HELTEC HRI-3632 Wireless Aggregator Owner’s Manual
HELTEC HRI-3632 Wireless Aggregator

Document version

Version Time Description Remark
Rev. 1.0 2023-4-26 Preliminary version Richard

Copyright Notice

All contents in the files are protected by copyright law, and all copyrights are reserved by Chengdu Heltec Automation Technology Co., Ltd. (hereinafter referred to as Heltec).
Without written permission, all commercial use of the files from Heltec are forbidden, such as copy, distribute, reproduce the files, etc., but non-commercial purpose, downloaded or printed by individual are welcome.

Disclaimer

Chengdu Heltec Automation Technology Co., Ltd. reserves the right to change, modify or improve the document and product described herein. Its contents are subject to change without notice. These instructions are intended for you use.

Description

Overview
Wireless Aggregator is a Lora Wan converter belonging to Wireless Aggregator series, used to drive various third-party RS-485 sensors. We have equipped it with a junction box so that it can also drive 4 to 20mA sensors. Benefits from the IP66 protection provided by high-strength plastics, it can adapt to a variety of complex outdoor environments.
Wireless Aggregator has the characteristics of low power consumption and long transmission distance. Built-in large capacity rechargeable battery, which can be charged through the DC power and solar interface, ensures that it can work stably for a long time.

Product features

  • IP66 protection grade, Lightning protection design, ESD protection and isolation.
  • Ultra-low power consumption design.
  • With special junction box, interface compatibility is strong.
  • Built-in 2000mAh x4 rechargeable battery, can be charged by DC and solar energy.
  • Wireless data transmission communication radius up to 5km.
  • Working condition: -40~80°C, Working humidity: ≤90% (non-condensing).
  • Power supply mode: built-in battery or external 5~24V DC powersupply.
  • APP scan QR code for registration, or configure via Wi-Fi, supports OTA update.
    Product features

Specifications

General specification

Parameters Description
Temperature -40 ~ 80 °C1
Humidity 0 ~ 90% RH (non condensing)
Microcontroller Heltec Wireless Shell
Interface Flange seat (see 3.2
LoRa WAN Channel Plan EU868/US915/AU915/ AS923/KR920/RU864/CN470
External Power Supply and Charging Voltage 7~24V, 7~48V2
Power Out 5V/9V/12V, 7~24V, 7~48V3
Max. Receiving sensitivity -134dBm@SF12 BW=125KHz
Max. TX Power 21± 1dBm
Signal Range 5km (depending on gateway antenna and environments)
IP Rating IP66
Battery Capacity 2000mAh x4
  1. PCB and battery operating temperature, more than 60 degrees will affect the life of the battery, and please pay attention to the working temperature of the sensor.
  2. 7~24V and 7~48V are different pin inputs, 7~24V input can charge the built-in battery, 7~48V does not.
  3. The built-in battery output is 5/9/12V, set in the device configuration page, and the corresponding dial switch should be selected on the device in advance. When other voltage output modes are selected, the output voltage is equal to the input voltage.

Operating conditions

Power supply range

Table 2.2: Power supply range

Parameters Battery 7~24V Pin 7~48V Pin
Input 3.3~4.1V 7~24V 7~48V
Output 5/9/12V 5/9/12V 7~24V 5/9/12V 7~48V

Power consumption

Table 2.2.1: Working current

Mode Condition Typical Unit
Active-Mode (TX) TX power is 22dBm 220 mA
Active-Mode (RX) TX disabled; RX enabled 50 mA
Deep sleep 28 μA

RF Characteristics

The following table gives typically sensitivity level of the HRI-363x .
Table 2.4: LoRa RF characteristics

Signal Bandwidth/[KHz] Spreading Factor Sensitivity/[dBm]
125 SF12 -134
125 SF11 -132
125 SF10 -130
125 SF9 -127
125 SF8 -124
125 SF7 -122

LoRaWAN Frequency

Note: No Frequency limitation. EU868 can be switched to RU864, US915 can be switched to 915/AS923/KR920.

NO Frequency band Common band
1 EU863-870 EU868
2 US902-928 US915
3 AU915-928 AU915
4 AS923_1 As923
5 AS923_2 As923
6 KR920-923 KR920
7 RU864-867 RU864
8 CN470-510 CN470

Hardware Resources

Physical dimensions (Unit:mm)
Physical dimensions (Unit:mm

Interface Definition

Flange seat A-DC
Interface Definition
Flange seat B-Sensor
Interface Definition

Resource

Relevant resource

Heltec Contact Information

Heltec Automation Technology Co., Ltd Chengdu, Sichuan, China
Email: support@heltec.cn
Phone: +86-028-62374838
https://heltec.org

FCC Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

To assure continued compliance, any changes or modifications not expressly approved by the party.
Responsible for compliance could void the user’s authority to operate this equipment. (Example- use only shielded interface cables when connecting to computer or peripheral devices).

This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

FCC Radiation Exposure Statement:
The equipment complies with FCC Radiation exposure limits set forth for uncontrolled enviroment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.