1. Uvod
This manual provides comprehensive instructions for the installation, setup, operation, and maintenance of the Subzero SZ-7569T Touch Sensitive Temperature Controller. Please read this manual thoroughly before using the device to ensure proper function and safety. Keep this manual for future reference.
2. Proizvod je gotovview
The Subzero SZ-7569T is a precise, touch-sensitive temperature controller designed for various industrial and scientific applications. It features a clear digital display and intuitive touch controls for easy temperature management.

Figure 1: Subzero SZ-7569T Front Panel
The image displays the front panel of the Subzero SZ-7569T temperature controller. It features a black casing with a bright red digital LED display showing '28°C'. To the left, the 'sub-zero' brand name is visible. On the right, there are touch-sensitive buttons for 'Up' (arrow), 'Power' (circle with line), 'PRG' (program) with a 'Down' arrow, and 'SET' (set). A snowflake icon is also visible next to the temperature reading, indicating a cooling function.
3. Specifikacije
| Značajka | Detalj |
|---|---|
| Marka | Sub Zero |
| Model | SZ-7569T |
| Proizvođač | PVR Control |
| Zemlja podrijetla | Indija |
| Boja | Crna |
| Težina artikla | 210 g |
| Dimenzije proizvoda (DxŠxV) | 10 x 6 x 4 cm |
| Voltage | 220 volti (izmjenična struja) |
| Vrsta zaslona | Zaslon osjetljiv na dodir |
4. Instalacija
Proper installation is crucial for the accurate and safe operation of the temperature controller. It is recommended that installation be performed by a qualified technician.
- Prekid napajanja: Ensure all power to the installation area is disconnected before beginning any wiring.
- Montaža: Mount the controller in a secure, dry location away from direct heat sources, excessive vibration, or corrosive environments. Ensure adequate ventilation.
- Ožičenje: Connect the power supply, temperature sensor, and controlled device (e.g., heater, cooler) to the appropriate terminals on the controller. Refer to the wiring diagram provided with the product packaging for specific connections. Ensure all connections are secure and correctly polarized.
- Položaj senzora: Position the temperature sensor in the area where temperature control is required, ensuring it accurately reflects the desired measurement point and is not influenced by external factors.
- Priključak za napajanje: Nakon što je svo ožičenje dovršeno i provjereno, vratite napajanje sustava.
Warning: Incorrect wiring can lead to device malfunction, damage, or electrical hazards. Always consult the detailed wiring diagram.
5. Početno postavljanje
After installation, perform the following steps for initial setup:
- Uključivanje: Pritisnite tipku ⏻ (Power) button to turn on the device. The display will illuminate.
- Check Sensor Reading: Verify that the display shows a plausible temperature reading. If an error code appears, refer to the Troubleshooting section.
- Postavke pristupa: Pritisnite tipku SET button to enter the temperature setting mode.
- Adjust Setpoint: Koristite ⌃ (Gore) i ⌄ (Down) buttons to adjust the desired temperature setpoint.
- Confirm Setpoint: Pritisnite SET again to confirm the new setpoint and exit the setting mode.
- Program Mode (PRG): For advanced settings such as hysteresis, calibration, or alarm limits, press the PRG button. Navigate through parameters using the Up/Down arrows and confirm changes with SET. Consult the full programming guide for detailed parameter descriptions.
6. Operacija
The Subzero SZ-7569T operates automatically once the setpoint and parameters are configured. The display shows the current measured temperature.
- Prikaz temperature: The large digital display continuously shows the current temperature measured by the sensor.
- Cooling/Heating Indicator: A snowflake icon (❅) or similar indicator will illuminate when the cooling or heating output is active, depending on the configured mode.
- Adjusting Setpoint During Operation: Kratko pritisnite SET, zatim koristite ⌃ (gore) ili ⌄ (Down) to change the setpoint. Press SET opet spasiti.
- Uključivanje/isključivanje: Pritisnite i držite ⏻ (Power) button for a few seconds to turn the device off or on.
7. Održavanje
Regular maintenance ensures the longevity and accuracy of your Subzero SZ-7569T temperature controller.
- Čišćenje: Obrišite zaslon i casing s mekim, damp cloth. Do not use abrasive cleaners, solvents, or excessive moisture, as these can damage the touch panel or internal components.
- Pregled senzora: Periodically check the temperature sensor for any signs of damage or corrosion. Ensure it is securely in place.
- Veze: Occasionally inspect wiring connections to ensure they remain tight and free from corrosion.
- Provjera kalibracije: If accuracy is critical, periodically verify the controller's readings against a calibrated reference thermometer. Recalibrate if necessary, following the instructions in the programming guide.
Caution: Always disconnect power before performing any maintenance that involves opening the device or accessing internal wiring.
8. Rješavanje problema
This section addresses common issues you might encounter with the Subzero SZ-7569T.
| Problem | Mogući uzrok | Otopina |
|---|---|---|
| Zaslon je prazan | Nema napajanja; Labavo ožičenje; Kvar uređaja. | Check power connection; Verify wiring; Contact support if power is present and wiring is correct. |
| Netočno očitavanje temperature | Faulty sensor; Sensor incorrectly placed; Calibration error. | Check sensor connection and placement; Replace sensor if damaged; Perform calibration. |
| Controller not switching output | Setpoint not reached; Hysteresis setting too wide; Wiring issue; Device malfunction. | Verify setpoint and current temperature; Adjust hysteresis; Check output wiring; Contact support. |
| Gumbi ne reagiraju | Temporary software glitch; Physical damage to touch panel. | Power cycle the device; If issue persists, contact support. |
If you encounter an issue not listed here or if the suggested solutions do not resolve the problem, please contact customer support.
9. Jamstvo i podrška
The Subzero SZ-7569T Touch Sensitive Temperature Controller is covered by a standard manufacturer's warranty against defects in materials and workmanship. Please refer to the warranty card included with your product for specific terms and conditions, including the warranty period.
For technical support, service, or warranty claims, please contact PVR Control customer service. Ensure you have your product model number (SZ-7569T) and purchase details available when contacting support.
Proizvođač: PVR Control
Model: SZ-7569T