Honeywell RTY DUAL OUTPUT Series Hall Effect Rotary Position Sensors Installation Guide

RTY DUAL OUTPUT Series Hall Effect Rotary Position Sensors

Specifications:

  • Supply voltage: 10 Vdc -10 Vdc continuous
  • Supply current: 25 mA max.
  • Output signal delay: 4 ms typ.
  • Output load resistance: 10 kOhm typ.
  • EMI: radiated immunity, conducted immunity
  • Operating temp. range: Not specified
  • Storage temperature range: Not specified
  • Ingress protection: Not specified
  • Expected life: Not specified
  • Housing material: Not specified
  • Shock, Vibration, Salt fog resistance: Not specified
  • Resolution: Not specified

Product Usage Instructions:

Mounting:

Mount the sensor and/or lever using flat washers and screws as
shown in Figures 2-4.

In harsh applications, treat the screw threads with a suitable
thread locking compound.

Dual Signal Connection:

PIN 1 and PIN 4: GND (Ground)

PIN 2 and PIN 5: Vcc (Supply Voltage)

PIN 3: Output 1, PIN 6: Output 2

Caution:

Do not open or handle the device except at a static-free
workstation. The device is sensitive to electrostatic discharge
(ESD Sensitivity: Class 2).

Handling Notice:

Avoid ferrous material or magnets with over 300 Gauss within a
10 mm radius of the sensor as it may affect sensor performance.

FAQ:

Q: What should I do if the sensor readings are inaccurate?

A: Check for any ferrous material or strong magnets near the
sensor as they could be affecting its performance. Ensure proper
mounting and connections.

Q: Can the sensor be used in harsh environments?

A: Yes, the sensor can be used in harsh environments with proper
mounting and thread locking compound application.

“`

INSTALLATION INSTRUCTIONS FOR THE
HALL-EFFECT ROTARY POSITION SENSORS
RTY DUAL OUTPUT SERIES

093786-000
Issue 1

GENERAL INFORMATION
The RTY Series uses a magnetically biased, Hall-effect integrated circuit (IC) to sense rotary movement of the actuator shaft over a set operating range. Rotation of the actuator shaft changes a magnet’s position relative to the IC. The resulting flux density change is converted to a linear output.

MOUNTING INFORMATION
Mount the sensor and/or lever using flat washers and screws as shown in Figures 2-4.
In harsh applications, treat the screw threads with a suitable thread locking compound.

TABLE 1. SPECIFICATIONS CHARACTERISTIC Supply voltage Supply current
Supply current (during output to ground short)

PARAMETER 5 Vdc ±0.5 Vdc 20 mA max.
25 mA max.

Output: standard inverted2
Output signal delay
Overvoltage protection
Reverse polarity protection
Output to ground short circuit protection
Output load resistance (pull down to ground)

0.5 Vdc to 4.5 Vdc ratiometric 4.5 Vdc to 0.5 Vdc ratiometric 4 ms typ. 10 Vdc -10 Vdc
continuous
10 kOhm typ.

EMI: radiated immunity conducted immunity
EMC Operating temp. range Storage temperature range Ingress protection Expected life Media compatibility Housing material Shock1 Vibration1 Salt fog Resolution Mating connector Mechanical end stop Surge test Approvals

100 m/V per ISO11452-2 from 200 MHz to 1000 MHz 100 mA BCI per ISO11452-4 from 1 MHz to 200 MHz exceeds CE, UKCA requirements -40°C to 125°C [-40°F to 257°F] -40°C to 125°C [-40°F to 257°F] IP67 according to DIN 40050 35 M cycles heavy transportation fluids PBT plastic 50 G peak 20 G peak tested from 10 Hz to 2000 Hz concentration 5 % ±1 % for 240 hr per SAE M1455 Section 4.3.3.1 (at 5.0 Vdc, 38°C [100°F]) 12 bit AMPSEAL 16 – 6 position, P/N 776433-1 no IEC 61000-4-5, +/-1KV, CDN Method, Criteria B CE, UKCA

1 Applies to RTY sensor without lever only.

2 Removes the requirement for the customer to have to invert the logic associated with the application. This is a convenience for the customer, and in some cases, can simplify the customer’s overall solution.

HALL-EFFECT ROTARY POSITION SENSORS RTY DUAL-OUTPUT SERIES

Figure 1. Output

B

90°

A

C

Issue 1 093786-000

-45° Output
left

+45° Output
right

TABLE 2. DUAL SIGNAL

SIGNAL 1

SIGNAL 2

Pin 1

GND

Pin 4

GND

Pin 2

Vcc

Pin 5

Vcc

Pin 3

Output 1

Pin 6

Output 2

* Vcc and GND are common between channel 1 and 2

CAUTION
ELECTROSTATIC SENSITIVE DEVICES
DO NOT OPEN OR HANDLE EXCEPT AT A
STATIC FREE WORKSTATION
ESD SENSITIVITY: CLASS 2

, NOTICE
Ferrous material or more than 300 Gauss magnet within a 10 mm [0.39 in] radius of sensor may affect sensor performance.

RTY Dual-Output Installation Instructions | automation.honeywell.com/hss | 2

HALL-EFFECT ROTARY POSITION SENSORS RTY DUAL-OUTPUT SERIES

Issue 1 093786-000

TABLE 3. RTY SERIES FUNCTIONAL CHARACTERISTICS¹

CHARACTERISTIC

Sensing Angle

Linearity Accuracy Error² Error³

CHANNEL 1, OUTPUT

CHANNEL 2, OUTPUT

50° (±25°) 60° (±35°)

Clamp High 4.5

INVERSE SLOPE VARIENTS
Clamp High 4.5

Output Voltage (Vdc)

Output Voltage (Vdc)

70° (±35°)

90° (±45°) 120° (±60°)

±1.0%

±1.6%

180° (±90°)
270° (±135°) 360° (±180°)
50° (±25°)

60° (±35°)

2.5

2.5

0.5 Clamp Low

0.0

A

B

C

-25 -30 -35 -45 -60 -90 -135 -180

0

+25

0

+30

0

+35

0

+45

0

+60

0

+90

0

+135

0

+180

Actuator Position (q)

0.5 Clamp Low

0.0

A

B

C

-25

0

+25

-30

0

+30

-35

0

+35

-45

0

+45

-60

0

+60

-90

0

+90

-135

0

+135

-180

0

+180

Actuator Position (q)

POSITIVE SLOPE VARIENTS

4.5

4.5

Output Voltage (Vdc)

Output Voltage (Vdc)

70° (±35°)

2.5

2.5

90° (±45°)

120° (±60°)

±1.0%

±1.6%

180° (±90°)
270° (±135°)
360° (±180°)

0.5

0.0

A

B

C

-25

0

+25

-30

0

+30

-35

0

+35

-45

0

+45

-60

0

+60

-90

0

+90

-135

0

+135

-180

0

+180

Actuator Position (q)

0.5

0.0

A

B

C

-25

0

+25

-30

0

+30

-35

0

+35

-45

0

+45

-60

0

+60

-90

0

+90

-135

0

+135

-180

0

+180

Actuator Position (q)

1 See Figure 3 for references to A B .C 2 Linearity error is the deviation of the measured value from the best fit line and is the quotient of the measured output ratio deviation
from the best fit line at the measured temperature to the best fit line output ratio span at the measured temperature. 3 Accuracy is measured as a deviation from the index line, where the index line is defined as the line with the ideal slope and sensor output
voltage corrected at 0º position for its ideal value at 25°C ±5°C. Accuracy is valid only when the sensor output is correct at 0º position for its ideal value in the application.

RTY Dual-Output Installation Instructions | automation.honeywell.com/hss | 3

HALL-EFFECT ROTARY POSITION SENSORS RTY DUAL-OUTPUT SERIES

Issue 1 093786-000

Figure 2. Dimensional Drawings for Sensor without Lever (For reference only: mm [in])

PCD Ø 32,00 ±0,20 [Ø 1.26 ±0.007] 50° 40,4 [1.59]

43,1 [1.70] 25,6 [1.01]

2X Ø 5,35 [Ø 0.21]

5,3 [0.21]

20°
19,4 [0.76] 21,9 [0.86]

61,4 [2.42]

42,0 [1.65]

21,9 [0.86]

8,3 [0.33] 15,50 ±0,01 [0.610 ±0.003]

4,60

0 -0.05

[0.181

0.000 -0.001

]

Mounting surface

15,6 [0.61] Ø 2,0 [Ø 0.08] HI I

25,1 [0.99]

6,0 g6 [0.24]

4,10

0 -0.05

[0.161

0.000 -0.001

]

RTY Dual-Output Installation Instructions | automation.honeywell.com/hss | 4

HALL-EFFECT ROTARY POSITION SENSORS RTY DUAL-OUTPUT SERIES

Issue 1 093786-000

Figure 3. Dimensional Drawings for Sensor with Lever A (For reference only: mm [in])

40,4 [1.59]

25,6 [1.01]

2X Ø 5,35 [Ø 0.21]

42,0 [1.65]

5,0 [0.20]

21,9 [0.86]

19,4 [0.76]

61,4 [2.42]

21,9 [0.86]

10,0 [0.39] 8,3 [0.33] 22,0 [0.87] Mounting surface

42,0 [1.65] 14,0 [0.55]

15,0 [0.59] 15,7 [0.62]

Figure 4. Dimensional Drawings for Sensor with Lever B (For reference only: mm [in])

25,6 [1.01]

2X Ø 5,35 [Ø 0.21]

8,3 [0.33] 5,0 [0.20]

61,4 [2.42]

42,0 [1.65]

40,4 [1.59]

19,4 [0.76]

Mounting surface

21,9 [0.86]

21,9 [0.86]

14,0 [0.55]

15,7 [0.62]

50,0 [1.97] 15,0 [0.59]

RTY Dual-Output Installation Instructions | automation.honeywell.com/hss | 5

For more information Honeywell Sensing Solutions services its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing, or the nearest Authorized Distributor, visit automation.honeywell. com/hss or call:

USA/Canada Latin America Europe Japan Singapore
Greater China

+302 613 4491 +1 305 805 8188 +44 1344 238258 +81 (0) 3-6730-7152 +65 6355 2828
+86 4006396841

WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgment or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While Honeywell may provide information or engineering support for its products through Honeywell personnel, literature and website, it is the buyer’s sole responsibility to determine the suitability of the Honeywell product(s) for the buyer’s requirements.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use.

m WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
m WARNING
MISUSE OF DOCUMENTATION
· The information presented in this product sheet is for reference only. Do not use this document as a product installation guide.
· Complete installation, operation, and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.

Honeywell Sensing Solutions 830 East Arapaho Road Richardson, TX 75081 www.honeywell.com

093786-000 -1-EN | 1 | 05/25 © 2025 Honeywell International Inc.