E-nr Snro El.nr GTIN Name LED color Color Unit effect
7218567 4318373 3227639 7392971148946 Liteline Basic IP44 600 830 3000K White 18W
7218569 4318375 3227641 7392971148960 Liteline Basic IP44 600 S 830* 3000K White 18W
7218568 4318374 3227640 7392971148953 Liteline Basic IP44 600 840 4000K White 18W
7218570 4318376 3227642 7392971148977 Liteline Basic IP44 600 S 840* 4000K White 18W

hide a lite IP44 600 Liteline Basic 1

For explanation of symbols see www.hidealite.com

hide a lite IP44 600 Liteline Basic 2

SAFETY INSTRUCTIONS

Read these instructions carefully before commencing installation and retain for future reference. The luminaire should be installed by a licensed electrician and in accordance with local regulations. Make sure that the power is off before installation or maintenance.

Accessories

hide a lite IP44 600 Liteline Basic 3

Installation

hide a lite IP44 600 Liteline Basic 4 hide a lite IP44 600 Liteline Basic 5 hide a lite IP44 600 Liteline Basic 6

Function motion sensor

  1. Range – The range is the area the sensor covers. The units lights when motion is sensed in the area. Set the DIP switch as follows to adjust the sensor’s range.
  2. Hold Time – A delay time concerns the time the unit remains lit after the person leaves the sensor’s range. Set the DIP switch as follows to adjust the sensor’s hold time
  3. Daylight sensor – Set the daylight sensor as per the DIP switch for different activation values. The unit functions as per the settings below: Disable: Sensor always active, even in daylight. 50 Lux: Sensor active from slight light reduction. 10 Lux: Sensor active from almost dark. 2 Lux: Sensor active from totally dark.

hide a lite IP44 600 Liteline Basic 7

hide a lite IP44 600 Liteline Basic 8

With insufficient ambient light, the sensor switches on the lamp when motion is detected

hide a lite IP44 600 Liteline Basic 9

UC06
Operating voltage 220~240VAC, 50/60Hz
Rated load 400W(inductive), 800W (resistive)
HF system 5.8GHz±75MHz
Transmitting power <0.2mW
Power consumption <0.2W(standby)
Detection zone Max.(D x H): 10m x 3m
Detection sensitivity 25% / 50% / 75% / 100%
Hold time 5s/30s/1min/3min/5min/10min/  20min/30min
Daylight sensor 2lux / 10lux / 25lux/ 50lux / Disable
Mounting height 5m Max.
Detection angle 30°(wall installation) 150°(ceiling installation)
Operating temperature -20°C ~ 60°C
IP rating IP20

hide a lite IP44 600 Liteline Basic 10

Installation – Wall attachment

hide a lite IP44 600 Liteline Basic 11

Elektro Elco AB, Tallvägen 5, SE-56435 Bankeryd, Sweden | info@elco.se | www.hidealite.se | www.hidealite.uk | www.hidealite.fi | www.hidealite.no | www.hidealite.dk

Documents / Resources

PDF thumbnailIP44 600 Liteline Basic
Instruction Manual · IP44 600 Liteline Basic, IP44 600, Liteline Basic, Basic

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.