Specifications

  • Product Name: SLS 200 Plugs
  • Operating Voltage: Up to DC 150V
  • Operating Category: CAT II according to IEC/EN 61010-31 item 6.4.
  • Connection Type: Screw Terminal
  • Rated Voltage Measurement Category: 30 VAC / 60 VDC
  • Rated Current: 30 A
  • Material: Plug – Brass, Nickel Plated; Housing – PP
  • Inflammability Class: HB according to UL 94

Product Usage Instructions

  • Connection:
    Ensure the screw terminal connection is secure and properly tightened for efficient operation
  • Voltage Measurement:
    When measuring voltage, ensure it does not exceed the rated voltage of 30 VAC or 60 VDC to prevent damage to the plugs.
  • Current Rating:
    Observe the rated current of 30 A and consider any derating curve provided to ensure safe usage within the specified limits.
  • Material Care:
    Avoid exposure to corrosive substances that may degrade the brass or nickel plating of the plug. Keep the housing material (PP) clean and free from debris.
  • Safety Precautions:
    Do not use the plugs in applications beyond the specified temperature ranges without consulting the manufacturer. Ensure compliance with safety standards and regulations.

Specifications

Product SLS 200
description Contact-protected plug with screw connection for cables up to 2.5 mm², with onward connection capability (4 mm socket). Insulated by latching and sprung insulating sleeve, to be released by pressure on the lateral locking spring.

Plug with contact spring, 4mm diameter.

 

*For this typ up to DC 150 V, CAT II according to IEC/EN 61010-31 item 6.4., comment 4 allowed for devices with not yet protected sockets.

operating instruction BA412
article-no. /

*Color

9321531xx

 

00

black

 

 

01

red

 

 

02

blue

 

 

03

yellow

 

 

04

green

 

drawing  
  HIRSCHMANN-SLS-200-Plug-FIG
technical data  
connection screw terminal
rated voltage 30 VAC / 60 VDC
measurement cat. acc. to IEC 61010 O (2)
rated current

(consider derating curve)

30 A
material plug brass, nickel plated
housing material PP
temperature range acc. To IEC61010(1) -25 °C to +80 °C
inflammability class acc. to UL 94

(only valid for basic material of housing)

HB
  1.  contact the manufacturer for applications at deviating temperature ranges
  2. without rated measurement category, for other circuits that are not directly connected to the mains stand: 21.06.2022
  3. stand: 21.06.2022
  4. SKS Kontakttechnik GmbH | Neue Schichtstraße 14 | D-09366 Niederdorf | Phone +49-37296-930-300 | Fax +49 37296-930-301 | www.sks-kontakt.de | info@sks-kontakt.de 
  5. Downloaded from Arrow.com.

Frequently Asked Questions

  • Q: Can I use the SLS 200 plugs for mains connections?
    A: The SLS 200 plugs are rated for up to DC 150V and CAT II according to IEC/EN 61010-31 item 6.4. For circuits directly connected to mains, ensure compliance with safety guidelines and regulations.
  • Q: What is the recommended maximum current for the SLS 200 plugs?
    A: The rated current for the SLS 200 plugs is 30 A. Ensure you refer to any derating curve provided for specific applications.

Documents / Resources

PDF thumbnailSLS 200 Plug
Owner's Manual · SLS 200 Plug, SLS 200, Plug

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.