LCGATEWAY/OFC
Daim ntawv qhia kev teeb tsa
Office Gateway Manual
LCGATEWAY-OFC Office Gateway
Welcome to lighting control that just works.
Lightcloud is a wireless, cloud-based lighting control system that’s incredibly easy to install. There’s no networking or complicated dip switches. Just wire the devices for power and let us know what was installed.
Cov ntsiab lus
- Office Gateway
- Hwj chim Cord
- Mounting Bracket
- Mounting Screws x 2
- Device ID Labels
- Phau ntawv
- Vaj Huam Sib Luag

Ntaus Specifications
PART NUMBER: LCGATEWAY/OFC
Kev ua haujlwm kub: 0 rau 40 ºC
MAXIMUM RELATIVE HUMIDITY: 95%
STORAGE AND TRANSPORTATION TEMPERATURE: -20º txog 40ºC
DIMENSIONS: 4.97" X 4.97" X 1.5"
AC POWER Input: Only use with provided power cord.
I NPUT VOLTAGE: 120 VAC, 50/60 HZ
Kev siv hluav taws xob: 60 mA @ 120v
Kev cai tsim nyob rau hauv Suav teb
Copyright © 2025 RAB Lighting, Inc.
![]()
Qhov System Tshajview
Lightcloud is a wireless, networked lighting control system that enables near limitless control over lighting. Lightcloud can be accessed from nearly anywhere and any device by logging in to control.lightcloud.com.
Lightcloud comes with 10 years of unlimited support, so feel free to contact us if you have any questions at 1 (844) LIGHTCLOUD.
Of fice Gateway
The Lightcloud Of fice Gateway serves two main functions:
- On-Site Coordination of Devices. The Office Gateway acts as an on-site brain for up to 200 Lightcloud® devices.
- Off-Site Coordination with Lightcloud.
The Office Gateway communicates with the Lightcloud® cloud for complete control of your system from anywhere.
An unlimited number of Gateways can be used for wireless control of any size Site.
Kev teeb tsa
- STEP IB
Muab lub rooj vag
a. Avoid problem materials and devices.
The Gateway needs to be able to communicate wirelessly with other Lightcloud Devices. Don’t place the
Gateway in a metal enclosure, thick concrete or brick rooms. Also, don’t place the Gateway near microwaves, elevator rooms, amplifiers, or other antennas.
PROBLEM MATERIALS
PROBLEM DEVICES & SIGNALS

NEEJ NEEG 
ELEVATOR MECHANICAL ROOMS 
AMPLIFIERS & ANTENNAS b. Choose a location that is as close to as many other Lightcloud devices as possible.
*All of the devices don’t have to be within a 100’ of the Gateway, but its ideal to have as many within direct range as possible. - KAUJ RUAM ob
Record the Gateway’s Device ID Each Lightcloud device has a unique Device ID for identification that needs to be documented. To document the Device IDs, use one of the following 3 methods.
a. LC Installer App – Free Scan Device IDs and send information to RAB Download: lightcloud.com/lcinstaller (Muaj rau iOS thiab Android)
b. Device Table – Included with the Gateway
Attach Device ID stickers to Device Table and complete information.
Send detailed photos of completed device table to support@lightcloud.com
Additional Device Tables can be downloaded at lightcloud.com/devicetable
c. Floor Plan
Attach the Device Identification sticker to its location on a floor plan, lighting design, or design schedule. Send detailed photos of completed plans to support@lightcloud.com.
- STEP peb
Nruab Gateway
a. Place Gateway on a surface or mount Gateway to wall using bracket and 2 supplied screws.
b. If using ethernet, plug in ethernet cable.
c. Plug in power cable.
d. Verify system status
Once all LEDs are solid white, you should be able to connect to your Gateway from control.lightcloud.com or the Lightcloud® Mobile App.
To check ZigBee (Device Mesh) signal strength, press the recessed device button once. A number of LEDs will turn blue indicating how strong the signal is, from 1 to 4, counting from the bottom up.LED Lub Xeev Lub ntsiab lus All LEDs solid white Khiav ib txwm All LEDs pulsing white Pib ua Some LEDs solid blue ZigBee signal strength All LEDs solid red Tseem ceeb tsis ua hauj lwm All LEDs pulsing red Tsis muaj kev sib txuas All LEDs pulsing green Gateway is in join mode - QHOV TSEEB
Install and Document Other Lightcloud® Devices a. Follow the Device Manuals to wire the other devices for permanent, unswitched power.
b. As you wire each device, document their Device IDs using the same method you chose to document the Gateway’s Device ID in step 3. - STEP FIV
Submit Device Information After wiring and organizing all the devices, submit the device information using the LC Installer App or email photos of the documented device IDs to support@lightcloud.com. - STEP SIV
Koj Ua Yog!
Lightcloud Support will remotely configure the system.
Cov Ntaub Ntawv FCC:
Cov cuab yeej no ua raws li Tshooj 15 ntawm FCC Cov Cai. Kev ua haujlwm yog ua raws li ob yam hauv qab no:
1. Cov cuab yeej no yuav tsis ua rau muaj kev cuam tshuam tsis zoo, thiab 2. Cov cuab yeej no yuav tsum lees txais kev cuam tshuam uas tau txais, suav nrog kev cuam tshuam uas yuav ua rau tsis muaj kev ua haujlwm.
Nco tseg: Cov cuab yeej no tau raug sim thiab pom tias ua raws li cov kev txwv rau Class B cov khoom siv digital raws li Tshooj 15 Subpart B, ntawm FCC cov cai. Cov kev txwv no yog tsim los muab kev tiv thaiv tsim nyog tiv thaiv kev cuam tshuam tsis zoo hauv thaj chaw nyob. Cov cuab yeej no tsim, siv, thiab tuaj yeem tawg lub zog ntawm xov tooj cua, thiab yog tias tsis tau nruab thiab siv raws li phau ntawv qhia, yuav ua rau muaj kev cuam tshuam rau kev sib txuas lus hauv xov tooj cua. Txawm li cas los xij, tsis muaj kev lees paub tias kev cuam tshuam yuav tsis tshwm sim hauv ib qho kev teeb tsa tshwj xeeb. Yog tias cov cuab yeej no ua rau muaj kev cuam tshuam tsis zoo rau lub xov tooj cua lossis TV txais tos, uas tuaj yeem txiav txim siab los ntawm kev tig cov khoom siv thiab qhib, tus neeg siv tau raug txhawb kom sim thiab kho qhov cuam tshuam los ntawm ib lossis ntau qhov kev ntsuas hauv qab no:
- Reorient lossis hloov chaw tus kav hlau txais xov.
- Ua kom muaj kev sib cais ntawm cov khoom siv thiab cov khoom txais.
- Txuas cov khoom siv rau hauv qhov hluav taws xob ntawm lub voj voog sib txawv ntawm qhov uas lub receiver txuas nrog.
- Tham nrog tus neeg muag khoom lossis tus kws tshaj lij xov tooj cua / TV rau kev pab.
To comply with the FCC’s RF exposure limits for general population / uncontrolled exposure, this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in
kev sib txuas nrog lwm lub kav hlau txais xov los yog xa khoom.
CEEB TOOM: Kev hloov lossis hloov kho rau cov cuab yeej no tsis tau pom zoo los ntawm RAB Teeb pom kev zoo yuav ua rau tus neeg siv txoj cai ua haujlwm cov khoom siv no tsis muaj.

Cov ntaub ntawv / Cov ntaub ntawv
![]() |