HYSEN-logo

HYSEN HY02DB-WIFI Wifi Plug In Thermostat

HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (17)

Product Specifications

  • Feature: WIFI Plug In Thermostat
  • Description of icons and buttons: Programming mode, Manual mode

Product Information

The WIFI Plug In Thermostat allows you to control the temperature of your home remotely through a mobile app. It features various modes such as temporary manual mode and holiday mode for customized heating settings. The thermostat also supports WIFI connectivity for easy control.

Usage Instructions

Key Functions

  • Short press: Set programming mode and manual mode
  • Long press (3-5 seconds): Turn off thermostat / Connect WIFI / Lock or unlock
  • Press: Turn on thermostat
  • Decrease key: Long press to lock or unlock
  • Increase key: Enter setting interface

Programming Mode
In programming mode, press to enter time setting or temporary manual mode. Adjust settings using the keys and press to confirm.

Weekly Programmable Setting
Choose from 5+2, 6+1, or 7-day models for programming. Enter advanced options to set period settings.

Holiday Mode Setting
Set holiday days and temperature for countdown mode. Exit holiday mode by pressing the corresponding key.

Advanced Options
Access advanced options by long-pressing when the thermostat is turned off. Adjust settings and save changes by pressing the keys accordingly.

FAQ

  • Q: How do I connect the thermostat to WIFI?
    • A: Long press the key combination to activate WIFI distribution network icon and follow the instructions on the app to add the thermostat.
  • Q: How do I set the temperature in manual mode?
    • A: Use the increase and decrease keys to adjust the temperature while in manual mode.

WIFI Plug In Thermostat User Manual
Many thanks for your selection of our products and services, and also for your trust and support to us.

HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (1)

Feature

  • EU,FR,AU,USA,IT etc socket for choice
  • 0.5°C accuracy keeps temperature within the level you set.
  • Children lock to prevent misoperation by children
  • weekly programming mode includes: 5+2, 6+1, 7 days three modes, and can be DIY programming.
  • The classic holiday mode allows you to enjoy a comfortable temperature during your holiday.
  • Temporary manual mode: In the automatic mode, set the temperature, the thermostat will run for a period according to the set temperature, and then return to the automatic mode

Product Specifications

  • Power:230Vac 50/60HZ
  • Probe Sensor: NTC(10k)1%
  • Current: 10A
  • Limit temperature range: 1~70°C
  • Default setting temperature range: 5~35°C
  • Max. control accuracy: ±0.5°C

Feature Description of icons and buttons

  • HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (2)Programming mode
  • HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (3)Manual mode
  • HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (4)Temporary manual mode
  • HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (5)Holiday mode, Holiday days and temperature can be set to run in countdown mode
  • HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (6)Heating, icon disappears means stop heating
  • HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (7)WIFI connection, flashing EZ distribution mode
  • HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (8)Wifi status: Disconnection
  • HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (9)Cloud icon: flashing, add thermostat to APP with AP mode
  • HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (10)Children lock

Key Function

HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (11)

  • Short press to set programming mode and manual mode
  • Long press 3-5 seconds to turn off thermostat
  • Press to turn on thermostat HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (12)
  • On turn on state,long press 3-5 seconds to connect WIFIHYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (13)
  • Decrease key
  • Long press to lock or unlock
  • HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (14)Increase key
  • On turn on state,long press 3-5 seconds to enter setting interface
  • On turn off state,long press 3-5 seconds to enter advanced options

In the programming mode, press HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (15)enter into temporary manual mode

Time setting
On turn on state ,long press HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (14)3-5 seconds to enter setting interface, press HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (15) to choose 1,press to HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (11)enter time setting ,then press HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (11)to choose :hour ,minute ,week, pressHYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (15) to adjust value. After finishing, press HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (11)to return.

Weekly Programmable Setting
5+2 (factory default), 6+1 and 7 models 6 times period setting for user choice .Choose mode in the advanced options. On turn on state, long press HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (14)3-5 seconds to enter setting interface, press  or to choose 2,press to enter programming setting ,then press to choose: hour ,minute, temperature, press HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (15) to adjust value. After finishing, pressHYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (11) to return.

HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (16)

The optimum comfort temperature is 18°C-22°C

Holiday mode setting
On turn on state, long pressHYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (14) 3-5 seconds to enter setting interface, press HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (15) to choose 3,pressHYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (11) to enter holiday mode setting ,then pressHYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (11) to choose: days and temperature, press HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (15)to adjust value. After finishing ,press HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (11)to return

Advanced options
On turn off state, long press HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (14)3-5 seconds to enter advanced options, short pressHYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (11) to choose the option, press HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (15)to adjust value. After setting finished ,keep about 10 seconds will automatic save and exit.

NO Setting Options Data Setting Function Factory Default
A1 Measuring TemperatureCalibration -9-+9°C -1℃
A2 Start/stop working temperaturedifference setting 0.5-2.5°C 1°C
A3 Low temperature protection setting 1.  1-10°C2. Exceed 10°C, screen display, low temperature protection was canceled. 5°C
A4 Setting temperature minimum limit 1-10°C 5°C
A5 Setting temperature maximum limit 20-70°C 35°C
A6 Run weekly 0:(5+2)/1:(6+1)/2:(7days) 0:(5+2)
  programming

selection

   
A7 Run ventilation mode setting(open

window)

  1. :【  — 】close ventilation mode(press HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (14)to increase temperature and open this mode)
  2. :10-20°C
 
A8 Working time of

ventilation mode

5-40minutes 20
A9 Backlight brightness

when sleep

1:0-8(0 close,1 Darkest,8 brightest ) 1
AA Reset factory setting Display A o, press HYSEN-HY02DB-WIFI-Wifi-Plug-In-Thermostat-image (14)       until show all icons  

Wiring and installation instructions

  1. Read these instructions carefully. Failure to follow these instructions can result in damage to the product or a hazardous situation.
  2. Confirm the maximum load given in the instructions and product, to ensure the product is right for your application.
  3. The installer must be a trained and experienced service technician.
  4. After the installation completed, follow the steps in these instructions.

Warning

  • Live work can cause a short circuit or damage the device
  • Disconnect power supply before installation

Documents / Resources

HYSEN HY02DB-WIFI Wifi Plug In Thermostat [pdf] User Manual
HY02DB-WIFI Wifi Plug In Thermostat, HY02DB-WIFI, Wifi Plug In Thermostat, Plug In Thermostat, In Thermostat, Thermostat

References

Leave a comment

Your email address will not be published. Required fields are marked *