1. Informasi Keselamatan

This manual transfer switch is designed to safely connect a generator to your home's electrical system. Improper installation or use can result in serious injury or death. Always consult a qualified electrician for installation and ensure all local electrical codes are followed.

  • Ensure the main utility power is disconnected before working on the electrical system.
  • Never operate the generator indoors or in enclosed spaces to prevent carbon monoxide poisoning.
  • Jangan melebihi batas air maksimumtage atau amperage ratings of the transfer switch or individual circuits.
  • The double-throw switch design prevents back-feeding power to the utility grid, ensuring safety for utility workers.

2. Produk Lebihview

The VEVOR 30-Amp 10-Circuit Manual Generator Transfer Switch Kit provides a reliable solution for switching between utility power and generator backup during outages. It is compatible with generators up to 7500W.

Fitur Utama:

  • 30A, 10-Circuit Capacity: Manages up to 30 amps across 10 circuits, allowing selective power transfer.
  • Desain Pra-Kabel: Simplifies installation with clearly labeled wiring.
  • Konstruksi Tahan Lama: Features an easy-to-operate double-throw switch and U.S. standard mini circuit breakers for overcurrent protection.
  • Mechanical Watt Meter: Provides stable and accurate monitoring of generator load.
  • NEMA 3R Weatherproof Enclosure: Suitable for both indoor and outdoor use, protecting internal wiring from harsh conditions.
  • Power Input Box Included: Equipped with an L14-30 plug and protective lid for stable power input.
VEVOR 30-Amp 10-Circuit Manual Generator Transfer Switch Kit installed on a wall, connected to a generator via an inlet box.

Figure 1: VEVOR 30-Amp 10-Circuit Manual Generator Transfer Switch Kit, highlighting its 30A current, 7500W generator compatibility, and 10 circuits. An external power inlet box is shown connected to a generator.

Close-up of the VEVOR transfer switch's internal components, showing double-throw switches and mechanical wattmeters.

Gambar 2: Rinci view of the transfer switch's internal panel, featuring double-throw switches for generator/line selection and mechanical wattmeters for load monitoring. This illustrates the durable construction and reliable monitoring capabilities.

VEVOR transfer switch in a NEMA 3R weatherproof enclosure, shown in an outdoor setting with rain, snow, sun, and dust icons.

Figure 3: The NEMA 3R weatherproof enclosure of the VEVOR transfer switch, designed for both indoor and outdoor use, offering protection against rain, snow, intense sunlight, and dust storms.

3. Pengaturan dan Instalasi

The VEVOR transfer switch kit comes pre-wired to simplify installation. However, professional installation by a licensed electrician is highly recommended to ensure compliance with all electrical codes and safety standards.

Komponen untuk Instalasi:

  • Manual Transfer Switch (pre-wired)
  • NEMA L14-30P Power Inlet Box
  • Saluran PVC
  • Panduan Pengguna
Close-up of the pre-wired internal components of the VEVOR transfer switch, showing labeled wires and standard wiring for secure connections.

Figure 4: The pre-wired design of the transfer switch, featuring clearly labeled wires and robust standard wiring for secure and durable connections, simplifying the setup process.

The VEVOR power inlet box with an L14-30 plug and a protective lid.

Figure 5: The included power input box, equipped with an L14-30 plug and a protective lid, designed to provide a stable and reliable power input connection from your generator.

Pengkabelanview:

The transfer switch connects to your main electrical panel and an external power inlet box. The power inlet box receives power from your generator. The pre-wired nature of the VEVOR switch means the internal connections are largely complete, requiring connection to your home's circuits and the inlet box.

Video 1: This video demonstrates the wiring process for the VEVOR Manual Transfer Switch, including connecting the input wires from the power inlet box, and connecting the output wires to the household distribution box. It also shows how to secure neutral and ground connections and switch between LINE and GEN modes.

Penting: The power inlet box should be located a minimum of 10 feet away from any building openings (windows, doors, vents) to prevent generator exhaust from entering your home.

The transfer switch allows you to select specific circuits to be powered by the generator. The internal wiring is clearly labeled (A-J) to correspond with your chosen household circuits.

Intern view of the VEVOR transfer switch with circuit labels and switches.

Gambar 6: Internal view of the transfer switch, showing the individual circuit switches (GEN/LINE) and the wattmeters. The labels A-J correspond to the circuits that can be connected.

4. Petunjuk Pengoperasian

Follow these steps to safely transfer power from utility to generator and back:

When Utility Power Goes Out (Switch to Generator Power):

  1. Leave all switches on the VEVOR Transfer Switch in the LINE position. It is not necessary to shut off the MAIN breaker in your breaker panel.
  2. Move your generator to its operating location. Ensure the generator exhaust does not enter your home.
  3. Plug the power cord into the generator and the Inlet Box.
  4. Nyalakan generator Anda dan biarkan selama 10 menit untuk memanas. CATATAN: Jangan pernah menghidupkan generator Anda dengan sakelar apa pun dalam posisi GEN.
  5. Alihkan rangkaian yang diinginkan ke posisi GEN. Perhatikan arus yang mengalir.tage indicated on the watt meters. Attempt to balance the meters to within 1000W of each other. Do not exceed the maximum wattagtercetak pada meteran.

When Utility Power is Restored (Switch Back to Utility Power):

  1. Move any switches that are in the GEN position to the LINE position.
  2. Matikan genset. CATATAN: Jangan pernah mematikan generator Anda saat sakelar apa pun berada di posisi GEN.
  3. Cabut dan simpan kabel daya.

Refer to the 'Operation Guide' label located on the inside of the transfer switch door for quick reference.

5. Pemeliharaan

Perawatan rutin memastikan umur pakai yang panjang dan pengoperasian yang aman dari sakelar transfer Anda.

  • Periksa secara berkala semua sambungan kabel untuk memastikan kekencangannya dan tanda-tanda keausan atau korosi.
  • Keep the enclosure clean and free from dust, debris, and moisture.
  • Ensure the NEMA 3R enclosure seals are intact to maintain weather resistance.
  • Test the transfer switch operation periodically (e.g., every 3-6 months) by simulating a power outage with your generator.

6. Penyelesaian masalah

If you encounter issues with your VEVOR Manual Generator Transfer Switch, consider the following:

  • No Power to Circuits:
    • Check if the generator is running and producing power.
    • Ensure the power cord is securely connected to both the generator and the inlet box.
    • Verify that the circuit selector switches on the transfer panel are in the 'GEN' position.
    • Check the mini circuit breakers on the transfer switch for any tripped breakers.
  • Watt Meters Not Registering:
    • Confirm that circuits are actively drawing power from the generator.
    • Ensure the generator is providing sufficient voltage.
  • Suara atau Bau yang Tidak Biasa: Immediately shut down the generator and disconnect all power. Contact a qualified electrician for inspection.

7. Spesifikasi

Fitur Spesifikasi
Nomor Model Barang SP-ZH352510(30A-10)
Saat ini 30A
Jil.tage AC 120 / 240V
Jumlah Sirkuit 10 (2 x 2-Pole + 6 x Single-Pole)
Kompatibilitas Pembangkit 7500W
Bahan Penutup Baja Canai Dingin
Berat Bersih 19.64 pon / 8.91 kg
Dimensi Produk 14.65 x 9.76 x 4.72 inci (372 x 248 x 120 mm)
Diagram showing the dimensions and key specifications of the VEVOR transfer switch and power inlet box.

Figure 7: Visual representation of the product dimensions and a summary of key specifications for the VEVOR transfer switch kit.

8. Garansi dan Dukungan

VEVOR products are designed for durability and performance. For technical support or warranty information, please refer to the E-Warranty Certificate included with your product or visit the official VEVOR weblokasi.

Informasi Kontak:

Dokumen Terkait - SP-ZH352510

Praview Sakelar Transfer Manual VEVOR: Seri SP-ZH352510 - Output DayatagSolusi e
Panduan lengkap untuk Sakelar Transfer Manual VEVOR (Model SP-ZH352510(30A-6), SP-ZH352510(30A-10), SP-ZH352510(50A-10)). Pelajari tentang instalasi, spesifikasi, dan manajemen daya generator yang aman selama penggunaan.tagyaitu.
Praview VEVOR Manual Transfer Switch Installation and Operation Guide
Comprehensive guide for VEVOR Manual Transfer Switches (Models SP-ZH352510 series), covering installation, wiring, operation, and troubleshooting for safe and reliable generator power integration.
Praview Set Kabel Ekstensi dan Kotak Input Daya VEVOR: Model LA047A/LA048A+LSTK07
Set Kabel Ekstensi dan Kotak Input Daya VEVOR ini (Model LA047A, LA048A, LSTK07) menyediakan koneksi yang aman dan andal untuk generator. Termasuk petunjuk pemasangan, parameter produk, dan panduan penggunaan untuk pengaturan dan pengoperasian yang optimal.
Praview Panduan Instalasi Set Kabel Ekstensi & Kotak Input Daya VEVOR - LA047A/LA048A+LSTK07
Panduan lengkap untuk Set Kabel Ekstensi & Kotak Input Daya VEVOR (Model LA047A/LA048A+LSTK07). Termasuk petunjuk pemasangan, parameter produk, dan metode aplikasi untuk koneksi daya yang aman dan andal.
Praview VEVOR Extension Cable & Power Inlet Box Set Installation and User Manual
Comprehensive guide for VEVOR's Extension Cable and Power Inlet Box Set (Model RV50H/SS2-50R+LSTK06), including product parameters, installation instructions, wiring details, and application methods for safe and reliable power connections.
Praview VEVOR Extension Cable & Power Inlet Box Set Installation and User Manual
Comprehensive guide for the VEVOR Extension Cable & Power Inlet Box Set (Model: RV50H/SS2-50R+LSTK06), detailing installation instructions, product parameters, and usage guidelines for safe and reliable power connections.