ position or lower. In winter periods it may be necessary to turn the knob towards the ‘MAX’ position to meet heating requirements. This will depend on the house and radiators used.
Reducing the room thermostat setting by 1ºC can reduce gas consumption by up to 10%.

WEATHER COMPENSATION
When the Weather Compensation option is fitted to the system then the central heating temperature knob (B) becomes a method of controlling room temperature. Turn the knob clockwise to increase room temperature and anti-clockwise to decrease room temperature. Once the desired setting has been achieved, leave the knob in this position and the system will automatically achieve the desired room temperature for all outside weather conditions.

BOILER FROST PROTECTION
The boiler is fitted with frost protection that operates in all modes, provided the power supply to the boiler is always turned on. If the water in the boiler falls below 5ºC, the frost protection will activate and run the boiler to avoid freezing. The process does not guarantee that all other parts of the system will be protected.

If a system frost thermostat has been installed, the boiler must be set in winter mode, ‘ideal BOILERS ESP1 Logic Combi - Symbol 3’, for the system frost protection to run.

If no system frost protection is provided and frost is likely during a short absence from home it is recommended to leave the system heating controls or built in programmer (if fitted) switched on and run at a reduced temperature setting. For longer periods, the entire system should be drained.

BOILER RESTART
To restart the boiler, when directed in the listed fault codes (see section 8) press the restart button (G). The boiler will repeat its ignition sequence. If the boiler still fails to start consult a Gas Safe Registered Engineer or an IE Registered Gas Installer (RGII).

MAINS POWER OFF
To remove all power to the boiler the mains power switch must be turned off.

SYSTEM WATER PRESSURE

The system pressure gauge indicates the central heating system pressure. If the pressure is seen to fall below the original installation pressure of 1-2 bar over a period of time and continue to fall then a water leak may be indicated. In this event re-pressurise the system as shown below. If unable to do so or if the pressure continues to drop a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII) should be consulted.

ideal BOILERS ESP1 Logic Combi - SYSTEM WATER PRESSURE

THE BOILER WILL NOT OPERATE IF THE PRESSURE HAS REDUCED TO LESS THAN 0.3 BAR UNDER THIS CONDITION.

To Top up the system:

  1. Ensure both A & B handles (blue) are in closed position (as shown below)
  2. Remove the plug and cap and retain.
  3. Connect the filling loop to the Domestic Hot Water (DHW) inlet and tighten. Also ensure that the other end of filling loop is hand tight.ideal BOILERS ESP1 Logic Combi - Filling Positionideal BOILERS ESP1 Logic Combi - Starting Position
  4. Turn the Domestic Hot Water (DHW) Inlet A blue handle to the horizontal position.
  5. Ensuring no leaks are seen, gradually turn the filling loop handle (blue) B to the horizontal position.
  6. Wait for the pressure gauge to reach 1 to 1.5 bar.
  7. Once pressure is reached turn valves A & B back to the closed position.
  8. Disconnect the filling loop, replace cap and plug. Note there can be some water spillage at this point.

CONDENSATE DRAIN

This appliance is fitted with a siphonic condensate trap system that reduces the risk of the appliance condensate from freezing.
However should the condensate pipe to this appliance freeze, please follow these instructions:
a. If you do not feel competent to carry out the defrosting instructions below please call your local Gas Safe Registered installer for assistance.
b. If you do feel competent to carry out the following instructions please do so with care when handling hot utensils. Do not attempt to thaw pipework above ground level.
If this appliance develops a blockage in its condensate pipe, its condensate will build up to a point where it will make a gurgling noise prior to locking out an “ideal BOILERS ESP1 Logic Combi - Symbol 9” fault code. If the appliance is restarted it will make a gurgling noise prior to it locking out on a failed ignition “ideal BOILERS ESP1 Logic Combi - Symbol 9” code.

To unblock a frozen condensate pipe;

  1. Follow the routing of the plastic pipe from its exit point on the appliance, through its route to its termination point.
    Locate the frozen blockage. It is likely that the pipe is frozen at the most exposed point external to the building or where there is some obstruction to flow. This could be at the open end of the pipe, at a bend or elbow, or where there is a dip in the pipe in which condensate can collect. The location of the blockage should be identified as closely as possible before taking further action.
  2. Apply a hot water bottle, microwaveable heat pack or a warm damp cloth to the frozen blockage area. Several applications may have to be made before it fully defrosts. Warm water can also be poured onto the pipe from a watering can or similar.
    DO NOT use boiling water.
  3. Caution when using warm water as this may freeze and cause other localised hazards.
  4. Once the blockage is removed and the condensate can flow freely, restart the appliance. (Refer to “To Light the boiler”)
  5. If the appliance fails to ignite, call your Gas Safe Registered engineer.

Preventative solutions
During cold weather, set the central heating temperature knob (B) to maximum (must return to original setting once cold spell is over).
Place the heating on continuous and turn the room thermostat down to 15ºC overnight or when unoccupied. (Return to normal after cold spell).

GENERAL INFORMATION

BOILER PUMP
The boiler pump will operate briefly as a self-check once every 24 hours, regardless of system demand.

MINIMUM CLEARANCES
Clearance of 165mm above, 100mm below, 2.5mm at the sides and 450mm at the front of the boiler casing must be allowed for servicing.

Bottom Clearance
Bottom clearance after installation can be reduced to 5mm.
This must be obtained with an easily removable panel, to enable the system pressure gauge to be visible and to provide the 100mm clearance required for servicing.

EXPANSION
NOTE. If a water meter is fitted into the incoming water mains there may be a requirement for a domestic hot water expansion vessel Kit. Contact a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII).

ESCAPE OF GAS
Should a gas leak or fault be suspected contact the National Gas Emergency Service without delay. Telephone 0800 111 999.
Ensure that;
– All naked flames are extinguished
– Do not operate electrical switches
– Open all windows and doors

CLEANING
For normal cleaning simply dust with a dry cloth. To remove stubborn marks and stains, wipe with a damp cloth and finish off with a dry cloth. DO NOT use abrasive cleaning materials.

MAINTENANCE
The appliance should be serviced at least once a year by a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII).

POINTS FOR THE BOILER USER

Note. In line with our current warranty policy we would ask that you check through the following guide to identify any problems external to the boiler prior to requesting a service engineer’s visit. Should the problem be found to be other than with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is not gained by the engineer.

TROUBLESHOOTING

ideal BOILERS ESP1 Logic Combi - TROUBLESHOOTING

NORMAL OPERATION DISPLAY CODES

DISPLAY CODE ON BOILER DESCRIPTION
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 1 The boiler is in standby operation awaiting either a central heating call or hot water demand.
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 2 The boiler has a call for central heating but the appliance has reached the desired temperature set on the boiler.
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 3 The boiler has a call for hot water but the appliance has reached the desired temperature set on
the boiler.
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 4 The boiler is operating in central heating mode.
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 5 The boiler is operating in domestic hot water mode.
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 6 The boiler is operating in frost protection.
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 7 The boiler mode knob (C) is in the off position, rotate fully clockwise for hot water and central
heating operation.

FOR ANY QUERIES PLEASE RING THE IDEAL CONSUMER HELPLINE : 01482 498660

NOTE. BOILER RESTART PROCEDURE –
To restart the boiler press the RESTART button. The boiler will repeat the ignition sequence if a heat demand is present.

FAULT CODES

DISPLAY CODE ON BOILER DESCRIPTION ACTION
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 8 Low Water Pressure Check system water pressure is between 1 & 1.5 bar on the system pressure gauge. To re-pressurise the system see Section 3. If the boiler still fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 9 Flame Loss 1. Check other gas appliances in the house are working to confirm a supply is present in the property.
2. If other appliances do not work or there are no other appliances, check the gas supply is on at the meter and/or pre payment meter has credit. If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 10 Fan Fault Restart the appliance – if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 11 Flow Thermistor Restart the appliance – if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 12 Return Thermistor Restart the appliance – if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 13 Outside Sensor Failure Restart the appliance – if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 14 Low Mains Voltage Contact a qualified electrician or your electricity provider.
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 15 Unconfigured PCB Unconfigured PCB. Please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 16 Flow Temperature Overheat or No Water Flow Check system water pressure is between 1 & 1.5bar on the system pressure gauge.
To re-pressurise the system see Section 3. If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 17 Ignition Lockout 1. Check condensate Pipe for blockages (refer to Section 4)
2. Check other gas appliances in the house are working to confirm a supply is present in the property.
3. If other appliances do not work or there are no other appliances, check the gas supply is on at the meter and/or pre payment meter has credit. If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 18 False Flame Lockout Restart the appliance – if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 19 5 Boiler Resets in 15 minutes 1. Turn electrical supply to boiler off and on.
2. If the boiler fails to operate please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 20 Negative Differential Flow/Return Thermistor If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 21 Flow/Return Differential > 50°C If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).
ideal BOILERS ESP1 Logic Combi - DISPLAY CODE ON BOILER 22 Diverter Valve in mid-position for service Rotate all knobs fully clockwise, turn boiler power off and on then press restart

www.idealboilers.comideal BOILERS ESP1 Logic Combi - Symbol 11

USER GUIDE
Welcome to your new Ideal Halo control. This thermostat will help you to control both your heating temperature and the times that your heating is on.

Halo is a battery powered, wireless control that uses a protocol called Zigbee to communicate with the Smart Interface that plugs into the boiler.
This user guide is applicable to both the Halo Combi RF and Halo Combi Wi-Fi control.
Halo Combi RF is a non-connected control (control is via the Halo Combi unit only).

Halo Combi Wi-Fi is a wireless heating control that is connected to the internet. You can download the Halo app on Google Play or the Apple app store. You will not have to pay to use the app.
For more information on the features in your Halo app visit the Help section of the app or www.idealboilers.com.

ideal BOILERS ESP1 Logic Combi - Parts

If you have purchased a Halo Combi RF (non-connected control) you can upgrade this to an internet heating control by downloading the Halo app and following the steps in the app to connect your Halo control. You will be required to pay a connection fee to upgrade to app controlled heating.

MAIN FEATURES
MODE SELECTION
You can choose to run your Halo in Auto, Manual or Off mode.
Auto: runs your heating to pre-set scheduled times and temperatures.
Manual: you control the temperature by manually turning the dial, there are no set schedules.
Off: your heating will be set to a low temperature (default 5°C) for frost protection.
Move between Auto, Manual and Off modes using the right hand side button, scroll down the menu using the dial and push to select.

ideal BOILERS ESP1 Logic Combi - MODE SELECTION

TOP TIP
Your Halo is designed to provide the perfect balance of comfort and efficiency. It has a feature called Enhanced Load Compensation which balances the temperature in your radiators to maintain the target room temperature with optimum efficiency. As a result you might notice that when the temperature in your home reaches the target your radiators are not hot to touch. By controlling the temperature in your radiators your system is working in the most efficient way for you.

MAIN FEATURES
PLUS HOURS
If you are running a schedule with pre-set times (Auto mode) and you want to maintain the current temperature of your heating instead of moving to the next setting simply press the dial.
A pop up menu will appear for you to select how long you would like to extend the temperature for, turn and push the dial to make your selection.

ideal BOILERS ESP1 Logic Combi - PLUS HOURS

TOP TIP
You could use this feature if you want to keep your heating on for longer than is scheduled.
Maybe you’re not going to work today and you want your heating to stay on all morning.

ideal BOILERS ESP1 Logic Combi - TOP TIP

MAIN FEATURES
OVERRIDE
If you are running a schedule with pre-set times (Auto mode) and you want to adjust the temperature of your heating temporarily, simply turn the dial to your desired temperature.
The new temperature will be active until the next scheduled change shown under the target temperature.
The home screen will now display the override icon above the current temperature.

ideal BOILERS ESP1 Logic Combi - OVERRIDE

TOP TIP
You could use this feature if you want to boost your heating to a higher temperature for a period of time. Maybe you’re feeling chilly or it’s the weekend and you’re staying up later than when your heating is scheduled.

MAIN FEATURES
SCHEDULES
Your Halo will come with a pre-set schedule:
6:00 – 8:00 21°C
8:00 – 16:00 OFF
16:00 – 22:00 21°C
22:00 – 6:00 OFF
You can alter this schedule by entering the “timed heating schedule” section in the main menu.

ideal BOILERS ESP1 Logic Combi - SCHEDULES

Turn the dial to move between the different days and view the schedule that is set. To edit a day, push the dial or right hand button when the day is highlighted in light blue.

TOP TIP
If you want to change more than one day you can use the copy day feature to copy the schedule from one day to other days.

ideal BOILERS ESP1 Logic Combi - TOP TIP 2

Push the dial to edit a heating time or temperature when it is highlighted in light blue. You can also add an additional heating period by scrolling and pushing on the “Add new heating event” bar. You can have up to 6 heating events per day in your schedule.

TOP TIP
Schedules help to balance comfort and energy efficiency, so you are heating your home to suit your lifestyle.
Don’t forget you could set your weekend schedules differently to during the week if your routine changes.

ideal BOILERS ESP1 Logic Combi - TOP TIP 3

Alter the start and end times of the heating period and the temperature by scrolling and then pushing the dial to edit. Then use the dial to alter the time or temperature and push to confirm. Push the dial or the right hand button to save your changes.

HALO SMART INTERFACE

The Halo Smart Interface will be installed in the aperture in the front of your Ideal boiler. It will wirelessly communicate with your Halo control and, in the case of an internet connected Halo, your home Wi-Fi. In normal circumstances you will not have to interact with the Halo Smart Interface, however the LED indications can be useful in diagnosing any technical issues that may arise.
The Halo Smart Interface has a Failsafe/Override feature which can be used to switch your boiler on if wireless communication between the Halo and Smart Interface is lost.

ideal BOILERS ESP1 Logic Combi - HALO SMART INTERFACE

ADDITIONAL FEATURES

Holiday Mode To temporarily turn your heating off whilst you are on holiday, select the holiday function in the menu and use the dial and buttons to set the number of days.
Support Page Provides information for your installer or technical expert about your Halo such as software version and wireless signal strength.
Child Lock To lock the control to avoid it being altered press and hold the left and right hand buttons at the same time until the icon appears. To remove child lock press and hold the left and right hand buttons again.
Date & Time If the date and time seen across the top of the screen is incorrect you can alter this in the date and time section of the menu.
Advanced Settings The advanced settings section of the menu allows your installer or a technical expert to make adjustments and find information about your Halo.
Fault Notification If there is a fault then the fault symbol  will show on the home screen of your Halo. Press the left hand button to access further information about the fault.
Name Explanation
ideal BOILERS ESP1 Logic Combi - Flame Flame Indicates your heating is on
ideal BOILERS ESP1 Logic Combi - Fault Fault Indicates there is a fault with the boiler
ideal BOILERS ESP1 Logic Combi - Child lock Child lock Childlock is set so the Halo cannot be altered
ideal BOILERS ESP1 Logic Combi - Override 2 Override Override or plus hours function is active
ideal BOILERS ESP1 Logic Combi - Optimised start Optimised start Optimised start is active
ideal BOILERS ESP1 Logic Combi - Delayed start Delayed start Delayed start is active
ideal BOILERS ESP1 Logic Combi - Optimised Stop Optimised stop Optimised stop is active
ideal BOILERS ESP1 Logic Combi - Frost Frost protection Frost protection is active
ideal BOILERS ESP1 Logic Combi - Service due Service due Service due in:
– 60 days (grey)
– 30 days (amber)
– 0 days (red)
Name Explanation
Hi
room temp
Hi Room temperature is above 40°C
Lo
room temp
Lo Room temperature is below 0°C
30.0
target temp
Target Temp Temperature you want your heating to reach
23.2
current temp
Current Temp Room temperature in the location of your Halo
22:33 Time Current time
Sat, 17 Nov Date Current date
ideal BOILERS ESP1 Logic Combi - Battery Battery Battery status indication
ideal BOILERS ESP1 Logic Combi - Zigbee Zigbee Indicates that the Halo is communicating with the Smart Interface
ideal BOILERS ESP1 Logic Combi - Cloud Cloud* Indicates that the Halo is communicating with internet and can be controlled with the Halo app via your smart phone
*Halo Combi Wi-Fi only

CHANGING THE BATTERIES IN YOUR HALO CONTROL

A red, empty battery symbol means that your Halo batteries need to be replaced.
ideal BOILERS ESP1 Logic Combi - CHANGING THE BATTERIES 2

Whether you have a desk or wall mounted unit you will see the battery symbol on the base of the unit. There are also two finger grabs top and bottom as shown below. Use the finger grabs to gently pull the Halo away from the rear housing.

ideal BOILERS ESP1 Logic Combi - CHANGING THE BATTERIES 1

Remove all the old batteries and replace with 4 new AA Alkaline batteries. Check you have the correct battery orientation then position the Halo back onto the rear housing and gently push into place until you feel a positive click.

ideal BOILERS ESP1 Logic Combi - CHANGING THE BATTERIES 3

The Halo will go through a short synchronisation process while it reconnects with your Halo Smart Interface. The Halo will then return to the home screen.

ideal BOILERS ESP1 Logic Combi - CHANGING THE BATTERIES 4

TROUBLE SHOOTING

1. HALO NOT COMMUNICATING WITH HALO SMART INTERFACE
If the below message shows on the Halo screen then it is not communicating with the Halo Smart Interface.

ideal BOILERS ESP1 Logic Combi - SMART INTERFACE

Please follow the on screen recommendations, additionally for further help you can also visit www.idealboilers.com
Please note even without a signal between the Halo and the Halo Smart Interface the heating will continue to operate in Failsafe mode. In Failsafe mode the schedule will still operate however the output temperature of the boiler will be reduced.
You can also manually switch your boiler On and Off by using Override button on the Smart Interface. When the Override is pressed it will disable failsafe mode and allow full manual control of the boiler until the connection is restored. When communication is restored both Failsafe and Override modes are disabled.

2. BOILER AND CONTROL FAULTS
If the fault icon appears in the home screen it means there is a control or boiler fault. Press the left hand key to view the fault and recommendations.

ideal BOILERS ESP1 Logic Combi - BOILER AND CONTROL FAULTS

3. LOST PAIRING BETWEEN HALO AND HALO SMART INTERFACE
In the unlikely event that the Halo loses pairing you will see the following screen.

ideal BOILERS ESP1 Logic Combi - SMART INTERFACE 2

To re-pair go to section E in the Halo Combi installation instructions. You can also find a copy of the installation guide at www.idealboilers.com

WARRANTY

Your Ideal Halo comes complete with a 2 year Ideal Guarantee, subject to the following terms and conditions.
During the period of the guarantee we will replace free of charge, where it suffers a mechanical or an electrical breakdown as a result of defective workmanship or materials, subject to the following conditions and exclusions;

  1. The guarantee will commence from the date of installation. Without proof of purchase the guarantee will commence from the date of manufacture (via serial number).
  2. The Installation needs to be registered within 30 days of installation, it can be registered online by visiting www.idealboilers.com.
  3. If the control suffers a mechanical or an electrical breakdown we should be contacted on one of the following numbers:

Northern Ireland:
T: 02890 331444

Elsewhere in the UK:
T: 01482 498660

Our normal working times, excluding Bank Holidays, are:
8am – 6pm Monday to Friday
8am – 4pm Saturday
8am – 12 noon Sunday
4. The guarantee does not apply:

a. To any defect, damage or breakdown caused by deliberate action, accident, misuse or third party interference including modification or failed batteries.
b. To any defect, damage or breakdown caused by the design, installation and maintenance of the central heating system.
d. To any other costs or expenses caused by or arising as a result of the breakdown of the controls.
e. To any defect resulting from the incorrect installation of the controls. To any costs incurred during delays in fixing reported faults.

Our Ideal Guarantee is offered in addition to the rights provided to a consumer by law. Details of these rights can be obtained from a Trading Standards Authority or a Citizens Advice Bureau.

Guarantor
Ideal Boilers Ltd, National Avenue, Hull, HU5 4JN.

Consumer Helpline
T: 01482 498660

Installer phone number:

This product contains free and open source software. For more information about that software, the licences and notices applicable to it, and (where applicable) how to obtain a copy of the source code, please see the licence document, a copy of which can be downloaded from: https://idealboilers.com/open-source

ideal BOILERS ESP1 Logic Combi - logo 3

Hereby, Ideal Boilers Ltd declares that this device (model 222140 & 222142) is in compliance with: Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address: www.idealboilers.com

For more information and FAQs visit the Ideal Boilers website www.idealboilers.com

ideal BOILERS ESP1 Logic Combi - Symbol 12UIN: 224237 A02
RF frequency: 2405 –2480MHz
Max. RF output power: 10dBm
Ideal Boilers Ltd
National Avenue
Hull, HU5 4JN
T: 01482 498660
E: enquiries@idealboilers.com