Honeywell N100 Series Non-Programmable
FocusPRO N100 Series Nonprogrammable Thermostat
TH1110U4000, TH1320U4002
Scan for the full Installation Manual
info.honeywellhome.com/focuspro-n100-im
NOTE: For Heat Pump systems do NOT attach a wire to the W terminal of the UWP™ Mounting System.
Installer Setup (ISU) Settings
On initial setup, the thermostat will enter the ISU menu. If entering the ISU menu after initial setup, follow the steps below:
- Press and hold the bottom left button and Up arrow
button for 5 seconds to access the INSTALLER SETUP (ISU).
- The ISU number is on the left. The ISU setting is on the right.
When an ISU number is displayed, pressor
to change the setting.
- After choosing the correct setting for an ISU, press NEXT to advance to the next ISU setting.
- To finish setup, press the SAVE & EXIT button.
#ISU | ISU Name | ISU Options (default in bold) |
1050 | Temperature Scale | F = Fahrenheit C = Celsius |
1060 | Outdoor Sensor (TH1320U4002 Only) | 0 = None
1 = Wired Outdoor Sensor |
2000 | Heating System Type | 1 = Conventional Forced Air Heat
2 = Heat Pump 3 = Radiant Heat 5 = None (Cool Only) |
2010 | Heating Equipment Type | Conventional Forced Air Heat:
1 = Standard Efficiency Gas Forced Air 2 = High Efficiency Gas Forced Air 3 = Oil Forced Air 4 = Electric Forced Air 5 = Hot Water Fan Coil Heat pump: 7 = Air to Air Heat Pump 8 = Geothermal Heat Pump Radiant Heat: 9 = Hot Water Radiant Heat 12 = Steam |
2060 | Reversing Valve O/B | O = O (O/0B in Cool)
1 = B (O/0B in Heat) |
2070 | Compressor Stages | 0, 1, 2 (2 for TH1320U4002 Only) |
2071 | Heat Stages / Backup Heat Stages | Heat Stages: 1, 2
Backup Heat Stages (TH1320U4002 Only): 0, 1 |
2110 | Fan Control in Heat (Shown if 2010 = 4 or 5) | 1 = Equipment Controls fan
2 = Thermostat Controls Fan |
2175 | Aux / E Terminal Control | 0 = Drive both Aux & E together
1 = Aux and E independent |
2180 | Backup Heat Source (Heat Pump Only) (TH1320U4002 Only) | 31 = Electric Forced Air
32 = Standard Efficiency Gas Forced Air 33 = High Efficiency Gas Forced Air 34 = Oil Forced Air, Hot Water Fan Coil 35 = Hot Water Radiant Heat 36 = Other |
2185 | Emergency Heat Source (TH1320U4002 Only) | |
3000 | System Changeover | 0 = Manual
1 = Automatic |
3015 | Auto Changeover Differential | 0°F to 5°F
0.0°C to 2.5°C |
3020 | Finish With High Cool Stage | 0 = No
1 = Yes |
3021 | Finish With High Heat Stage | 0 = No
1 = Yes |
3090 | Backup Heat Droop (For heat pump with aux heat stage. 0 only for electric) | 0 = Comfort
2 °F to 15 °F in 1 °F increments) 1.0 °C to 7.5 °C (in 0.5 °C increment). |
3110 | Upstage Time for Backup Heat
(If 3090 = 0 and 2180 = 31, 3110 only has settings 0-3) |
0 = Off 8 = 4 hours
1 = 30 minutes 9 = 5 hours 2 = 45 minutes 10 = 6 hours 3 = 60 minutes 11 = 8 hours 4 = 75 minutes 12 = 10 hours 5 = 90 minutes 13 = 12 hours 6 = 2 hours 14 = 14 hours 7 = 3 hours 15 = 16 hours |
3120 | Compressor Lockout. Wired outdoor sensor is needed. | 0 = Off 25 = 25°F (-4°C)
1 = -15°F (-26°C) 30 = 30°F (-1°C) 2 = -10°F (-23.5°C) 35 = 35°F (1.5°C) 3 = -5°F (-20.5°C) 40 = 40°F (4.5°C) 4 = 0°F (-18°C) 45 = 45°F (7°C) 5 = 5°F (-15°C) 50 = 50°F (10°C) 10 = 10°F (-12°C) 55 = 55°F (13°C) 15 = 15°F (-9.5°C) 60 = 60°F (15.5°C) 20 = 20°F (-6.5°C) 65 = 65°F (18.5°C) (Setting 65 not for 3120. 1-5 not for 3121) |
3121 | Outdoor Lockout Backup Heat.
Wired outdoor sensor is needed. |
|
3125 | Lockout Fan after a Cool Call | [0] = Off [1] 5 min to [24] 120 min (in 5 minutes increments) |
3140 | Compressor Cycle Rate (Stage 1) | 1-6 |
3141 | Compressor Cycle Rate (Stage 2) | 1-6 (TH1320U4002 only) |
3150 | Heating Cycle Rate (Stage 1) | 1-12 |
3151 | Heating Cycle Rate (Stage 2) | 1-12 (TH1320U4002 only) |
3160 | Heating Cycle Rate Auxiliary Heat | 1-12 (TH1320U4002 only) |
3165 | Heating Cycle Rate Emergency Heat | 1-12 (TH1320U4002 only) |
info.honeywellhome.com/focuspro-n100-im
NOTE:
- The complete list of ISUs can be found in the online Installation Manual.
- Device input power rating: 24V, 60Hz, 1.1VA.
- Device contact ratings of up to 1A, inductive.
CAUTION: ELECTRICAL HAZARD
- Can cause electrical shock or equipment damage.
- Disconnect power before beginning installation.
CAUTION: EQUIPMENT DAMAGE HAZARD
- Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly
CAUTION: MERCURY NOTICE
- If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local wast management authority for instructions regarding recycling and proper disposal.
CAUTION: ELECTRONIC WASTE NOTICE
- The product and batteries should not be disposed of with other household waste. Check for the nearest authorized collection center or authorized recyclers. The correct disposal of end-of-life equipment will help prevent negative consequences for the environment and human health.
FCC statement available at:
https://customer.resideo.com/en-US/support/residential/codes-and-standards/FCC15105/Pages/default.aspx
Customer Assistance
For assistance with this product, please visit customer.resideo.com
Or call Resideo Customer Care toll-free at 1-800-633-3991
Thermostat
Documents / Resources
![]() |
Honeywell N100 Series Non Programmable Thermostat [pdf] Installation Guide N100 Series, N100 Series Non Programmable Thermostat, Non Programmable Thermostat, Programmable Thermostat, Thermostat |
![]() |
Honeywell N100 Series Non Programmable Thermostat [pdf] Installation Guide TH1110U4000, TH1320U4002, N100 Series Non Programmable Thermostat, N100 Series, Non Programmable Thermostat, Programmable Thermostat |