Hilti HDA-P/-PF/-PR M16 Anchor Installation Instructions
Product Overview
This document provides operating instructions for the Hilti HDA-P/-PF/-PR M16 anchor system. It details the technical specifications and step-by-step installation procedures for professional construction applications.
Technical Specifications
Product | hmin [mm] | df [mm] | hs [mm] | d [mm] | SW [mm] | Tinst [Nm (ft-lb)] |
---|---|---|---|---|---|---|
HDA-P/-PF/-PR M16 x 190/40 | 0-40 | 24 | 2-8 mm (1/16" - 5/16") | 24 | - | 120 Nm (89 ft-lb) |
HDA-P/-PF/-PR M16 x 190/60 | 0-60 | 24 | 2-8 mm (1/16" - 5/16") | 24 | - | 120 Nm (89 ft-lb) |
Note for TE 70: For use with Hilti TE 70 hammer drill, minimum embedment depth (hmin) must be ≥ 300 mm (11.8"). Compatible drill bits and tools include TE-Y HDA-B 30 x 190, TE-Y HDA-ST 30-M16, TE 60-(04), and TE 70-(03)* / TE 70-(04)*.
Installation Steps
Step 1: Drilling the Hole
Drill a hole in the base material using a suitable Hilti hammer drill (e.g., TE 60, TE 70) and the specified drill bit (df = 24 mm). Ensure the hole is drilled perpendicular (90°) to the surface. The drill bit depth stop should be set to the required hole depth (hs).
⚠️ Important: Ensure correct drill bit diameter and angle.
Step 2: Cleaning the Hole
Thoroughly clean the drilled hole using a Hilti cleaning brush and blower. Remove all dust and debris from the hole to ensure proper anchor function.
▶️ [Cleaning tool action]
Step 3: Inserting the Anchor
Insert the HDA-P/-PF/-PR M16 anchor into the cleaned hole. Ensure it is inserted straight and to the correct depth. Do not force the anchor.
❌ [Incorrect insertion symbol]
Step 4: Setting the Anchor
Use a Hilti setting tool (e.g., TE-Y HDA-B 30 x 190, TE-Y HDA-ST 30-M16) to drive the anchor into the hole. The tool should be aligned correctly with the anchor.
-> [Setting tool action]
Step 5: Initial Tightening
Apply initial torque to the anchor using a suitable wrench. This step helps seat the anchor correctly before final tightening.
? [Rotation symbol]
Step 6: Checking Installation Depth and Flushness
Visually inspect the installed anchor. Ensure the anchor is set to the correct depth (hs) and is flush with the base material surface, as indicated by the markings on the anchor.
⚠️ Important: Check correct depth (hs) and flushness.
✔️ [Correct installation visual]
Step 7: Attaching Fixture
Place the fixture to be attached onto the installed anchor. Align the fixture's mounting holes with the anchor's thread.
-> [Fixture placement]
Step 8: Final Tightening
Tighten the anchor nut using a calibrated torque wrench to the specified installation torque (Tinst = 120 Nm / 89 ft-lb). Ensure the correct wrench size (SW) is used.
[Torque wrench action] ⚠️ Important: Apply specified torque.
SW: [Wrench size indicator]
Safety Information
ご使用前に取扱説明書を必ずお読み下さい。
(Please read the instruction manual carefully before use.)
CE [CE marking]
XX OX [Certification marks]