FIG 19.JPG

HYDRO-RAIN GC1 Gateway Controller Instruction Manual

FIG 1 HYDRO-RAIN GC1 Gateway Controller Instruction.JPG

888.203.1179
915 Overland Street, North Salt Lake, UT 84054, USA
www.HydroRain.com

Welcome to the Hydro-Rain Family

Congratulations on the purchase of the Gateway Controller

Time is money, so Hydro-Rain products are designed to save you both. Whether it is programming a controller, installing a device, or adjusting the system, Hydro-Rain products are simply faster and easier to use.

Note IconThe Gateway Controller must be installed by a trained professional.

 

B-hyve Ag

The B-hyve Ag app is designed for for both growers and dealers to easily manage connected irrigation controllers, users, and accounts.

Download the B-hyve Ag app to get started.

FIG 2 Download the B-hyve Ag app.JPG

 

Need Help?

Contact B-hyve Ag Product Support : 1-801-407-5255

For help setting up or operating the Gateway Controller please call the Hydro-Rain Product Support team. Our friendly staff is here to assist with all the technical needs of the installer or maintenance crew.

 

Getting Started

Prior to installing the new Gateway Controller, make sure the the product is intact and undamaged. If any parts are missing or broken please call 1-801-407-5255 as soon as possible.

Part List

FIG 3 Part List.JPG

Recommended Tools

FIG 4 Recommended Tools.JPG

 

Mounting Options

Using the mounting holes located at the top and bottom of the controller, attach the unit to a pole, wall, or panel using the provided screws.

FIG 5 Mounting Options.JPG

 

Helpful Hints

 

Mini Screwdriver
A mini screwdriver is provided to be used on the low-voltage green terminals. It can be housed in the provided slot on the door.

FIG 6 Mini Screwdriver.JPG

Knockout

The knockouts on the controller can easily be removed by inserting a flathead screwdriver into the slot and rotating.

FIG 7 Knockout.JPG

Coil Cell Battery
Insert the provided coil cell battery into the designated slot on the Gateway Controller.

Accessory Adapter
An accessory adapter is provided to allow B-hyve accessories to be added to the Gateway Controller. There is no need to install the accessory adapter if accessories will not be added.

Step 1: Remove the far-right knockout on the Gateway Controller.
Step 2: Connect the accessory adapter into the 4-pin receptacle.
Step 3: Remove the paper on the accessory adapter and insert the accessory adapter into the far-right knockout.

 

Connectivity Options

The app will help you configure the connectivity during setup.

Cellular
Slide the B-hyve Cell Module into the cell module slot. (Fig. 3) (Cell Module Sold Separately. SKU: 04450)

Wi-Fi
Ensure the Gateway Controller is within Wi-Fi range of the router, typically 150 ft. (Fig. 4)

Note Icon 5150-5250MHz Wi-Fi connections are not available in Canada if mounted outdoors.

FIG 8 Connectivity Options.JPG

Ethernet
Insert ethernet cable into the marked slot on the controller.

Client Radio*
Insert cable into the marked slot on the controller. (Client Radio Sold Separately)
* Requires AG-CPB (Sold Separately SKU: 25024)

FIG 9Connectivity Options.JPG

 

Wiring – Power Options

 

Line Power

FIG 10 Line Power.JPG

24VDC

FIG 11 24VDC.JPG

Wiring – General

warning icon WARNING: TURN OFF THE POWER TO THE CONTROLLER BEFORE WORKING WITH THE TRANSFORMER AND WIRING. TURNING THE ON/OFF SWITCH DOES NOT TURN OFF THE POWER INTO THE TRANSFORMER. ALWAYS FOLLOW APPLICABLE ELECTRICAL CODES. ELECTRICAL WORK MAY REQUIRE A LICENSED ELECTRICIAN.

Pump

FIG 12 Pump.JPG

The Gateway Controller relays are rated for up to 220VAC, 10amps, and single phase. For anything else, use a contactor.

Flow Meters

FIG 13 Flow Meters.JPG

The Gateway Controller can read flow meters with a pulse output and has an 18V pull-up on the signal input.

 

Wiring – Transducers

Any combination of 0-10V or 4-20mA type transducers is acceptable.

Voltage

FIG 14 Voltage.JPG

The Gateway Controller accepts voltage inputs between 0-10VDC.

4-20mA

FIG 15 4-20mA.JPG

 

Product Warranty

 

Hydro-Rain warrants to its trade customers that its products will be free from original defects in material and workmanship (commencing on the date of sale to the trade customer) for a period of three-years, or five, (for Premier Contractors). For customers outside of the United States, this warranty may vary by geographical location.

If there are further questions about installation, please contact Hydro-Rain via phone 1-888-493-7672 Monday-Friday MST from 7:00am to 7:00pm and Saturday-Sunday from 7 am to 5 pm.

Or try our website, www.hydrorain.com.

This warranty applies only to Hydro-Rain products, which are installed as specified and used as intended for commercial irrigation purposes. The warranty applies only to offered products, which have not been altered, converted, damaged, misused, or misapplied. This warranty does not cover products adversely affected by the system into which the products are incorporated, including improperly designed, installed, operated, or maintained systems or systems using water containing corrosive chemicals, electrolytes, sand, dirt, silt, rust, and scale. This warranty does not cover component failure caused by lightning strikes, electrical power surges, or damage caused by freezing environments. Hydro-Rain’s liability is limited to the repair and/or replacement at Hydro-Rain’s sole discretion, of products that are returned prepaid through the trade customer to the factory and found by Hydro- Rain to be defective, but in no event shall Hydro-Rain’s liability exceed Hydro-Rain’s selling price of the product. Hydro-Rain makes no other warranties, expressed or implied. No representative, agent, or distributor or other persons have the authority to waive, alter, or add to the printed provisions of this warranty, or make representation of warranty not contained herein.

 

FCC & IC Statement

FC icon

This device complies with Part 15 of the FCC Rules and Industry Canada license exempt RSS standards. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

FCC Warning: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  •  Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help

This device meets the FCC and IC requirements for RF exposure in public or controlled environments.
The end user is advised to maintain a distance of 20 cm from the controller and any personnel to ensure compliance with RF exposure regulations.

This Class B digital apparatus complies with Canadian ICES-003

FIG 16.JPG

FIG 17 .JPG

 

EU & UK Declaration of Conformity

FIG 18 EU & UK Declaration of Conformity.JPG

Note icon CAUTION: DISPOSE OF USED BATTERIES ACCORDING TO THE BATTERY MANUFACTURER’S INSTRUCTIONS.

warning icon WARNING: RISK OF FIRE, EXPLOSION, AND ELECTRIC SHOCK. REPLACE BATTERY WITH CR2032 ONLY. USE OF A DIFFERENT BATTERY HAS THE POTENTIAL FOR A RISK OF FIRE, EXPLOSION, AND ELECTRIC SHOCK.

warning icon WARNING: DO NOT INGEST BATTERIES. CHEMICAL BURN HAZARD. KEEP BATTERIES AWAY FROM CHILDREN.

warning icon WARNING: THIS PRODUCT CONTAINS A LITHIUM BUTTON/COIN CELL BATTERY.

warning icon WARNING: IF A NEW OR USED LITHIUM BUTTON/COIN CELL BATTERY IS SWALLOWED OR ENTERS THE BODY, IT CAN CAUSE SEVERE INTERNAL BURNS AND CAN LEAD TO DEATH IN AS LITTLE AS 2 HOURS.

warning icon WARNING: BATTERY MUST BE REMOVED FROM THE CONTROLLER BEFORE IT IS SCRAPPED.

FIG 19.JPG

 

888.203.1179
915 Overland Street, North Salt Lake, UT 84054, USA
www.HydroRain.com

 

Read More About This Manual & Download PDF:

Documents / Resources

HYDRO-RAIN GC1 Gateway Controller [pdf] Instruction Manual
ML6GC1, gc1, GC1 Gateway Controller, GC1, Gateway Controller, Controller

References