HS PLUS FJ3351A Poolmeter Instruction Manual

HS PLUS FJ3351A Poolmeter

HS PLUS FJ3351A Poolmeter

Specifications

  • Model: FJ3351A
  • Operating frequency: 433.92 MHz
  • Antenna strength: 3,324 dBm
  • Batteries: 4 × 1.5 V AAA (not included)
  • Protection rating: IP67

Features

  • Time display in 12/24-hour format
  • Measurement of pool water temperature
  • Low battery indication (external sensor)
  • Temperature display in °C or °F
  • Storage and recall of maximum and minimum temperature;
  • Temperature ranges:
    • Indoor: 0°C (32°F) to 50°C (122°F)
    • Outdoor: -40°C (-40°F) to 70°C (158°F)
  • Switchable indoor/outdoor temperature display positions
  • Wireless parameters:
    • RF transmission frequency: 433.92 MHz
    • Transmission range: up to 60 m in open spaces
  • Power supply:
    • Receiver (RX): 2 × LR03 (AAA) batteries
    • Transmitter (TX): 2 × LR03 (AAA) batteries

Product Overview

RX – Receiving Unit

  • A. External sensor temperature
  • B. Indoor temperature
  • C. Time display
  • D. Search button / switch indoor-outdoor display
  • E. Battery compartment cover
  • F. MEM button / “+”
  • G. SET button / °C / °F
  • H. Battery compartment
  • I. Stand cover
    Product Overview

TX – Underwater transmitter

  • A. Temperature sensor
  • B. Battery compartment
  • C. Main control module
  • D. Waterproof rubber ring
  • E. Cover (lens)
  • F. Locking cover
  • G. Positioning pin A
  • H. Positioning pin B
  • I. Transmitter antenna
  • J. °C / °F switch
  • K. Channel selector
  • L. LED transmission indicator
  • M. Channel indicator
  • N. Temperature display
    Product Overview

First Use

  1. Open the battery compartment of the main unit (RX).
  2. Insert 2 x AAA batteries with the correct polarity (“+” and “-“).
  3. All LCD symbols light up for 2 seconds, after which the indoor temperature is measured.
  4. The main unit automatically starts searching for the external sensor. This process takes approximately 3 minutes and is indicated by a flashing RF symbol.
  5. Open the battery compartment of the external sensor (TX) and insert 2 x AAA batteries with the correct polarity.
  6. Select the desired temperature unit (°C/°F) using switch “J”. Ensure that channel switch “K” is set to CH1.
    First Use

Important:

After opening the transmitter, do not touch any internal parts, especially the antenna. When replacing the battery compartment, ensure correct alignment of the grooves. Align the positioning pins “H” and “G”, then close the cover and the waterproof ring properly and tighten the locking cover firmly to maintain water tightness.

If pairing fails after 3 minutes, press and hold the “Search” button for 2 seconds to restart pairing mode. After successful pairing, the external sensor can be placed in the pool to measure the water temperature.

Time Setting

Press and hold the SET button for 2 seconds to enter settings mode. The selected item flashes.

  • Press the “+” button to adjust values.
  • Press the SET button to confirm and proceed to the next setting.

Setting Sequence

  1. 12/24-hour format → hour → minute
  2. After the last setting, press SET to confirm and exit.
  3. If no action is performed for 30 seconds, the device will automatically return to normal mode.

RF Transmission Procedure

  • The receiver (RX) automatically starts receiving signals after inserting the batteries.
  • The transmitter (TX) automatically transmits temperature data as soon as it is switched on.

If the receiver does not detect a signal (display “– –.–”):

  • Press and hold the Search button for 2 seconds to pair manually.
  • The RF symbol flashes while receiving the signal.

Display Of Maximum Minimum Temperature

  • The device automatically saves maximum and minimum temperature values.
  • Press the MEM button once to display the maximum value.
  • Press MEM again to display the minimum value.
  • “MAX” or “MIN” appears on the display.

To Reset Values

  • Press and hold the MEM button for 2 seconds.
  • The display briefly shows “– –.–”, indicating a reset.

Notes

  • If the temperature is below the measuring range, “LL.L” is displayed.
  • If the temperature is above the measuring range, “HH.H” is displayed.

Low Battery Indication

When the low battery symbol appears on the OUTDOOR display, replace the batteries in the external sensor.

Instructions For Recycling And Disposal

Symbol This label means that the product must not be disposed of as other household waste throughout the EU. To prevent potential damage to the environment or public health caused by uncontrolled waste disposal.

Recycle responsibly to promote the sustainable use of material resources. If you wish to return a used appliance, please use the drop-off and collection system or contact the retailer where you purchased the product. The retailer can accept the product for environmentally safe recycling.

Symbol A statement from the manufacturer that the product complies with the requirements of the applicable EU directives.

Documents / Resources

PDF thumbnailFJ3351A Poolmeter
Instruction Manual · FJ3351A, FJ3351A Poolmeter, Poolmeter

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.