HILTI HIK-T Distance Fixing System

HILTI-HIK-T-Distance-Fixing-System-PRODUCT

Product Information

Specifications

  • Product Name: Hilti HIK-T Distance Fixing System
  • Model Numbers: HIK-T 12, HIK-T 16
  • Manufacturer: HILTI Corporation
  • Manufacturing Plant: HILTI plants
  • Intended Use: Fixings through an ETICS into the loadbearing wall of heavy-duty fixtures

Product Usage Instructions

Technical Description
The HILTI HIK-T 12 and HIK-T 16 are postinstalled anchor systems placed into predrilled holes in concrete, masonry, and anchored by bonding.

Intended Use
The system is used for distance installations in insulated base materials for heavy-duty fixtures like awnings, French balconies, canopies, satellite dishes, etc.

Installation Temperature
The minimum and maximum installation temperature are specified by the manufacturer within the specified range.

Performance Conditions
The performances of the product are valid only if used in compliance with the specifications and conditions given in Annex B1 to B5 of the manual.

Warnings
Ensure no debris or remaining ETICS/inulations influence the load-bearing capacity in the base material when using the product in ETICS or insulations.

European Technical Assessment ETA-22/0275 of 2023/07/24

General Part

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: ETA-Danmark A/S

HILTI-HIK-T-Distance-Fixing-System-FIG- (1)

Translations of this European Technical Assessment in other languages shall fully correspond to the original issued document and should be identified as such.

Communication of this European Technical Assessment, including transmission by electronic means, shall be in full (except the confidential Annexes referred to above). However, partial reproduction may be made, with the written consent of the issuing Technical Assessment Body. Any partial reproduction has to be identified as such.

SPECIFIC PART OF THE EUROPEAN TECHNICAL ASSESSMENT

Technical description of product 

Technical description of the product
HILTI HIK-T 12 and HILTI HIK-T 16 are post-installed anchor systems placed into predrilled holes in concrete, in masonry and anchored by bonding.
HILTI HIK-T 12 or HILTI HIK-T 16 distance fixing systems consist of a M12 or M16 threaded rod made from carbon steel or stainless steel and a thermal separation module made from polyamide. The fixing system is placed into a pre-drilled hole perpendicular to the surface (maximum deviation 5°) in masonry or concrete, and anchored by bonding the threaded rod element to the wall of the drilled hole.

The product description is given in Annex A.

Specification of the intended use in accordance with the applicable European Assessment Document (hereinafter EAD)

The intended use is fixings through an ETICS into the loadbearing wall of heavy-duty fixtures such as awnings, French balconies, canopies, satellite dishes, etc.
The system is used for distance installations in the following insulated base materials:

  • Normal weight cracked or non-cracked concrete (base material group a)
  • Solid masonry bricks (base material group b)
  • Perforated or hollow bricks (base material group c)
  • autoclaved aerated concrete (base material group d)

Reference to base material group in EAD 330499-02-0601 and EAD 330076-00-0604.

Anchorages subject to: Static or quasi-static loads.

Temperature range:

  • T1: -40°C to +40°C (max. short term temperature +40°C and max. long-term temperature +24°C)
  • T2: -40 °C to +80 °C (max long term temperature +50 °C and max short term temperature +80 °C)

The minimum and the maximum installation temperature are specified by the manufacturer within the above range.

Use categories in respect of use:

  • Category d/d: Use in dry masonry and concrete Category
  • w/w: Use in wet masonry only.

This ETA applies only where concrete or masonry members in which the distance fixing systems are embedded are subject to static or quasi static actions in tension, pressure, shear or combined tension and shear or pressure and shear or bending.

In case of a product use in ETICS or insulations, it must be ensured that no debris and remaining of ETICS or insulations influence the load bearing capacity in the base material.

  • The performances given in Section 3 are only valid if the anchor is used in compliance with the specifications and conditions given in Annex B1 to B5.
  • The provisions made in this European Technical Assessment are based on an assumed intended working life of the anchor of 50 years.
  • The indications given on the working life cannot be interpreted as a guarantee given by the producer or Assessment Body but are to be regarded only as a means for choosing the right products in relation to the expected economically reasonable working life of the works.

Performance of the Product

Performance of the product and references to the methods used for its assessment

Characteristics of product 

Safety in case of fire (BWR 2): 

Essential characteristic Performance
Reaction to fire A1 for metal parts and bonding material
Façade fire performance No performance assessed

Safety in use (BWR4):

Resistance of the M12 resp. M16 anchor rod fixed with anchor adhesive in the base material masonry: The M12 or M16 rod with material specification as stated in annex A5 are covered by the following ETAs which provide the relevant performances:

  • ETA-13/1036 for Hilti HIT-HY 270
  • ETA-19/0160 for Hilti HIT-HY 270
  • ETA-15/0197 for Hilti HIT-HY 170
  • ETA-19/0161 for Hilti HIT-HY 170
  • ETA-16/0239 for Hilti HIT-MM Plus

Resistance of the M12 or M16 anchor rod fixed with anchor adhesive in the base material concrete: The M12 resp. M16 rod with material specification as stated in annex A5 are covered by the following ETAs which provide the relevant performances:

For cracked and uncracked concrete

  • ETA-11/0354 for Hilti HIT-CT 1
  • ETA-14/0457 for Hilti HIT-HY 170
  • ETA-19/0465 for Hilti HIT-HY 170
  • ETA-11/0493 for Hilti HIT-HY 200-A
  • ETA-12/0084 for Hilti HIT-HY 200-R
  • ETA-19/0601 for Hilti HIT-HY 200-A/R V3

For uncracked concrete:

  • ETA-17/0199 for Hilti HIT-MM Plus

Resistance of the plastic part 

  • Characteristic resistance of the plastic part transferring load to failure under tension loading
  • Characteristic resistance of the plastic part transferring load to failure under pressure loading
  • Characteristic resistance of the plastic part transferring load to failure under shear loading
  • Characteristic resistance to failure under pressure load and displacement (buckling of cantilever arm)
  • Characteristic resistance to failure under combined shear and pressure load and displacements (buckling of cantilever arm)
  • Characteristic resistance under shear loads and displacements (failure of plastic part transferring load, cantilever arm)
  • Maximum installation torque moment

The above essential characteristics are detailed in Annex C.

Energy economy and heat retention (BWR6)

  • Point thermal transmittance
  • Equivalent thermal conductivity

The above essential characteristics are detailed in Annex C.

Durability
The verification of durability is part of testing of the essential characteristics. Durability is only ensured if the specifications of intended use according to Annex B are taken into account.

Methods of assessment
The assessment of fitness of the anchor for the intended use in relation to the requirements for mechanical resistance and stability and safety in use in the sense of the Basic Requirements 4 has been made in accordance with the EAD 331985- 01-0604 – Distance fixing system.

Assessment and verification of constancy of performance (AVCP)

AVCP system
According to the decision 97/463/EC of the European Commission, the system(s) of assessment and verification of constancy of performance (see Annex V to Regulation (EU) No 305/2011) is 2+.

Technical Details

Technical details necessary for the implementation of the AVCP system, as foreseen in the applicable EAD

Technical details necessary for the implementation of the AVCP system are laid down in the control plan deposited at ETA-Danmark prior to CE marking.

HILTI-HIK-T-Distance-Fixing-System-FIG- (2)

HILTI-HIK-T-Distance-Fixing-System-FIG- (3)

Product description

View and profile of the products

HIK-T 12 and HIK-T 16 installed conditions
Single fixing – anchor’s free end is rotatable under an acting shear load

HILTI-HIK-T-Distance-Fixing-System-FIG- (4)

Multiple fixing – anchor’s free end is not rotatable under an acting shear load, provided that the fixed baseplate is sufficiently rigid

HILTI-HIK-T-Distance-Fixing-System-FIG- (5)

HILTI-HIK-T-Distance-Fixing-System-FIG- (6)

Table A3.1: Specifications for the installation

HILTI-HIK-T-Distance-Fixing-System-FIG- (21)

HIK-T 12, HIK-T 16 installed conditions to ensure sealing against driving rain (watertightness in accordance with EN 1027 – method 1A)

HILTI-HIK-T-Distance-Fixing-System-FIG- (7)

Installation with max. distance of plaster to fixture to ensure water tightness (a ≤ 3,5 mm)

Marking:

HILTI-HIK-T-Distance-Fixing-System-FIG- (8)

HIK-T 12, HIK-T 16 single parts and materials

HILTI-HIK-T-Distance-Fixing-System-FIG- (9)

Table A 5.1: Parts and Materials

HILTI-HIK-T-Distance-Fixing-System-FIG- (22)

Specification of intended use

Anchorages subject to:
Static and quasi-static actions in tension, pressure, shear or combined tension and shear or combined pressure and shear load. The anchor shall not be used for the transmission of dead loads of the thermal insulation composite system.

Base material:
Masonry – in accordance with ETAs

  • ETA-13/1036 for Hilti HIT-HY 270
  • ETA-19/0160 for Hilti HIT-HY 270
  • ETA-15/0197 for Hilti HIT-HY 170
  • ETA-19/0161 for Hilti HIT-HY 170
  • ETA-16/0239 for Hilti HIT-MM Plus

Cracked and uncracked concrete – in accordance with ETAs

  • ETA-11/0354 for Hilti HIT-CT 1
  • ETA-19/0465 for Hilti HIT-HY 170
  • ETA-14/0457 for Hilti HIT-HY 170
  • ETA-11/0493 for Hilti HIT-HY 200-A
  • ETA-12/0084 for Hilti HIT-HY 200-R
  • ETA-19/0601 for Hilti HIT-HY 200-A/R V3

Uncracked concrete – in accordance with ETAs for uncracked concrete

  • ETA-17/0199 for Hilti HIT-MM Plus based
    Temperature Range for use – if not restricted by injection adhesive ETA:

Masonry

  • Ta: – 40°C to + 40°C (max. temperature: short-term +40°C and long-term +24°C)
  • Tb: – 40°C to + 80°C (max. temperature: short-term +80°C and long-term +50°C)

Concrete

  • T1: – 40°C to + 40°C (max. temperature: short-term +40°C and long-term +24°C)
  • T2: – 40°C to + 80°C (max. temperature: short-term +80°C and long-term +50°C)

Use conditions (Environmental conditions)
The use conditions for the base materials are given in the above-mentioned ETAs for the respective substrates.

Steel parts in respect of installation and application conditions:
The intended use regarding environmental conditions of anchors with components made of stainless steel, results from their corrosion resistance class in accordance with (CRC) to EN 1993-1-4:2006+A1:2015,

Table A.3 in connection with EN 1993-1-4:2006+A1:2015, Table A.2 and A.1.

  • The fastener consisting of exterior and interior parts made of stainless-steel class A4 in accordance with Annex A5, table A5.1: CRC III.
  • The fastener consisting of exterior parts made of stainless-steel class A4 in accordance with Annex A5, table A5.1 and interior parts made of galvanized carbon steel in accordance with annex A5, table A5.1: CRC III, provided that the anchor and sealing ring is installed in accordance with annex A4 and a displacement less than 1.0 mm under tension loads and less than 3.0 mm under shear loads, and with a render with a maximum grain size K3.
  • Furthermore, it is required that the ETICS or insulation is designed to avoid accumulation of humidity. The fastener consisting of exterior parts made of stainless-steel class A4 in according with Annex A5, table A5.1 and interior parts made of galvanized carbon steel in according with annex A5, table A5.1: CRC III, provided that other suitable sealing measures are taken, such as a hybrid joint compound or e.g., a sheet metal cover is applied

Use conditions in respect of installation and use
Masonry base material – if not restricted by the ETA for the anchor adhesive:

  • Category d/d: Installation and use in dry masonry
  • Category w/w: Installation and use in wet or dry masonry (incl. w/d installation in wet masonry and use in dry masonry)
    Concrete base material – if not restricted by the ETA for the anchor adhesive:
  • I1: installation in dry or wet (water saturated) concrete and use in dry or wet concrete
  • I2: installation in water-filled drill holes (not sea water) and use in dry or wet concrete
  • D3: downward and horizontal and upwards (e.g. overhead) installation

Design:

  • The anchorages are to be designed under the responsibility of an engineer experienced in anchorages and masonry work with the applicable safety factors.
  • Verifiable calculation notes and drawings shall be prepared taking account of the loads to be anchored, the nature and strength of the base materials and the dimensions of the anchorage members as well as of the relevant tolerances. The position of the anchor is indicated on the design drawings.
  • The fastener is anchored in the substrate of concrete or masonry. Any other layer e.g.,tolerance levelling layers, adhesives, plaster covering the substrate or outside plasters are considered as to be non-load bearing.
  • The anchorage design shall be done in accordance with EOTA TR 077:2022.
  • HILTI-HIK-T-Distance-Fixing-System-FIG- (23) = 1 for compression load for solid base material and for hollow base material with more than 4 penetrated webs.

Installation:

  • Dry or wet structures
  • Anchor Installation carried out by appropriately qualified personnel and under the supervision of the person responsible for technical matters of the site.
  • Hole drilling in concrete by hammer or compressed air drill mode
  • Temperature of the anchor system at installation from -20°C to + 40°C.
  • Exposure to UV due to solar radiation of the plastic part not protected ≤ 6 weeks.

Table B 2.1: Installation parameters in base material (see drawing in Annex A2)

HILTI-HIK-T-Distance-Fixing-System-FIG- (24)

For hollow base material a perforated sleeves must be used for the anchor adhesive, in accordance with ETA of anchor adhesive.
*Tinst = 19 Nm resp. 25 Nm are valid for the thermal separation module. Max. Tinst given in ETAs of anchor adhesive must also be observed.

a) as delivered with threaded pin M12 or with reduction threaded pin M12/M10
b) with any longer threaded rod, washer and nut which complies to the specifications given in table A 5.1 position 3 and 3a. The introduction of bending moment is not allowed. Constructive measures must be applied to exclude any bending moment.

HILTI-HIK-T-Distance-Fixing-System-FIG- (10)

Intended use

Installation parameters

HIK-T 12, HIK-T 16: Installation instruction (in concrete or solid masonry)

HILTI-HIK-T-Distance-Fixing-System-FIG- (11)

HILTI-HIK-T-Distance-Fixing-System-FIG- (12)

HIK-T 12, HIK-T 16: Installation instruction (in hollow masonry)

HILTI-HIK-T-Distance-Fixing-System-FIG- (13)

HILTI-HIK-T-Distance-Fixing-System-FIG- (14)

Table B9.1 Conditions for proper installation and additional advice for installation

Note: Driving rain resistance must be designed in accordance with the provisions given in annex B2 for fasteners with an interior part made of galvanized steel.

HILTI-HIK-T-Distance-Fixing-System-FIG- (25)

External Thermal Insulations Composite Systems (ETICS) or rendered insulation with reinforced plaster which are glued only or glued and mechanically fixed.
** ≥ 5 kPa is a guideline value that the thermal separation module can apply sufficient pre-tensioning force in the insulation panel to ensure the compression of the sealing ring.

The values stated are to be understood as guideline values in order to give the user the highest possible application safety

Table C1.1: Characteristic tensile load resistance NRk,s of the anchor rods

HILTI-HIK-T-Distance-Fixing-System-FIG- 26

*In absence of other national regulations

Table C1.2: Characteristic shear load resistance VRk,s without lever arm and characteristic bending resistance MRk,s of the anchor rods

HILTI-HIK-T-Distance-Fixing-System-FIG- 27

Table C2.1: Characteristic buckling load resistance PRk,ca for the system of threaded rod and thermal separation module under pressure load with or without shear load displacement HILTI-HIK-T-Distance-Fixing-System-FIG- 43

HILTI-HIK-T-Distance-Fixing-System-FIG- (15)

HILTI-HIK-T-Distance-Fixing-System-FIG- 28

HILTI-HIK-T-Distance-Fixing-System-FIG- 44 for buckling in accordance with EOTA TR 077
**calculated values in accordance with Euler cases were decisive for the determination of performance

Performances

Characteristic buckling load under pressure load

Table C3.1: Characteristic tensile load resistance NRk,tk against short- and long-term acting loads for the thermal separation module

HILTI-HIK-T-Distance-Fixing-System-FIG- 29

HILTI-HIK-T-Distance-Fixing-System-FIG- 45 for plastic material polyamide in accordance with EOTA TR 077
The min. screw in depths of the rods (Ls1, Ls2) must be observed

Table C3.2: Characteristic pressure load resistance PRk,tk against short- and long-term acting loads for thermal separation module

HILTI-HIK-T-Distance-Fixing-System-FIG- 30

HILTI-HIK-T-Distance-Fixing-System-FIG- 45 for plastic material polyamide in accordance with EOTA TR 077
Pressure load in base material must be considered

Table C4.1: Characteristic shear load resistance VRk,tk against short- and long-term acting loads for a single thermal separation module – free end rotatable

HILTI-HIK-T-Distance-Fixing-System-FIG- (16)

Table C4.2: Characteristic shear load resistance VRk,tk against short- and long-term acting loads for a single thermal separation module – free end not rotatable

HILTI-HIK-T-Distance-Fixing-System-FIG- (17)

Table C5.1: Shear load V values for a single HIK-T 12 for displacements w = 1, 2, 3, 4 or 5 mm – free end rotatable, under short-term acting load

HILTI-HIK-T-Distance-Fixing-System-FIG- 31

Intermediate values can be interpolated. Data are limited due to ultimate limit state verifications of the performance given in Annex C4 under consideration of HILTI-HIK-T-Distance-Fixing-System-FIG- 46M=2.5 and HILTI-HIK-T-Distance-Fixing-System-FIG- 47F=1.4

Table C5.2: Shear load V values for a single HIK-T 12 for displacements w = 1, 2, 3, 4 or 5 mm – free end rotatable, under long-term acting load

HILTI-HIK-T-Distance-Fixing-System-FIG- 32

Intermediate values can be interpolated. Data are limited due to ultimate limit state verifications of the performance given in Annex C4 under consideration of HILTI-HIK-T-Distance-Fixing-System-FIG- 46M=2.5 and HILTI-HIK-T-Distance-Fixing-System-FIG- 47F=1.4

Table C6.1: Shear load V values for a single HIK-T 12 for displacements w = 1, 2, 3, 4 or 5 mm – free end not rotatable, under short-term acting load

HILTI-HIK-T-Distance-Fixing-System-FIG- 33

Intermediate values can be interpolated. Data are limited due to ultimate limit state verifications of the performance given in Annex C4 under consideration of HILTI-HIK-T-Distance-Fixing-System-FIG- 46M=2.5 and HILTI-HIK-T-Distance-Fixing-System-FIG- 47F=1.4

Table C6.2: Shear load V values for a single HIK-T 12 for displacements w = 1, 2, 3, 4 or 5 mm – free end not rotatable, under long-term acting load

HILTI-HIK-T-Distance-Fixing-System-FIG- 34

Intermediate values can be interpolated. Data are limited due to ultimate limit state verifications of the performance given in Annex C4 under consideration of HILTI-HIK-T-Distance-Fixing-System-FIG- 46M=2.5 and HILTI-HIK-T-Distance-Fixing-System-FIG- 47F=1.4

Table C7.1: Shear load V values for a single HIK-T 16 for displacements w = 1, 2, 3, 4 or 5 mm – free end rotatable, under short-term acting load

HILTI-HIK-T-Distance-Fixing-System-FIG- 35

Intermediate values can be interpolated/ Data are limited due to ultimate limit state verifications of the performance given in Annex C4 under consideration of HILTI-HIK-T-Distance-Fixing-System-FIG- 46M=2.5 and HILTI-HIK-T-Distance-Fixing-System-FIG- 47F=1.4

Table C7.2: Shear load V values for a single HIK-T 16 for displacements w = 1, 2, 3, 4 or 5 mm – free end rotatable, under long-term acting load

HILTI-HIK-T-Distance-Fixing-System-FIG- 36Intermediate values can be interpolated/ Data are limited due to ultimate limit state verifications of the performance given in Annex C4 under consideration of HILTI-HIK-T-Distance-Fixing-System-FIG- 46M=2.5 and HILTI-HIK-T-Distance-Fixing-System-FIG- 47F=1.4

Table C8.1: Shear load V values for a single HIK-T 16 for displacements w = 1, 2, 3, 4 or 5 mm – free end not rotatable, under short-term acting load

HILTI-HIK-T-Distance-Fixing-System-FIG- 37Intermediate values can be interpolated/ Data are limited due to ultimate limit state verifications of the performance given in Annex C4 under consideration of HILTI-HIK-T-Distance-Fixing-System-FIG- 46M=2.5 and HILTI-HIK-T-Distance-Fixing-System-FIG- 47F=1.4

Table C8.2: Shear load V values for a single HIK-T 16 for displacements w = 1, 2, 3, 4 or 5 mm – free end not rotatable, under long-term acting load

HILTI-HIK-T-Distance-Fixing-System-FIG- 38Intermediate values can be interpolated/ Data are limited due to ultimate limit state verifications of the performance given in Annex C4 under consideration of HILTI-HIK-T-Distance-Fixing-System-FIG- 46M=2.5 and HILTI-HIK-T-Distance-Fixing-System-FIG- 47 F=1.4

HILTI-HIK-T-Distance-Fixing-System-FIG- 39

Point thermal transmittance

HILTI-HIK-T-Distance-Fixing-System-FIG- (20)

Table C10.1: Thermal conductivity values used for the determination of equivalent thermal conductivity

HILTI-HIK-T-Distance-Fixing-System-FIG- 40

Table C11.1: The equivalent thermal conductivity HILTI-HIK-T-Distance-Fixing-System-FIG- 48

HILTI-HIK-T-Distance-Fixing-System-FIG- 41

* derived from the calculation with HIK-T 16

Table C11.2: Point thermal transmittances for thermal conductivity HILTI-HIK-T-Distance-Fixing-System-FIG- 49

HILTI-HIK-T-Distance-Fixing-System-FIG- 42

* derived from the calculation with HIK-T 16

FAQ

Q: Can the HIK-T Distance Fixing System be used in all types of base materials?
A: The system is specifically designed for use in concrete and masonry members subject to static or quasi-static actions in tension, pressure, shear, or bending.

Q: What is the minimum and maximum installation temperature for the HIK-T system?
A: The minimum and maximum installation temperatures are specified by the manufacturer within the specified range. Please refer to the product manual for exact values.

Q: Are there any specific performance conditions to be met for using this product?
A: Yes, the performances of the product are valid only if used in compliance with the specifications and conditions given in Annex B1 to B5 of the manual.

Documents / Resources

HILTI HIK-T Distance Fixing System [pdf] Instruction Manual
HIK-T 12, HIK-T 16, HIK-T Distance Fixing System, Distance Fixing System, Fixing System

References

Leave a comment

Your email address will not be published. Required fields are marked *