Specifications

  • Model: IS-TH2ER.2 | MTH2ERA01
  • Certificate of Conformity: EPS 25 ATEX 1 206 X
  • Manufacturer: i.safe MOBILE GmbH
  • IP-Protection: Yes

Product Usage Instructions

  • Safety Instructions
    Read the Safety Instructions and Operating Manual carefully before using the device to prevent accidents, injuries, or damage.
  • Connection
    The device should only be connected outside hazardous areas to the IS540.2 via the ISM interface. Securely fasten the device to the ISM interface when used in hazardous areas.
  • IP-Protection
    To maintain IP-protection, ensure all gaskets are functional, and there are no large gaps between housing parts and the battery. This protects the device from dust and water.
  • Charging
    Charge the device outside hazardous areas using IS-DCTH1.1 to avoid any potential risks associated with charging in hazardous environments.
  • Impacts
    Avoid exposing the device to aggressive substances, high-impact energy, excessive UV light, or high electrostatic charges. Protect the device from physical damage.
  • Faults and Damages
    If you suspect any compromise to the device’s safety, remove it from use immediately. Signs of compromised safety include malfunctions, physical damage to the housing, exposure to excessive loads, improper storage, or illegible markings.

i-safe-MOBILE-IS-TH2ER-2-Handheld-Barcode-Scanner-fig- (1)

EX MARKINGS

ATEX:

  • II 3G Ex ic op is IIC T4 Gc
  • II 3D Ex ic op is IIIC T135°C Dc Certificate of Conformity:
  • EPS 25 ATEX 1 206 X
  • CE-designation:

IECEx:

  • Ex ic op is IIC T4 Gc
  • Ex ic op is IIIC T135°C Dc
  • IECEx Certificate: IECEx EPS 25.0054X

Temperature range: 

  • 20 °C ≤ Ta ≤ +55 °C (EN/IEC 60079-0)
  • 10 °C … +55 °C (EN/IEC 62368-1)

Manufactured by:

  • i.safe MOBILE GmbH
  • i_Park Tauberfranken 10 97922 Lauda-Koenigshofen Germany

Read these Safety Instructions and the Operating Manual carefully before using the device. If you do not follow these instructions or do not understand them, this could lead to death, severe injuries and damage to the device. You can find the current Operating Manual at www.isafe-mobile.com/en/support/downloads

Only trained users who are qualified in the use of Ex devices in explosion-hazardous areas and who have read and understood the Operating Manual may use this device.

Safety Instructions

  • Follow all instructions given on the device and on the packaging.
  • Follow local safety regulations.
  • Only use the device in explosion-hazardous areas of zones 2/22 or outside of explosion-hazardous areas.
  • Only connect the device outside explosion-hazardous areas to the ISM interface of the IS540.2. Before entering an explosion-hazardous area with the device,
    • make sure that the device is securely fastened to the ISM interface of the IS540.2,
    • make sure that no gap can be seen between the two halves of the device,
    • make sure the device is not damaged, and
    • make sure that all the labels on the device are readable.
  • If you use the device in an explosion-hazardous area,
    • Do not loosen the screws on the device,
    • do not connect any accessories to the device,
    • do not open any interface cover,
    • do not charge the IS540.2,
    • do not open the device,
    • Do not damage the device.
  • Switch off the device immediately and leave the explosion-hazardous area without delay if
    • malfunctions occur on the device,
    • You have damaged the housing of the device,
    • You have exposed the device to excessive loads,
    • The device has been stored improperly,
    • The labels on the device are no longer readable.
  • Laser Light. Do not stare into the beam class 2 laser product 510 – 530 nm, 1 mW.
  • Do not modify the device structurally.
  • Do not expose the device to high temperatures.
  • Do not expose the device to strong UV radiation.
  • Do not expose the device to processes with high electrical charges.
  • Do not expose the device to aggressive acids or bases.
  • Do not open the device or carry out any repairs yourself.

EX-RELEVANT SAFETY REGULATIONS

Use of this device assumes that the operator observes the conventional safety regulations and has read and understood the Operating Manual, Safety Instructions and certificate.
When used in explosion-hazardous areas, the following Safety Instructions must also be complied with:

CONNECTION

  • The device may be connected only outside ex-hazardous areas to the IS540.2 via the ISM interface.
  • The device must be securely fastened to the ISM interface when used in ex-hazardous areas.

IP-PROTECTION

  • To ensure the IP-protection, it has to be ensured that all gaskets are present and functional.
  • There must be no large gap between the two halves of the housing and between the battery and the housing.

CHARGING

The IS540.2 may only be charged outside explosion-hazardous areas via the IS-DCTH1.1.

IMPACTS

  • The device may not be exposed to any aggressive acids or alkalis.
  • The device must be protected from impacts with high impact energy, against excessive UV light emission and high electrostatic charge processes.

CONDITIONS OF USE

  • The permitted ambient temperature range is -20 °C to +55 °C (-4 °F to +131 °F).
  • The device may only be used in zones 2 or 22.

FAULTS AND DAMAGES

If there is any reason to suspect that the safety of the device has been compromised, it must be withdrawn from use and removed from any ex-hazardous areas immediately. Measures must be taken to prevent any accidental restarting of the device. The safety of the device may be compromised if, for example:

  • Malfunctions occur.
  • The housing of the device shows damage.
  • The device has been exposed to excessive loads.
  • The device has been stored improperly. Markings or labels on the device are illegible.

We recommend that a device displaying errors or in which an error is suspected be sent back to i.safe MOBILE GmbH to be checked.

  • IS-TH2ER.2 | MODEL MTH2ERA01
  • Document No. 1106MM02REV00
  • Version: 2025-12-16
  • i.safe MOBILE GmbH

Germany

www.isafe-mobile.com/en/support/downloads

CONTACT/SERVICE CENTRE

FOR FURTHER QUESTIONS, PLEASE CONTACT OUR SERVICE CENTRE:

EU Declaration of Conformity

according to directive 2014/34/EU, 2014/30/EU, 2011/65/EU (2015/863/EU)

The company i.safe MOBILE GmbH declares under its sole responsibility that the product to which this declaration relates is in accordance with the provisions of the following data, directives and standards:

Name & address of the manufacturer in the EU i.safe MOBILE GmbH i_Park Tauberfranken 10

97922 Lauda – Koenigshofen

Germany

Description of the device Intrinsically safe Trigger Handle

Eigensicheres Trigger Handle

 

Type / Typ: IS-TH2ER.2 Model / Modell: MTH2ERA01Ex–marking

g

 

II 3G Ex ic op is IIC T4 Gc

II 3D Ex ic op is IIIC T135°C Dc

Conformity statement 2014/34/EU issued by EPS 25 ATEX 1 206 X

 

Bureau Veritas Consumer Products Services Germany GmbH

Businesspark A96

86842 Tuerkheim, Germany

identification number / Kenn-Nummer: 2004

Applied harmonised standards EN IEC 60079-0:2018; EN 60079-11:2012

IEC 60079-11:2023; EN 60079-28:2015

Conformity statement 2014/30/EU EN 55032:2015+A1:2020;
EN 55035:2017+A11:2020
Conformity statement 2015/863/EU amending IEC 62321-2:2013; IEC 62321-3-1:2013;
2011/65/EU IEC 62321-5:2013; IEC 62321-4:2013+AMD1: 2017;
IEC 62321-7-1:2015 ; IEC 62321-7-2:2017;
2011/65/EU IEC 62321-6:2015; IEC 62321-8:2017
CE Marking CE

i-safe-MOBILE-IS-TH2ER-2-Handheld-Barcode-Scanner-fig- (2)

FAQs

W hat should I do if I notice physical damage to the device?

If the device shows any signs of physical damage, stop using it immediately and contact i.safe MOBILE GmbH for further assistance.

Can the device be charged in hazardous areas?

No, the device should only be charged outside hazardous areas using the specified charger to ensure safety.

Documents / Resources

i safe MOBILE IS-TH2ER.2 Handheld Barcode Scanner [pdf] Instruction Manual
MTH2ERA01, IS-TH2ER.2 Handheld Barcode Scanner, IS-TH2ER.2, Handheld Barcode Scanner, Barcode Scanner, Scanner

References

Leave a comment

Your email address will not be published. Required fields are marked *