KÒMAND-AKSÈ-LOGO

COMMAND ACCESS MLRK1-jac12 Sòti Aparèy Motor Twous

COMMAND-ACCESS-MLRK1-jac12-Exit-Device-Motor-Kit-PRODUCT

ANTRE ENSTRIKSYON

Kòmand Aksè MLRK1 a se yon twous retraksyon motè ki kapab enstale sou teren pou:

  • MLRK1-JAC 12 – Jackson 1285, 1286 ak 1295 aparèy seri
  • MLRK1-KAW17 - Kawneer 1686 ak 1786 aparèy seri
  • MLRK1-AHT – AHT 8 ak 9 seri aparèy

Twous Gen ladann

COMMAND-ACCESS-MLRK1-jac12-Exit-Device-Motor-Kit-FIG-2

  • A. (1) 60140 MOTÈ KIT Asanble
  • B. (1) 50516 END CAP LINK
  • C. (1) 50944 HARNESS POUVWA

Videyo enstalasyon

COMMAND-ACCESS-MLRK1-jac12-Exit-Device-Motor-Kit-FIG-3

SPECIFICATIONS

  • Antre Voltage: 24VDC +/- 10%
  • KOURAN RETRACTION LATCH MWAYEN: 900 mA
  • Kouran kenbe mwayèn: 215 ma
  • Kalib fil: Minimòm 18 kalib
  • Fil dirèk kouri - pa gen rle oswa inite kontwòl aksè nan-ant ekipman pou pouvwa ak modil

Si ou vle bati-an rex

  • SPDT - Rated .5a @ 24VDC
    • vèt = komen (C)
    • Ble = nòmalman louvri (NON)
    • gri = nòmalman fèmen (NC)

Pwovizyon pou pouvwa rekòmande: Sèvi ak yon ekipman pou pouvwa klas 2 ki limite

Tout aparèy sòti Kòmandman Aksè ak twous ki enstale sou teren yo te byen teste sik ak ekipman pou pouvwa Command Access nan faktori nou an. Si w gen plan pou w sèvi ak yon ekipman pou pouvwa ki pa kòmand, li dwe yon ekipman pou pouvwa lineyè filtre & reglemante.

Enstriksyon Enstalasyon

COMMAND-ACCESS-MLRK1-jac12-Exit-Device-Motor-Kit-FIG-4

  • 1. Retire bouchon fen aparèy, plak filler, brcket mòn, ak pouse bouchon bout pad.COMMAND-ACCESS-MLRK1-jac12-Exit-Device-Motor-Kit-FIG-5
  • 2a. Kalite 1 (Jackson Kalite)COMMAND-ACCESS-MLRK1-jac12-Exit-Device-Motor-Kit-FIG-6
  • 2b. Kalite 2 (AHT / Kalite Kawneer)COMMAND-ACCESS-MLRK1-jac12-Exit-Device-Motor-Kit-FIG-7
  • 3. Re-enstale End Cap ak New End Cap Link nan lojman pouse pad la.COMMAND-ACCESS-MLRK1-jac12-Exit-Device-Motor-Kit-FIG-8
  • 4. Glise asanble motè nan kanal baz tren an (a). Akòz enkonsistans extrusion, fen ke twous la ka kontakte lojman an (b). Nan evènman sa a, dekole de vis MM5 yo, glise twous la rès la nan plas la, Lè sa a, sere boulon vis MM5 yo (c).COMMAND-ACCESS-MLRK1-jac12-Exit-Device-Motor-Kit-FIG-9
  • 5. Verifye ke End Cap Link la nan pozisyon ki kòrèk la (a) epi sere vis byen sere (b). Apre sa, teste fonksyon epi ajiste kote PTS (c) pou chak paj 4 enstriksyon yo. Yon fwa yo fini, enstale sipò dèyè, plak filler, ak bouchon final aparèy pou fini enstalasyon an (d).

Enfòmasyon teknik

COMMAND-ACCESS-MLRK1-jac12-Exit-Device-Motor-Kit-FIG-10

Anviwònman PUSH TO SET (PTS)

Anvan w fini, asire w ke w teste fonksyon yo epi reset PTS, si sa nesesè

COMMAND-ACCESS-MLRK1-jac12-Exit-Device-Motor-Kit-FIG-11

  • Etap 1 - Pou antre nan mòd PTS: Peze bouton MM5 epi aplike pouvwa. Aparèy la pral emèt 1 BIP KOUT. Kontinye kenbe bouton an jiskaske pouvwa a retire.
  • Etap 2 - Peze epi kenbe pouse pad 95% nan vwayaj konplè, Lè sa a, aplike pouvwa (sa vle di prezante kalifikasyon an bay lektè a).
  • Etap 3 - Kontinye kenbe pad pouse deprime, aparèy la pral emèt LONG Bip. Apre bip la sispann ak pouvwa yo te retire, lage pad la. Ajisteman an fini. Teste vwayaj la pou verifye si pad pouse a anlè 95%* epi pòt la klè pou louvri. Si ou pa renmen ou repete 3 etap yo.
    • * 100% kousinen pouse retrè ka mare pandan kondisyon ekspansyon/kontraksyon. 95% se ideyal.

Depanaj ak dyagnostik

COMMAND-ACCESS-MLRK1-jac12-Exit-Device-Motor-Kit-FIG-12

Kontakte

COMMAND-ACCESS-MLRK1-jac12-Exit-Device-Motor-Kit-FIG-1

Dokiman / Resous

COMMAND ACCESS MLRK1-jac12 Sòti Aparèy Motor Twous [pdfManyèl Enstriksyon
MLRK1-jac12 Kit Motè Aparèy Sòti, MLRK1-jac12, Twous Motè Aparèy Sòti, Twous Motor Aparèy, Twous Motor, Twous

Referans

Kite yon kòmantè

Adrès imel ou p ap pibliye. Jaden obligatwa yo make *