LANDSCAPE
Drawing 1 – Glass Installation
Assembly Instructions
Fixture No. 1508
Start Here
Glass Installation
- To install the glass and lamp the fixture, start by holding the glass (2) in place over the socket (1) and thread the glass holder ring (3) onto the socket.
- Lamp the fixture with bulb (5) into socket (1).
- Thread on bulb shield (6) onto socket (1)
- Fixture can now be powered on
Luminaire Mounting: (for typical ground spike mounting)
- To prevent electrical shock, disconnect transformer from electrical supply before installation or service.
- Run wire from luminaire through mounting hole in top of ground spike.
- Attached luminaire to ground spike by threading to mounting hole in spike.
- Place spike in desired position and insert into ground until the flange of spike is flush with ground.
- Strip the two wire leads from the Luminaire and connect to the main supply wire using the provided silicone filled wirenut.
Note: Wire is to be protected by routing in close proximity to the Luminaire or fitting or next to a building structure such as a house or deck. Wiring should be buried a maximum of 6 inches (15.2cm) in order to connect to main supply wire. The main supply wire must have its length cut off within 6 inches (15.2cm) from a building structure, a Luminaire or fitting.