Quick Start Guide
Sprite TL
Push Button Mode
Note: The following instructions will serve as a start-up programming base for the installation of a Sprite TL in Push Button Mode.
- To enter the programming menu press and hold the
key for 2 seconds.
- The display will show 000 with the left 0 flashing.
- Press the
key to change the digit to a 1.
- Press the
key to advance to the middle digit.
- Press the
key 2 times to change the digit to a 2.
- Press the
key to advance to the right digit
- Press the
key 3 times to change the digit to a 3.
- With the display showing 123 press the
key.
Prime the Pumps and Operation Mode
- The display will show P-1 with the 1 flashing. (pump 1)
- Press the
key to prime pump 1, press again to stop.
- Press the
key to select P-2 (pump 2).
- Press the
key to prime pump 2, press again to stop.
Clear Load Count and Operation Mode choice
- Press the
key to display “Clr”. The screen will toggle between the current load count and “Clr” .
- Press the
key to clear the load count.
- Press the
key to display “oP”. (operation mode) The screen will toggle between the current operation mode and “oP”.
- Press the
key to adjust the operation mode. Choices are “Pb” for Push Button mode (select this choice), or “oc” for Occurrence mode, or “Au” for Automatic mode.
Program Dispenser Lock Out Period
- Press the
key to set the “oP” & advance to “LP”.
- Press the
key to display “LP”(Lockout Period).
- Press the
&
key to adjust the desired “LP”.
- Press the
key to set the Lockout Period .
Program Pump Run Time
- Press the
key to display F-1 with the 1 flashing.
- Press the
key to select a Formula to program.
- Press the
key when desired Formula is displayed.
- Press the
key to start & stop Pump 1 run time.
- Press the
key to select P 2 (Pump 2).
- Press the
key to start & stop Pump 2 run time.
Program Pump Delay Time
- Press the
key to display “d1” with the 1 flashing. (d1 = pump 1 delay time, d2 = pump 2 delay time).
- Press the
key to select a pump to delay.
- Press the
key to display delay time.
- Press the
&
key to adjust the desired delay time.
- Press the
key to set the delay time.
Program Additional Formulas
- Press the
key and to display “Fin”.
- Press the
key to display F-1 with the 1 flashing.
- Press the
key to select another Formula to prog. or,
- Press the
key to display “Fd”.
If using washing machine signals, Program Filter Duration time
- Press the
key to select a Filter Duration time.
- Press the
&
key to adjust the desired delay time.
- Press the
key to set the “Fd”.
Program User Prime Pumps
- Press the
key to display “Upr (user prime). The screen will toggle between the current setting and “Upr”.
- Press the
key to toggle “OFF” or “ON”.
Program Change Password
- Press the
key to display “Pin”.
- Press the
key if you want to change the “Pin”.
- Press the
&
key to change the desired NEW “Pin”.
- Press the
key to set the “Pin”.
- Press the
key to display “End”.
- Press the
key to exit Programming Menu.
Warranty
Limited Warranty
Seller warrants solely to Buyer the products will be free from defects in material and workmanship under normal use and service for a period of one year from the date of completion of manufacture. This limited warranty does not apply to (a) hoses; (b) products that have a normal life shorter than one year; or (c) failure in performance or damage caused by chemicals, abrasive materials, corrosion, lightning, improper voltage supply, physical abuse, mishandling or misapplication. In the event the products are altered or repaired by Buyer without Seller’s prior written approval, all warranties will be void. No other warranty, oral, expressed or implied, including any warranty of merchantability or fitness for any particular purpose, is made for these products, and all other warranties are hereby expressly excluded. Seller’s sole obligation under this warranty will be, at Seller’s option, to repair or replace F.O.B. Seller’s facility in Cincinnati, Ohio any Products found to be other than as warranted.
Limitation of Liability
Seller’s warranty obligations and Buyer’s remedies are solely and exclusively as stated herein. Seller shall have no other liability, direct or indirect, of any kind, including liability for special, incidental, or consequential damages or for any other claims for damage or loss resulting from any cause whatsoever, whether based on negligence, strict liability, breach of contract or breach of warranty.