Introduction
Please read this user manual thoroughly before operating the machine and keep it accessible for future reference. The manual provides instructions on safe installation and operation, and explains all labels printed on the machine. If you encounter any problems, please contact your local Antari dealer for immediate assistance.
Safety Information
[DANGER] If the danger is not avoided, it will cause death or serious injury.
[WARNING] If the warning is not heeded, it can cause death or serious injury.
[CAUTION] If the precaution is not taken, it may cause minor or moderate injury.
DANGER
- Must connect the machine to the correct rated voltage or it might lead to an electrical shock or a burn and may cause serious consequences.
- Must connect the machine to a protected circuit and ensure it is properly grounded to avoid the risk of electrocution. For grounding instruction, please refer to Appendix I on page 13.
- Do not operate the machine with a bundled power cord, it could lead to a fire hazard.
- When operating the machine, do not point at people, animals, or fire.
WARNING
- The machine's nozzle is extremely hot; please keep at least 50cm distance from the nozzle when the machine is running.
- Please operate the machine on a flat, level, hard, and well-ventilated surface area, reserve at least 50cm space around the machine, and make sure there is no flammable gas or material nearby.
- Do not disassemble, repair, or modify the machine, as it may cause damages, malfunction, risk of electrical shock, or result in fire.
- The machine can only be operated by adults or professionals. It is not intended for use by persons with reduced physical sensory, mental capabilities, or lack of experience and knowledge, including children.
- Do not leave the machine running unattended; make sure all power is off when leaving.
- Children should be supervised to ensure that they do not play with the machine.
- Do not use the machine upside down or tilt it, as it might cause damages or malfunction.
- Please store the fluid inside in a well-ventilated area without direct sunlight and keep out of reach of children.
- In case of eye contact or accidental swallowing of the fluid, please seek medical attention immediately.
CAUTION
- Keep the machine dry at all time. The machine is not waterproof; do not expose the machine to water, rain, or moisture.
- Please make sure the power outlet is not damaged or loose before plugging in the power cord.
- If the power cord is damaged, it must be replaced by Antari or its local dealers, otherwise the warranty will be void.
- Before operating the machine, ensure the fluid is filled in the fluid tank to avoid the pump idling, which could lead to overheating or malfunction.
- Before transporting the machine, please make sure the fluid is drained and the tank is empty. (Recommend using the original package)
- The machine is for indoor use only.
- Do not operate the machine in any area with unstable voltage.
- If you experience strange sound or malfunction, turn off the power and unplug the power cord immediately and contact your local Antari dealer for assistance.
- Do not contact any moving parts.
- Only use accessories recommended or sold by Antari.
- Please make sure the power is off when not using the machine and unplug the power cord if not intended for use for a long period of time.
- To disconnect, turn all controls to the off position, then remove the plug from the outlet.
- Do not unplug by pulling on the cord. To unplug, grasp the plug, not the cord.
- Unplug from outlet before servicing or cleaning.
- Do not operate the machine with a damaged cord or plug, or after the machine malfunctions or is dropped or damaged in any manner. Return the machine to the nearest authorized service facility for examination, repair, or electrical or mechanical adjustment.
- To ensure the lifespan of the machine, please only use the fluid manufactured by Antari. Do not use other fluid or additives, otherwise it may clog the heater and cause malfunction.
Before operating the machine, please read all warning labels on the machine, description as below:
Top Cover Warning: Hot Nozzle & Surface, Do NOT Touch
Back Cover Warning: ONLY USE MANUFACTURER-DESIGNATED FLUID. BITTE VERWENDEN SIE NUR DIE VOM HERSTELLER ANGEGEBENE FLÜSSIGKEIT. MERCI DE N’UTILISER QUE LE LIQUIDE RECOMMANDE PAR LE FABRICANT.
Package Contents & Inspection
Package Contents
Immediately upon receiving the machine, carefully unpack the carton, check the content to ensure it is the correct model and all parts are included. If any part appears to be damaged or missing during transportation, please contact your local dealer and return in original package for inspection.
- 1 x FT-70 Fire Training Fog Machine
- 1 x 1.7 Liter Fluid Tank
- 1 x W-3 Wireless Remote
- 1 x IEC Power Cable
- 1 x Quick Start Guide
Optional Accessories
Item Code | Description |
---|---|
N/A | N/A |
Machine Details
Diagram showing machine parts:
01. Nozzle, 02. Handle, 03. Fluid Tank, 04. Fluid Tube, 05. Rotary Knob, 06. XLR 5-Pin Connector, 07. 2 in 1 Power & Breaker Switch, 08. IEC Connector (Power), 09. Fluid Level Indicator, 10. W-2 Wireless Receiver
Technical Label Information
Please read the technical label information on the back of the machine before operating it.
Label details:
1. Model Name: XXXX, 2. Input Voltage: XXXX Vac, 3. Frequency: 50/60Hz, 4. Rated Power: XXXW, 5. Breaker/Fuse: XXA 250V, 6. QR CODE for User Manual, 7. Serial No.: XXXXXMMYYXXXXX
Fog Fluid
[CAUTION] Always turn off the power before filling the fluid tank. Do not add flammable liquid to the fluid tank. If fluid gets inside the machine, please contact your local Antari dealer for assistance.
- Only the fog fluid manufactured by Antari can be used; do not mix or dilute the fog fluid. Due to improper storage or using other fluid, it might clog the heater and cause malfunction.
- The machine is tested and calibrated with the specific fog fluid to get the best performance.
- Please empty the fluid in the tank before switching to another fluid to avoid mixing.
- Only the essence manufactured by Antari can be used, and add according to the ratio recommended by Antari (Recommended ratio is 1:1000). If using other essence or a different ratio, it might clog the heater and cause malfunction.
- The warranty on your fog machine will be void if you use fog fluid not manufactured by Antari.
Setting and Manual Operation
[WARNING] Machine falling off might cause serious injury; please make sure it is secure and firm on the overhead.
- Place the machine on a flat, level, hard, and well-ventilated surface area and reserve at least 50 cm open space around the machine, and make sure there is no flammable gas or material nearby.
- Fill the fluid tank with Antari approved fog fluid, and make sure the tube is not twisted.
- Connect the machine to the power outlet. Please read the technical label on the back of the machine and make sure the power outlet corresponds to the rated voltage for the machine.
- Turn on the machine. The warm-up process takes approximately 7 minutes, and the indicator light will flash "Green". Once the machine has reached operating temperature, the indicator light will flash constant "Green". The machine is now ready for operation.
- Press the rotary knob to start fogging and turn right to adjust volume; press the rotary knob again to stop fogging.
- To turn off the machine, please make sure the machine is not operating, then turn off the power. If you will not use the machine for a long period of time, please remove the power cord.
Control Settings
The FT-70 Fire Training Fog Machine can be operated in the following modes. The machine can only accept 1 type of signal at a time:
- Manual
- Wireless
Machine Status
Status | LED Indicator Light | Buzzer |
---|---|---|
Heating Up | flash once every 2 sec. | nil |
Ready | permanent | nil |
Fog | permanent | nil |
Voltage Error | nil | Permanent |
Thermal Fault | flash twice every 3 sec. | Beep Twice Every 3 Sec. |
Thermal Reverse | flash three times every 3 sec. | Beep Three Times Every 3 Sec. |
Heater Fault | flash four times every 3 sec. | nil |
Overheat | flash once every 0.4 sec. | nil |
WTR-120 Wireless Remote (Standard)
The WTR-120 Wireless Remote is a standard accessory for the FT-70 Fire Training Fog Machine. It includes a W-3 wireless transmitter and a W-2 wireless receiver (already installed on the machine), and is ready to use. If you encounter any problem, please contact your local Antari dealer for assistance.
W-3 Wireless Transmitter & W-2 Receiver
- Battery: 27A 12V
- Effective Range: The effective range is approximately 50m, depending on actual conditions; it may vary. If the effective range is significantly shorter, please change the battery.
The W-3 wireless transmitter has 4 buttons, each functioning as follows:
Button | Function |
---|---|
[A] | Start Fogging |
[B] | Stop Fogging |
[C] | Increase Fog Output |
[D] | Decrease Fog Output |
Diagram of W-3 Wireless Transmitter and W-2 Wireless Receiver.
Pairing
Each receiver can pair up to 5 transmitters. Please follow the steps below to pair the transmitter:
- Press and hold the rotary knob and turn on the power of the machine until the indicator light flashes "Red" and "Green" alternately.
- When the indicator flashes "Red" and "Green" alternately, press any button on the W-3 remote to pair.
- Simply repeat the above steps to pair more transmitters.
Service and Maintenance
[DANGER] Disconnect the power cord before starting maintenance operation!
- Always keep the machine clean and dry.
- Use an air compressor, vacuum, or a soft brush to remove dust from the machine.
- The casing can be cleaned with a slightly damp cloth.
- Before storing the machine, please ensure the machine has completely cooled down to avoid moisture inside causing malfunction.
- It is recommended to run the machine at least once a month to maintain its best performance and output condition.
- Excessive dust and build-up liquid residue will reduce performance and cause overheating.
Breaker Reset (2 in 1 Power Switch)
The 2 in 1 power switch combines power and breaker functions. Please follow these steps to reset the breaker:
- Please switch the power to the OFF position.
- Wait 60 seconds.
- Flip the switch back on.
**If the breaker (switch) still trips off after reset, please contact your local Antari dealer for assistance.
Breaker Specification: 120V 15A, 230V 9A
Technical Specifications
FT-70 | |
---|---|
Input Voltage | US Model: AC 100-120V, 50/60Hz 8.5A EU Model: AC 220-240V, 50/60Hz 4.5A |
Rated Power | 1000W |
Warming-up Time | 7 minutes (approx.) |
Fluid Consumption | 60 ml/min (100% output) |
Fluid Tank Capacity | 1.7 Liters (0.45 Gallon) |
Compatible Fluid | FLP |
Ambient Temp. Range | 0°C ~ 40°C (32°F – 104°F) |
Control Methods | Manual, Wireless |
Interface | XLR 5-Pin Connector (Remote), IEC Connector (Power) |
DMX Channels | N/A |
Included Accessories | W-3 Wireless Transmitter |
Optional Accessories | N/A |
Dimension | L 417 W 178 H 273 mm (L 16.42 W 7.01 H 10.75 inch) |
Weight | 7.0 kg (15.43 lbs.) |
Warranty Disclaimer
Antari guarantees its merchandise to be free from defects in material and workmanship for a period of one year. Antari's obligation and liability under this warranty shall be restricted to repair or replacement at their factory or local authorized dealer. Antari assumes no liability for products that are improperly used or used for any purpose other than that for which they are specially designed. This warranty shall not apply to any merchandise which has been repaired, altered, or assembled outside Antari's factory in any way that, in their judgment, affects its performance, nor which has been subjected to misuse, negligence, or accident, nor to any merchandise operated contrary to Antari's printed instructions. Antari will not allow or be liable for any loss or any damages of any kind in connection with the use, sale, or repair of any merchandise purchased from them.
Machine Dimension
Diagram showing machine dimensions:
Front view: Width 178 mm, Height 273 mm. Side view: Length 417 mm, Height 273 mm, Depth 155 mm.
Appendix I – Grounding Instruction
This appliance must be grounded. In the event of malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
[DANGER] Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment-grounding conductor. If repair or replacement of the cord or plug is necessary, do not connect the equipment-grounding conductor to a live terminal. Check with a qualified electrician or serviceman if the grounding instructions are not completely understood, or if in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
This appliance is for use on a nominal 120V circuit, and has a grounding plug that looks like the plug illustrated in sketch A in Figure. A temporary adaptor, which looks like the adaptor illustrated in sketches B and C, may be used to connect this plug to a 2-pole receptacle as shown in sketch B if a properly grounded outlet is not available. The temporary adaptor should be used only until a properly grounded outlet can be installed by a qualified electrician. The green colored rigid ear, lug, and the like, extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adaptor is used, it must be held in place by the metal screw.
Diagram illustrating grounding plug (A), adapter (B, C), and grounded outlet box cover (D).
File Info : application/pdf, 16 Pages, 1.21MB
DocumentDocumentRelated Documents
![]() |
Antari FT-200 Fire Training Fog Machine User Manual Comprehensive user manual for the Antari FT-200 Fire Training Fog Machine. This guide covers essential safety information, unpacking and inspection, product overview, setup instructions, detailed operation modes (timer, volume, DMX, wireless), control panel functions, menu settings, fluid recommendations, maintenance procedures, breaker reset, and technical specifications. |
![]() |
Antari FT-100 Fire Training Fog Machine User Manual Comprehensive user manual for the Antari FT-100 Fire Training Fog Machine, detailing setup, operation, safety precautions, maintenance, and technical specifications. Essential for fire training simulations. |
![]() |
Antari W-101 Bubble Machine User Manual - Setup, Operation, and Specifications Comprehensive user manual for the Antari W-101 Bubble Machine, covering setup, operation, safety guidelines, wireless remote control, technical specifications, and warranty information. |
![]() |
Antari FT-20X Fire Training Fog Machine User Manual User manual for the Antari FT-20X Fire Training Fog Machine, providing detailed instructions on safety, setup, operation, DMX control, remote operation, maintenance, and technical specifications. |
![]() |
Antari MB-1 Mobile Fog Machine User Manual and Guide Comprehensive user manual for the Antari MB-1 Mobile Fog Machine, covering setup, operation, safety, maintenance, and technical specifications. Learn how to use your MB-1 fogger effectively. |
![]() |
Antari WTR-20 Wireless Remote: Transmitter & Receiver Installation and Operation Guide to installing and using the Antari WTR-20 Wireless Remote, including transmitter functions and receiver pairing instructions for Z-1500 III and Z-3000 III Fog Machines. |
![]() |
Antari DNG-250 Low Fog Generator User Manual | Operation & Maintenance Guide Comprehensive user manual for the Antari DNG-250 Low Fog Generator. Learn about setup, operation, safety, maintenance, technical specifications, and troubleshooting. Get detailed instructions for this professional fog machine. |
![]() |
Antari Z-390 Fazer User Manual Comprehensive user manual for the Antari Z-390 Fazer fog machine, covering safety information, setup, operation, maintenance, and technical specifications. |