ICERIVER logoKAS KSO/PRO
User MANUAL

Product Overview

1.1 Appearance
KS0:

ICERIVER KS0 Pro Mining Crypto Asic Miner Machine Include - AppearanceICERIVER KS0 Pro Mining Crypto Asic Miner Machine Include - Appearance 2

Interface specifications:

Power supply input interface DC power supply interface: 65W, 19V = 3.42A
USB Type-C power supply interface:
Protocol: PD2.0
Input: 65w (max), 20v = 3.25A
USB output interface 5V==0.5A

* The DC power supply interface and USB Type-C power supply interface can not be powered at the same time, only by one interface.

KS0 PRO:

ICERIVER KS0 Pro Mining Crypto Asic Miner Machine Include - KS0 PROICERIVER KS0 Pro Mining Crypto Asic Miner Machine Include - KS0 PRO 2

Interface specifications:

Power supply input interface DC power supply interface: 100W, 19V=6.32V
USB output interface 5V==0.5A

*Indicator Description:

Machine Status Indicator light status
Running Normally Red light steady, green light blink
Network Issues Red light blinks slowly (once per second)
High-temperature Alarm Red light blinks rapidly (3 times per second).

Function

2.1 Start up
2.1.1 Precautions

  • Check whether there is physical interference causing damage to the machine, and beware of electric shock.
  • Please check if the cable connection is firm before powering on, and pay attention to the safety of electricity.
  • Keep the hash board and other parts away from water or exposed to moisture.
  • Please make sure the ambient temperature is between 0-40°C.
  • Please make sure to be in an air-conditioned environment.
  • Please avoid covering the surface of the machine due to the high temperature of the machine surface during operation.
  • Do not place flammable and explosive substances around the machine during operation.
  • Please make sure the humidity of the environment is below 90%.
  • Please keep the environment clean to prevent dust, hair, willow, and other foreign objects from entering the machine and causing damage to the machine.
  • Use a stable voltage.
  • Please place the machine horizontally.
  • The machine, hash board, or board parts being crushed or burned due to an improper environment are not covered by the warranty.
  • Customers should not disassemble the machine by themselves without permission from the ICERIVER after-sales team.

2.1.2 Check before start-up
Preliminary inspection of the machine before operation:

  • Check the appearance of the package for deformation.
  • Check the appearance of the machine for deformation and breakage. Also, check the fan and cable.
  • Check if there is any strange sound in the machine and observe if the heat sink is off.

*Note: Please do not disassemble the machine by yourself. The machine will not be covered by the warranty if the user disassembles the machine without permission.

2.1.3 Boot
Please connect the machine to the Ethernet first, and then plug in the power cord. During the startup process, the red and green status lights will be constantly on. After approximately 1 minute, the green status light will start blinking, indicating that the miner has successfully started.

2.2 Access Machine
2.2.1 Obtain Machine IP

  1. Obtain the IP address of the machine by downloading and unzipping the batch processing tool provided by our company (please refer to the official website to download: https://iceriver.eu/pages/product-manuals-tools
  2. Click the [Detect IP] button and long-press the machine’s button for 1- 2 seconds after the pop-up window to get the machine IP.

ICERIVER KS0 Pro Mining Crypto Asic Miner Machine Include - Obtain Machine IP

2.2.2 Access Machine

  1. Open your web browser (Chrome browser is recommended) and enter the machine’s IP address in the address bar. You will see the following interface.
  2. Use the default username “admin” and the default login password “12345678” to log in to the machine.

ICERIVER KS0 Pro Mining Crypto Asic Miner Machine Include - Access Machine

2.3 Language Switch

  1. Click [Language] in the upper right corner of the page to switch between Chinese and English.

ICERIVER KS0 Pro Mining Crypto Asic Miner Machine Include - Language Switch

To protect your property security, please change the miner password after the first time you turn on the machine.

  1. Click [User Settings], enter the current password and the new password as shown below, and click the [Save] button.ICERIVER KS0 Pro Mining Crypto Asic Miner Machine Include - Change Password
  2. After the password change is completed, you need to log in again with the new password.

2.5 Configuring mining pools and wallets

2.5.1 Add

  1. Go to the [Mining Setting] page and find [Pool Configuration].ICERIVER KS0 Pro Mining Crypto Asic Miner Machine Include - AddYou can configure three mining pools with the following reference example: Pool1: stratum+tcp://kas.eu1.whalepool.com:15120
    Wallet/Worker:ICERIVER KS0 Pro Mining Crypto Asic Miner Machine Include - Worker* The password is optional and can be set or not; it does not affect mining.
  2. Click Save, and a configuration success window will pop up.
  3. After successful configuration, click [Reboot] and wait for the machine to reboot (do not power off during the reboot process).
  4. The information on the home page shows that the pool is ” connected “, which means the pool is successfully connected.

ICERIVER KS0 Pro Mining Crypto Asic Miner Machine Include - Configuring mining pools and wallets

  • The default pool configuration is the configuration of our company when testing. Please configure your own mining wallet address before you start mining. Please do not use the default configuration.
  • If pool 1 is not connected, the machine will automatically connect to pool 2. If pool 2 is not connected, the machine will automatically connect to pool 3.
  • If the configuration fails, you can configure it again and restart it.

The following mining pools are known to be compatible and will be continuously updated:

Whalepool PPLNS stratum+tcp://kas.eu1.whalepool.com:15120
Humpool PPLNS stratum+tcp://kas.eu1.humpool.com:18083
PPLNS stratum+tcp://eu1.kaspa-pool.org:4444
Kaspa-pool SOLO stratum+tcp://eu1.kaspa-pool.org:4441
PPLNS stratum+tcp://pool.eu.woolypooly.com:3112
Woolypooly SOLO stratum+tcp://pool.eu.woolypooly.com:3113
PPLNS stratum+tcp://ru.kaspa.herominers.com:1208
Herominers SOLO stratum+tcp://ru.kaspa.herominers.com:1208
PPLNS stratum+tcp://eu.kaspa.k1pool.com:23112
K1pool SOLO stratum+tcp://eu.kaspasolo.k1pool.com:23114
Accpool PPLNS stratum+tcp://acc-pool.pw:16061
F2pool  PPLNS stratum+tcp://kas-euro.f2pool.com:1400
Kryptex PPLNS stratum+tcp://kas.kryptex.network:7777/6666
PPLNS stratum+tcp://stratum.tw-pool.com:10005
tw-pool.com PPLNS stratum+tcp://stratum2.tw-pool.com:10005
2miners PPLNS stratum+tcp://kas.2miners.com:2121

* The above mining pool information is the mining pool address we used for testing purposes.
Before connecting to the mining pool, please log in to the respective mining pool’s official website and check if the mining pool address has changed.

2.5.2 Remove

  1. Clear the information in [Pool Configuration] and click [Save] to remove the mining pool.

2.5.3 Adjusting fan speed

  1. Find [Hardware Configuration] in [Mining Setting].
  2. Check [Fan Speed].
  3. Select the fan mode or manually adjust the speed, and click [Save] after modification.

ICERIVER KS0 Pro Mining Crypto Asic Miner Machine Include - Adjusting fan speed

  • After powering on, the fan will start only after successfully connecting to the mining pool, and the mining program starts, and the fan speed is full speed by default.
  • The machine will stop mining in sleep mode.
  • After manually changing the fan speed, the fan speed in [Hardware Configuration] will still show 100%.

2.6 View Hashrate Chart

  1. Click [Home] to view the Hashrate Chart.
  • After 5 minutes of connecting to the pool, you can view the machine’s hashrate and hashrate chart. The chart is updated every 5 minutes.
  • Under the Hash board, you can view the machine temperature and fan speed, which can monitor the working status of the machine in real time.

ICERIVER KS0 Pro Mining Crypto Asic Miner Machine Include - View Hashrate Chart

2.7 Network Settings
The factory default is DHCP mode; users can set the IP mode according to their needs.
Set static IP:

  1. Click [IP Settings], select Static in [Protocol], fill in the IP information according to the user, and then click the [Save] button.
  2. After saving the configuration, click [Reboot] and wait for the machine to reboot. Do not power off during the reboot.

ICERIVER KS0 Pro Mining Crypto Asic Miner Machine Include - Network Settings

2.8 Firmware Upgrade
When the official website releases a new upgrade package, download it and upgrade it via the Web.

  1. Click [Firmware Upgrade], select the official upgrade package, and click [Upgrade].
  2. Wait for the pop-up window to show success and then click [Reboot] and wait for the machine to reboot (do not power off during the reboot process).
  3. After reboot, the firmware upgrade is successful.

ICERIVER KS0 Pro Mining Crypto Asic Miner Machine Include - Firmware Upgrade

2.9 Factory Reset
When the machine has abnormal conditions, you can restore the factory settings through the Button on the machine.

  1. After the green status light starts blinking following the power-up (1 minute after power on), press and hold the Button for 20 seconds until the red status light starts blinking. Waiting until the red status light stops blinking and waiting for the machine to reboot. Do not power off the machine during the reboot process.
  2. After the machine reboots, reconfigure the mining pool and wallet to resume mining.

2.10 Shutdown/Reboot
2.10.1 Shutdown

  1. Power off by unplugging the Power Cord.

2.10.2 Reboot

  1. Click [Reboot] in the bottom right corner of the home page, then click [OK] to confirm, then reboot the machine.

* Note: Do not power off the machine during the reboot process.

ICERIVER KS0 Pro Mining Crypto Asic Miner Machine Include - Reboot

Common Faults and Solutions

3.1 Faults Solutions
3.1.1 Power Supply

  • Connect the power supply, and the red and green status lights do not light up:
    Check whether the power connector is loose or off, and whether the power cord is inserted tightly.

3.1.2 Network

  • Network port light does not light up:
    Check if the network port is plugged in.

3.1.3 Fan

  • The fans do not turn on after power is applied:
    Check if the mining pool is successfully connected.

3.1.4 High Temperature

  • Machine temperature is too high:
    1. Check that the machine is not covered with.
    2. Check if the machine is placed in an environment with air convection.
    3. External fan of not more than 5V==0.5A for cooling via USB port.

3.1.5 Hashrate does not meet the target hashrate

  • Hashrate does not match the target hashrate:
    1. Check whether the surface temperature of the machine is too high. High temperature will trigger high temperature protection and cause the machine to shut down. Please place the machine in an air convection environment or an external fan to cool down the temperature.
    2. Short-term hashrate fluctuations, please observe the 12-hour average hashrate.
  • The difference between the Web hashrate and the mining pool hashrate is large:
    Check whether the network connection is normal.

3.1.6 Unable to enter the Web operation page

  • The browser displays 404 after entering the machine IP:
    Reboot the machine and re-enter the Web operation page.

ICERIVER logo