Antari FT-70 Fire Training Fog Machine

User Manual - English

Introduction

Please read this user manual thoroughly before operating the machine and keep it accessible for future reference. The manual provides instructions on safe installation and operation, and explains all labels printed on the machine. If you encounter any problems, please contact your local Antari dealer for immediate assistance.

Safety Information

[DANGER] If the danger is not avoided, it will cause death or serious injury.

[WARNING] If the warning is not heeded, it can cause death or serious injury.

[CAUTION] If the precaution is not taken, it may cause minor or moderate injury.

DANGER

WARNING

CAUTION

Before operating the machine, please read all warning labels on the machine, description as below:

Top Cover Warning: Hot Nozzle & Surface, Do NOT Touch

Back Cover Warning: ONLY USE MANUFACTURER-DESIGNATED FLUID. BITTE VERWENDEN SIE NUR DIE VOM HERSTELLER ANGEGEBENE FLÜSSIGKEIT. MERCI DE N’UTILISER QUE LE LIQUIDE RECOMMANDE PAR LE FABRICANT.

Package Contents & Inspection

Package Contents

Immediately upon receiving the machine, carefully unpack the carton, check the content to ensure it is the correct model and all parts are included. If any part appears to be damaged or missing during transportation, please contact your local dealer and return in original package for inspection.

Optional Accessories

Item CodeDescription
N/AN/A

Machine Details

Diagram showing machine parts:

01. Nozzle, 02. Handle, 03. Fluid Tank, 04. Fluid Tube, 05. Rotary Knob, 06. XLR 5-Pin Connector, 07. 2 in 1 Power & Breaker Switch, 08. IEC Connector (Power), 09. Fluid Level Indicator, 10. W-2 Wireless Receiver

Technical Label Information

Please read the technical label information on the back of the machine before operating it.

Label details:

1. Model Name: XXXX, 2. Input Voltage: XXXX Vac, 3. Frequency: 50/60Hz, 4. Rated Power: XXXW, 5. Breaker/Fuse: XXA 250V, 6. QR CODE for User Manual, 7. Serial No.: XXXXXMMYYXXXXX

Fog Fluid

[CAUTION] Always turn off the power before filling the fluid tank. Do not add flammable liquid to the fluid tank. If fluid gets inside the machine, please contact your local Antari dealer for assistance.

Setting and Manual Operation

[WARNING] Machine falling off might cause serious injury; please make sure it is secure and firm on the overhead.

  1. Place the machine on a flat, level, hard, and well-ventilated surface area and reserve at least 50 cm open space around the machine, and make sure there is no flammable gas or material nearby.
  2. Fill the fluid tank with Antari approved fog fluid, and make sure the tube is not twisted.
  3. Connect the machine to the power outlet. Please read the technical label on the back of the machine and make sure the power outlet corresponds to the rated voltage for the machine.
  4. Turn on the machine. The warm-up process takes approximately 7 minutes, and the indicator light will flash "Green". Once the machine has reached operating temperature, the indicator light will flash constant "Green". The machine is now ready for operation.
  5. Press the rotary knob to start fogging and turn right to adjust volume; press the rotary knob again to stop fogging.
  6. To turn off the machine, please make sure the machine is not operating, then turn off the power. If you will not use the machine for a long period of time, please remove the power cord.

Control Settings

The FT-70 Fire Training Fog Machine can be operated in the following modes. The machine can only accept 1 type of signal at a time:

Machine Status

StatusLED Indicator LightBuzzer
Heating Upflash once every 2 sec.nil
Readypermanentnil
Fogpermanentnil
Voltage ErrornilPermanent
Thermal Faultflash twice every 3 sec.Beep Twice Every 3 Sec.
Thermal Reverseflash three times every 3 sec.Beep Three Times Every 3 Sec.
Heater Faultflash four times every 3 sec.nil
Overheatflash once every 0.4 sec.nil

WTR-120 Wireless Remote (Standard)

The WTR-120 Wireless Remote is a standard accessory for the FT-70 Fire Training Fog Machine. It includes a W-3 wireless transmitter and a W-2 wireless receiver (already installed on the machine), and is ready to use. If you encounter any problem, please contact your local Antari dealer for assistance.

W-3 Wireless Transmitter & W-2 Receiver

The W-3 wireless transmitter has 4 buttons, each functioning as follows:

ButtonFunction
[A]Start Fogging
[B]Stop Fogging
[C]Increase Fog Output
[D]Decrease Fog Output

Diagram of W-3 Wireless Transmitter and W-2 Wireless Receiver.

Pairing

Each receiver can pair up to 5 transmitters. Please follow the steps below to pair the transmitter:

  1. Press and hold the rotary knob and turn on the power of the machine until the indicator light flashes "Red" and "Green" alternately.
  2. When the indicator flashes "Red" and "Green" alternately, press any button on the W-3 remote to pair.
  3. Simply repeat the above steps to pair more transmitters.

Service and Maintenance

[DANGER] Disconnect the power cord before starting maintenance operation!

Breaker Reset (2 in 1 Power Switch)

The 2 in 1 power switch combines power and breaker functions. Please follow these steps to reset the breaker:

  1. Please switch the power to the OFF position.
  2. Wait 60 seconds.
  3. Flip the switch back on.

**If the breaker (switch) still trips off after reset, please contact your local Antari dealer for assistance.

Breaker Specification: 120V 15A, 230V 9A

Technical Specifications

FT-70
Input VoltageUS Model: AC 100-120V, 50/60Hz 8.5A
EU Model: AC 220-240V, 50/60Hz 4.5A
Rated Power1000W
Warming-up Time7 minutes (approx.)
Fluid Consumption60 ml/min (100% output)
Fluid Tank Capacity1.7 Liters (0.45 Gallon)
Compatible FluidFLP
Ambient Temp. Range0°C ~ 40°C (32°F – 104°F)
Control MethodsManual, Wireless
InterfaceXLR 5-Pin Connector (Remote), IEC Connector (Power)
DMX ChannelsN/A
Included AccessoriesW-3 Wireless Transmitter
Optional AccessoriesN/A
DimensionL 417 W 178 H 273 mm (L 16.42 W 7.01 H 10.75 inch)
Weight7.0 kg (15.43 lbs.)

Warranty Disclaimer

Antari guarantees its merchandise to be free from defects in material and workmanship for a period of one year. Antari's obligation and liability under this warranty shall be restricted to repair or replacement at their factory or local authorized dealer. Antari assumes no liability for products that are improperly used or used for any purpose other than that for which they are specially designed. This warranty shall not apply to any merchandise which has been repaired, altered, or assembled outside Antari's factory in any way that, in their judgment, affects its performance, nor which has been subjected to misuse, negligence, or accident, nor to any merchandise operated contrary to Antari's printed instructions. Antari will not allow or be liable for any loss or any damages of any kind in connection with the use, sale, or repair of any merchandise purchased from them.

Machine Dimension

Diagram showing machine dimensions:

Front view: Width 178 mm, Height 273 mm. Side view: Length 417 mm, Height 273 mm, Depth 155 mm.

Appendix I – Grounding Instruction

This appliance must be grounded. In the event of malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

[DANGER] Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment-grounding conductor. If repair or replacement of the cord or plug is necessary, do not connect the equipment-grounding conductor to a live terminal. Check with a qualified electrician or serviceman if the grounding instructions are not completely understood, or if in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

This appliance is for use on a nominal 120V circuit, and has a grounding plug that looks like the plug illustrated in sketch A in Figure. A temporary adaptor, which looks like the adaptor illustrated in sketches B and C, may be used to connect this plug to a 2-pole receptacle as shown in sketch B if a properly grounded outlet is not available. The temporary adaptor should be used only until a properly grounded outlet can be installed by a qualified electrician. The green colored rigid ear, lug, and the like, extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adaptor is used, it must be held in place by the metal screw.

Diagram illustrating grounding plug (A), adapter (B, C), and grounded outlet box cover (D).

Models: FT-70, FT-70 Fire Training Fog Machine, FT-70, Fire Training Fog Machine, Training Fog Machine, Fog Machine, Machine

File Info : application/pdf, 16 Pages, 1.21MB

PDF preview unavailable. Download the PDF instead.

?wpdmdl=9720&refresh=6864d67ed8b981751438974 Microsoft Word 2016 Microsoft Word 2016

Related Documents

Preview Antari FT-200 Fire Training Fog Machine User Manual
Comprehensive user manual for the Antari FT-200 Fire Training Fog Machine. This guide covers essential safety information, unpacking and inspection, product overview, setup instructions, detailed operation modes (timer, volume, DMX, wireless), control panel functions, menu settings, fluid recommendations, maintenance procedures, breaker reset, and technical specifications.
Preview Antari FT-100 Fire Training Fog Machine User Manual
Comprehensive user manual for the Antari FT-100 Fire Training Fog Machine, detailing setup, operation, safety precautions, maintenance, and technical specifications. Essential for fire training simulations.
Preview Antari W-101 Bubble Machine User Manual - Setup, Operation, and Specifications
Comprehensive user manual for the Antari W-101 Bubble Machine, covering setup, operation, safety guidelines, wireless remote control, technical specifications, and warranty information.
Preview Antari FT-20X Fire Training Fog Machine User Manual
User manual for the Antari FT-20X Fire Training Fog Machine, providing detailed instructions on safety, setup, operation, DMX control, remote operation, maintenance, and technical specifications.
Preview Antari MB-1 Mobile Fog Machine User Manual and Guide
Comprehensive user manual for the Antari MB-1 Mobile Fog Machine, covering setup, operation, safety, maintenance, and technical specifications. Learn how to use your MB-1 fogger effectively.
Preview Antari WTR-20 Wireless Remote: Transmitter & Receiver Installation and Operation
Guide to installing and using the Antari WTR-20 Wireless Remote, including transmitter functions and receiver pairing instructions for Z-1500 III and Z-3000 III Fog Machines.
Preview Antari DNG-250 Low Fog Generator User Manual | Operation & Maintenance Guide
Comprehensive user manual for the Antari DNG-250 Low Fog Generator. Learn about setup, operation, safety, maintenance, technical specifications, and troubleshooting. Get detailed instructions for this professional fog machine.
Preview Antari Z-390 Fazer User Manual
Comprehensive user manual for the Antari Z-390 Fazer fog machine, covering safety information, setup, operation, maintenance, and technical specifications.