Danfoss AMV 110 NL, AMV 120 NL Operating Guide

This document provides essential information for the safe and effective operation of the Danfoss AMV 110 NL and AMV 120 NL actuators.

Safety Information

To prevent injury to persons and damage to the device, it is absolutely necessary to read and observe these instructions carefully. Necessary assembly, start-up, and maintenance work must be performed by qualified and authorized personnel only. Please comply with the instructions of the system manufacturer or system operator.

Caution: Do not touch anything on the PCB.

Caution: Do not manually operate the drive under power!

Caution: Do not dismount the actuator from the valve when it is in a stem down position! If dismounted in a stem down position, there is a high risk that the actuator gets stuck.

Mounting

The actuator should be mounted with the valve stem in either a horizontal position or pointing upwards. The actuator is fixed to the valve body by means of a ribbed nut which requires no tools for mounting. The ribbed nut should be tightened by hand.

Wiring:

Installation

  1. Check the valve's neck. The actuator should be in the stem up position (factory setting). Ensure that the actuator is mounted securely on the valve body. It is obligatory to set the actuator's stem to the upper position before installing it on the AB-QM valve (refer to manual override diagrams).
  2. Energize the actuator according to the wiring diagram.
  3. The direction of stem movement can be observed on the position indicator.

A click after energizing the actuator indicates that the gear wheel has jumped into the normal position.

Manual Override (for service purposes only)

Procedure:

  1. Remove the cover.
  2. Press and hold the button (on the bottom side of the actuator) during manual override.
  3. Place cover back on the actuator.
  4. Install actuator on valve.

Dimensions

Type L (mm) H (mm) b (mm) ISO 228/1
DN 10 109 138 G1/2
DN 15 116 141 G 3/4
DN 20 125 143 G1
DN 25 142 155 G1 1/4
DN 32 160 166 G1 1/2

Hazardous Substances Table

Part Name Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr(VI)) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE)
Connecting nut X O O O O O

O: Indicates that this hazardous substance contained in all of the homogeneous material for this part is below the limit requirement in GB/T 26572;

X: Indicates that this hazardous substance contained in at least one of the homogeneous material for this part is above the limit requirement in GB/T 26572;

Models: AMV 110 NL, AMV 120 NL, AMV 110 NL AMV 120 NL Supply Voltage, AMV 110 NL Supply Voltage, AMV 120 NL Supply Voltage, Supply Voltage, AMV 110 NL AMV 120 NL Actuators for Three Point Control, AMV 110 NL Actuators for Three Point Control, AMV 120 NL Actuators for Three Point Control, Actuators, Actuators for Three Point Control, Three Point Control Actuators

File Info : application/pdf, 12 Pages, 2.17MB

PDF preview unavailable. Download the PDF instead.

instructions-d-installation-moteur-amv-110-nl-amv-120-nl-ast-1350423 Danfoss A/S Adobe PDF library 15.00

Related Documents

Preview Danfoss AMV 120 NL-1 Operating Guide
Comprehensive operating guide for the Danfoss AMV 120 NL-1 actuator, detailing safety precautions, mounting, wiring, installation, and manual override procedures for optimal performance.
Preview Danfoss AMV 130(H), AMV 140(H) Operating Guide
This operating guide provides essential information for the Danfoss AMV 130(H) and AMV 140(H) actuators, covering safety, mounting, wiring, installation, and manual override procedures.
Preview Danfoss Stellventile VR, VF und VFS: Datenblatt für Zwei- und Dreiwegeventile
Umfassendes Datenblatt von Danfoss für Stellventile der Serien VR, VF und VFS. Enthält technische Spezifikationen, Anwendungsbereiche, Bestellinformationen und Abmessungen für Zwei- und Dreiwegeventile.
Preview Danfoss ECL Comfort 120 Controller and App: Technical Data Sheet
Comprehensive technical data sheet for the Danfoss ECL Comfort 120 controller, detailing its features, specifications, heating control principles, communication capabilities, and recommended accessories for HVAC applications.
Preview Danfoss AMV 335, AMV 435 Operating Guide
This operating guide provides essential information for the Danfoss AMV 335 and AMV 435 actuators. It covers safety precautions, disposal instructions, mounting and wiring procedures, DIP switch settings, manual operation, LED indicators, and detailed dimensions for various valve configurations.
Preview Danfoss AVQML PN 25 Pressure Independent Control Valve Data Sheet
This Danfoss data sheet provides comprehensive technical specifications, ordering information, dimensions, and application details for the AVQML PN 25 pressure independent control valve with integrated flow limiter, suitable for district heating systems.
Preview Danfoss AME 120 NLX-1 Actuator Operating Guide
Operating guide for the Danfoss AME 120 NLX-1 actuator, covering installation, wiring, DIP switch settings, manual override, and function tests.
Preview Danfoss VIG 2, VIS 2, VIU 2, VIU 2-8 Installation and Configuration Guide
Comprehensive instructions for installing and configuring Danfoss VIG 2, VIS 2, VIU 2, and VIU 2-8 valves with various actuators, detailing system configurations and operational states (NO/NC).