Cov khoom lag luam
- Order code Kev piav qhia
- zc-ss-6 swb-blk Ntse hloov nrog 6 nyees khawm kom haum 84 hli phab ntsa mount, dub
- zc-ss-6 swb-wht Ntse hloov nrog 6 nyees khawm kom haum 84 hli phab ntsa mount, dawb
- zc-ss-6sw-eu-blk Ntse hloov nrog 6 nyees khawm kom haum 84 hli phab ntsa mount, dub
- zc-ss-6sw-eu-wht Ntse hloov nrog 6 nyees khawm kom haum 84 hli phab ntsa mount, dawb
Specifications
- Kev muab khoom 220-240 V
- Cov khoom siv tam sim no 4 mA
- Tswj qhov system IEC 62386-104 dhau Thread® / DALI-2
- Xov tooj cua txhawb nqa IEEE 802.15.4
- Zaus band 2.4 GHz ceev
- Max radio tx power + 8 dBm
- DALI kab tam sim no 2 mA
- Kev xaim 1-4 hli 2
- Sawb 8-10 hli
- Ua haujlwm kub 0 rau 55 ° C
- Khoom siv PC, UV stabilised, toughened glass, aluminium
- Ingress tiv thaiv IP20
Cov ntaub ntawv kev nyab xeeb
- Cov khoom no tsuas yog yuav tsum tau teeb tsa los ntawm tus kws kho hluav taws xob muaj ntawv tso cai.
- Ua ntej pib installation, tua thiab cais cov khoom siv hluav taws xob.
- There are no user-serviceable parts; attempting to service any part of the product will void the warranty
- DALI is not SELV and, as such, should be treated as LV.
- As the installer, it is your responsibility to ensure you comply with all relevant building and safety codes. Refer to application standards for the relevant rules.
- Isolate the electrical supply before removing the faceplate. The circuit board is NOT isolated.
Qhov ntev
Qhov Loj (mm)
System dhau lawmview
System dhau lawmview: hom
- 104 hom yog qhib tom qab lub cuab yeej tau ntxiv rau 104 daim ntawv thov xws li zc-iot-fc.

- 104 + 101 Choj hom yog qhib tom qab lub cuab yeej tau ntxiv rau 104 maub los thiab 101 fais fab mov tau txuas nrog DALI terminals.

- 101 hom yog qhib tom qab 101 fais fab mov tau txuas nrog DALI davhlau ya nyob twg thiab cov cuab yeej tsis tau ntxiv rau 104 daim ntawv thov tswj.

Kev teeb tsa
Tshem cov khoom tawm ntawm lub thawv thiab tshuaj xyuas nws kom muaj kev puas tsuaj. Yog tias koj ntseeg tias cov khoom puas los yog tsis zoo, tsis txhob nruab cov khoom. Thov ntim nws rov qab rau hauv nws lub thawv thiab xa rov qab mus rau qhov chaw yuav khoom hloov.
Yog hais tias cov khoom txaus siab, mus rau lub installation:
- Xyuas kom meej tias cov lus ceeb toom kev nyab xeeb raug ua raws.
- Optional: Connect the two DALI terminals to the DALI line ensuring wiring regulations are followed. DALI is not polarised. DALI is not SELV and as such must be treated as LV. Do not connect DALI to any mains voltages.
- Remove the front plate by inserting a screwdriver (min. 5.5pt) into receptacle at the bottom of the frame. Twist left, twist right, to release cover, do not lever.
- Cut out the hole, insert wallbox if applicable.
- Ntxig muab screws rau hauv thav duab thiab txuas rau pre-mounted wallbox / c-clip.
- Not applicable to eu versions. Latch cover on top of frame to clip base back into frame, attached on the wall.

Cov kab kos duab
Cov lus qhia configuration

Ensure each terminal is lined up with the correct marking on the product label
Kev teeb tsa
- By default, the device is configured with six control device instances with LED indicators. Actual function is dependant on the configuration of DALI-2 application controllers connected to the DALI line, or the Wireless application controller.
- By default,t the device will configure its mode of operation depending on what has been commissioned.
ECD kev ua haujlwm hom
- 128 (0x80) Bridge mode (default): The Device acts as a bridge between the Thread 104 interface and DALI devices connected via the 101 interface
- 129 (0x81) Beacon mode: The Device broadcasts Bluetooth beacons and communicates via the 104 interface if the Thread network is commissioned; otherwise via the 101 interface. For more information on how to configure Beacons, visit support. zencontrol.com
- 130 (0x82) Bridge disabled: The Device communicates via both 104+101 interface; however, bridge mode is disabled (i.e., Devices connected on the 101 interface will not be available on the Thread 104 system)
Xov xwm ntxiv
Daim ntawv ceeb toom
For more information on compliant software, see our webqhov chaw, zencontrol.com
FAQs
- Q: Can I service any part of the product myself?
- A: No, there are no user-serviceable parts. Attempting to service any part will void the warranty.
- Q: What is the recommended installation procedure?
- A: The product should only be installed by a licensed electrician after turning off and isolating the electrical supply.
- Q: How do I enable different modes on the system?
- A: Different modes are enabled based on the connections to a DALI terminal and specific application controllers as outlined in the manual.