HINKLEY Logo

LANDSCAPE

Drawing 1 – Glass Installation

HINKLEY 1508CB-LL Ivy LED Path Light

Assembly Instructions

Fixture No. 1508
HINKLEY 1508CB-LL Ivy LED Path Light - Icon Start Here
Glass Installation

  1. To install the glass and lamp the fixture, start by holding the glass (2) in place over the socket (1) and thread the glass holder ring (3) onto the socket.
  2. Lamp the fixture with bulb (5) into socket (1).
  3. Thread on bulb shield (6) onto socket (1)
  4. Fixture can now be powered on

HINKLEY 1508CB-LL Ivy LED Path Light - Luminaire

Luminaire Mounting: (for typical ground spike mounting)

  1. To prevent electrical shock, disconnect transformer from electrical supply before installation or service.
  2. Run wire from luminaire through mounting hole in top of ground spike.
  3. Attached luminaire to ground spike by threading to mounting hole in spike.
  4. Place spike in desired position and insert into ground until the flange of spike is flush with ground.
  5. Strip the two wire leads from the Luminaire and connect to the main supply wire using the provided silicone filled wirenut.

Note: Wire is to be protected by routing in close proximity to the Luminaire or fitting or next to a building structure such as a house or deck. Wiring should be buried a maximum of 6 inches (15.2cm) in order to connect to main supply wire. The main supply wire must have its length cut off within 6 inches (15.2cm) from a building structure, a Luminaire or fitting.

HINKLEY 33000 Pin Oak Parkway,
Avon Lake, OH 44012 800.446.5539 / 440.653.5500