Pin No. Symbol VO Name of port Remark Spec.
I OPF I Customized input Active in low Less than I.15V to active the port. Necessary wiring 3.1V 10k Pull UP. C4
2 RTS 0 Request To Send port Hardware flow control to require transmitting 5.0V 47k Q Pull UP
3 CTS I Clear To Send port Hardware flow control to receive acknowledge for allowance of transmission 5.0V 47k Q Pull UP C3
4 GND GND GND (separation with ground of MIC) GND B4
5 AFO- 0 AF BTL – (Output) port for AF BTL Amp (AB class Amplifier) AF output 8Q load 1.0W @ 5% typ A3

 

6 AFO+ 0 AF BTL + (Output) +port for AF BTL Amp (AB class Amplifier) AF output 8Q load 1.0W 4 5% typ
7 5V 0 5.0V DC output 5V output from the radio 5.0V less than 0.15A ci.10 25°C
8 MDET I Detection of external device Detection for connecting external device in some cases below.
GND with speaker mic in case, open for programing in case, 10k Q with VOX headset in case, 4.7kQ with earphone.
 

 

9 MICE MIC GND GND of MIC A2,AI1
10 NC No Connection
11 RXD I Serial Data Input Data input for programing software, PC commands 5.0V 47k Q Pull UP Cl
12 TXD 0 Serial Data Output Data output for programing software, PC commands 5.0V 47k Q Pull UP C2
13 MIC I MIC Input Input for external MIC Impedance (Input) 2.2k Q 15mVrms *S! 60%Dev Al
14 PTT I PTT External PTT, Active in Low 3.1V 47kQ Pull UP B1

VE-PG3/4

iCOM VE-PG3 Radio Over IP Gateway - Diogram1

Pin No. Description
Al Analog audio output (From the VE-PG4) / Superimpose PTT
A2 Analog GND
A3 Analog audio input (To the VE-PG4) / Superimpose squelch detection
A4 Analog GND
El General control output / Single PTT control i Relay output
B2 Serial communication (Half duplex) / 8 V power supply / Relay output
63 General control input / Single squelch control
B4 Common GND
Cl Serial communication TXD (From the VE-PG4)
C2 Serial communication RXD (To the VE-PG4)
C3 Serial communication RTS (From the VE-PG4)
C4 Serial communication 01-5 (To the VE-PO4)

Samlex MSK-10A Solar Charge Controller - icon4 You can change the configuration of ports B1 to 64 on the VE-PG4 setting screen.

iCOM VE-PG3 Radio Over IP Gateway - Diogram2

iCOM logoIcom America Inc. ©2020

Documents / Resources

iCOM VE-PG3 Radio Over IP Gateway [pdf] Instructions
VE-PG3, VE-PG4, VE-PG3 Radio Over IP Gateway, Radio Over IP Gateway, Over IP Gateway, IP Gateway

References

Leave a comment

Your email address will not be published. Required fields are marked *