ICP DAS-LOGOICP DAS U-7524M CR UA I/O Series 5 Channels DO and 2 Port Ethernet Switch

ICP-DAS-U-7524M-CR-UA-I-O-Series-5-Channels-DO-and-2-Port-Ethernet-Switch -PRODUCT

Packing List

UA I/O package includes this document and the following items:

ICP-DAS-U-7524M-CR-UA-I-O-Series-5-Channels-DO-and-2-Port-Ethernet-Switch -FIG-1

Technical Resources
How to search for drivers, manuals and spec information on ICP DAS website

ICP-DAS-U-7524M-CR-UA-I-O-Series-5-Channels-DO-and-2-Port-Ethernet-Switch -FIG-3

Preparations for Devices

  1. PC/NB: Can connect to the network and set the network
  2. Ethernet Switch/Hub (Ex: NS-205A or PoE Switch NSM-208SE)
  3. Power Supply: +12 ~ +48 VDC (Ex: MDR-60-24)

Hardware Connection

Connect the UA I/O Module with the RJ-45 Ethernet port to an Ethernet switch/hub (Fig.2 for PoE Switch) and PC. You can also directly link the U-75xx to PC with an Ethernet cable. After power is connected, please【wait 1 minute】for U-75xx  start-up procedure. When the “RUN” light starts flashing, it represents the boot is complete.

ICP-DAS-U-7524M-CR-UA-I-O-Series-5-Channels-DO-and-2-Port-Ethernet-Switch -FIG-4

Network Connection

Factory Default Settings of U-75xx
 

 

Network

IP 192.168.255.1 Assign U-75xx a new IP setting according to your case.
Mask 255.255.0.0
Gateway 192.168.1.1
Web UI Account Username root After login, change the username/ password at once.
Password root
  • Change the PC’s IP setting as following. (Write down the PC original network settings before modify.) EX:
IP 192.168.255.10
Subnet mask 255.255.0.0
Default Gateway 192.168.1.1
  • Make sure the PC and U-75xx is connecting through Ethernet. And then open a PC side browser (Ex: Chrome, IE…). Type http://192.168.255.1 in the URL address. Use default Web UI username/password root/root to login.ICP-DAS-U-7524M-CR-UA-I-O-Series-5-Channels-DO-and-2-Port-Ethernet-Switch -FIG-5
  • Change the Username/password in 【Account Setting】of 【System Setting】, or user cannot use any other functionICP-DAS-U-7524M-CR-UA-I-O-Series-5-Channels-DO-and-2-Port-Ethernet-Switch -FIG-6
  • Click【System Setting】【Network Setting】>【Network Setting(LAN)】to change the IP settings by user networkICP-DAS-U-7524M-CR-UA-I-O-Series-5-Channels-DO-and-2-Port-Ethernet-Switch -FIG-7
  • Save the IP settings, restore the PC original IP settings, and then type the new IP/Username/Password in the browser to login the Web UI of U-75xx to configure user’s UA project

AI/AO Jumper Setting

To change the Selection Jumpers for Analog channels:

U-7528M
Channel
Jumper
Channel V/Iout6+ V/Iout7+
Jumper J1 J2

Remove the top case and upper board of the module, the selection jumpers are next to the connector.ICP-DAS-U-7524M-CR-UA-I-O-Series-5-Channels-DO-and-2-Port-Ethernet-Switch -FIG-8

U-7502M
Channel Vin1± Vin0±
Jumper J2 J1
Channel Vin2±
Jumper J3
U-7528M
Channel
Jumper
Channel V/Iout6+ V/Iout7+
Jumper J1 J2
U-7517M-10
Channel Vin8± Vin7± Vin6± Vin5± Vin4± Vin3± Vin2± Vin1± Vin0±
Jumper J9 J8 J7 J6 J5 J4 J3 J2 J1
Channel Vin9±
Jumper J10

Jumper Location Figure

ICP-DAS-U-7524M-CR-UA-I-O-Series-5-Channels-DO-and-2-Port-Ethernet-Switch -FIG-9

U-7504M
Channel Vin3 Vin2 Vin1 Vin0 Vout3 Vout2 Vout1 Vout0
Jumper J4 J3 J2 J1 J8 J7 J6 J5
U-7524M
Channel Vout3+ Vout2+ Vout1+ Vout0+
Jumper J4 J3 J2 J1
U-7526M
Channel Vout1 Vout0 Vin5 Vin4 Vin3 Vin2 Vin1 Vin0
Jumper J8 J7 J6 J5 J4 J3 J2 J1
U-7517M
Channel Vin7± Vin6± Vin5± Vin4± Vin3± Vin2± Vin1± Vin0±
Jumper J8 J7 J6 J5 J4 J3 J2 J1
U-7519ZM
Channel CH0± CH1± CH2± CH3± CH4± CH5± CH6± CH7± CH8± CH9±
Jumper J1 J2 J3 J4 J5 J6 J7 J8 J9 J10
  • Set up the Jumper corresponding to the type of Voltage /  Current and Input / Output for each analog channel.

Voltage Input Selection Jumper (Jumpers default: Voltage

ICP-DAS-U-7524M-CR-UA-I-O-Series-5-Channels-DO-and-2-Port-Ethernet-Switch -FIG-10

  • Voltage Input (Single-ended Mode) Selection JumperICP-DAS-U-7524M-CR-UA-I-O-Series-5-Channels-DO-and-2-Port-Ethernet-Switch -FIG-11
  • Voltage Output Selection JumperICP-DAS-U-7524M-CR-UA-I-O-Series-5-Channels-DO-and-2-Port-Ethernet-Switch -FIG-12
  • Current Input Selection JumperICP-DAS-U-7524M-CR-UA-I-O-Series-5-Channels-DO-and-2-Port-Ethernet-Switch -FIG-13
  • Current Output Selection JumperICP-DAS-U-7524M-CR-UA-I-O-Series-5-Channels-DO-and-2-Port-Ethernet-Switch -FIG-14
  • Thermocouple Input Selection JumperICP-DAS-U-7524M-CR-UA-I-O-Series-5-Channels-DO-and-2-Port-Ethernet-Switch -FIG-15

Documents / Resources

ICP DAS U-7524M CR UA I/O Series 5 Channels DO and 2 Port Ethernet Switch [pdf] User Guide
U-7524M CR UA I O Series 5 Channels DO and 2 Port Ethernet Switch, U-7524M CR UA I O Series, 5 Channels DO and 2 Port Ethernet Switch, 2 Port Ethernet Switch, Ethernet Switch

References