EXEC™ Operating Instructions

Key Features

  • Accuracy: ±0.9°F (±0.5°C)
  • Reading Speed: 3-4 second readings
  • Temperature Range: -40 to 572°F (-40 to 300°C)
  • Durability: IP67 rating (water and dust resistant)
  • Display: 180° rotating display
  • Additional Functions: Backlight, Max/Min function
  • Certification: NIST-traceable certificate

Instrument Operation

To turn on the EXEC thermometer, press the power button. The unit will automatically turn off after 35 minutes to conserve battery life. To manually turn off the device, press and hold the power button for 3 seconds. The backlight can be activated by pressing the power button once while the instrument is on; press again to turn it off.

Insert the stainless steel probe into the food item to the desired depth. The measured temperature will be displayed on the LCD screen within 3 to 4 seconds.

Visual Description: The EXEC thermometer features a stainless steel probe and a digital display. It has buttons for power, MAX/MIN, and °C/°F selection. The device is branded with the EXEC and NSF logos.

Using MIN/MAX Function

Press the MAX/MIN button to view the highest recorded temperature. Press the button again to view the lowest recorded temperature. Pressing it a third time returns the display to the normal temperature reading. To reset the stored maximum and minimum temperature memory, press and hold the MAX/MIN button for three seconds. The MAX and MIN values are also reset when the unit is powered off.

Battery Installation

When the low battery indicator 'Bat' flashes on the display, replace the battery. The thermometer uses one 3-volt CR1632 button-cell battery or equivalent. To replace the battery, use a suitable screwdriver to open the battery cover located on the back of the unit. Ensure the new battery is inserted with the correct polarity (positive side '+' facing up) and slide it under the metal clip. Close the battery cover securely.

Selecting Temperature Units (°F or °C)

Press the °C/°F button on the back of the thermometer to switch between Fahrenheit (°F) and Celsius (°C) temperature units.

Calibration Trim

The EXEC thermometer is factory calibrated to read within ±0.9°F. Calibration adjustments are typically not necessary. For instructions on performing a one-point calibration trim, please visit the EXEC product page on the ThermoWorks website.

Care and Cleaning

Clean the probe immediately after each use to prevent cross-contamination. Avoid exposing the thermometer body to temperatures exceeding 122°F (50°C). Do not leave the thermometer inside hot ovens. Do not submerge the entire thermometer in liquid.

Technical Support and Resources

For warranty, service, or technical assistance, contact ThermoWorks Technical Support at (801) 756-7705 or email techsupport@thermoworks.com. For additional cooking tips, doneness temperatures, and to explore the full range of ThermoWorks products, visit their website at www.thermoworks.com.

Specifications

Probe Range-40 to 572°F (-40 to 300°C)
Accuracy±0.9°F (±0.5°C) between 14 to 212°F (−10 to 100°C), ±4.5°F (±2.5°C) between 392 to 572°F (200 to 300°C), otherwise ±2.7°F (±1.5°C)
Display Resolution0.1°
Units°C/°F
Response TimeApprox. 3-4 seconds from ambient to 32°F ±0.9°F
Auto OffAfter 35 minutes
Display Size0.45 H x 0.94 W inches (11 H x 24 W mm), automatically rotates 180°
Backlight10 seconds
Digit Size0.29 H x 0.16 W inches (7.5 H x 4.0 W mm)
Probe4.8 L x 0.1 dia. inches; reduces to 0.67 L x 0.06 (1/16") dia. inches (125 L x 2.5 dia. mm; reduces to 17 L x 1.5 dia. mm), Thermistor. Approx. 0.25 inch (6.4 mm) minimum immersion.
Water ResistanceIP67
Battery3 volt, type CR1632 or equivalent x 1 piece (included)
Battery Life3,000 hours continuous use
Product Size8.3 H x 0.9 W x 0.6 D inches (211.5 H x 23 W x 16 D mm)
Operating Range32 to 122°F (0 to 50°C)

Cooking Temperature Guide

The following tables provide recommended internal temperatures for various foods, ensuring optimal taste and safety. Note that meats should ideally be removed from heat a few degrees below the target temperature to allow for carryover cooking during resting.

Chef-Recommended Temperatures

Beef, Veal & Lamb (Roasts, Steaks & Chops)

DonenessTemperature (°F)Temperature (°C)
Rare120-13049-54
Med. Rare130-13554-57
Medium135-14557-63
Med. Well145-15563-68
Well Done155°F-up68°C-up

Pork (Roasts, Steaks & Chops)

DonenessTemperature (°F)Temperature (°C)
USDA-Done14563
Well Done150°F-up66°C-up

BBQ (Brisket, Ribs, & Pork Butt)

DonenessTemperature (°F)Temperature (°C)
Done190-20588-96

Note: Chef-recommended temperatures are consistent with many expert sources for taste and safety. USDA-recommended temperatures are 5 to 10°F (2 to 5°C) higher.

Minimum Done Temperatures for Food Safety

Food ItemTemperature (°F)Temperature (°C)
Ground Meat: Beef, Veal, & Sausage*16071
Ham (raw)16071
Ham (pre-cooked)14060
Egg dishes16071
Casseroles & Leftovers16574
Chicken, Turkey & Duck (whole or pieces)*16574
Poultry Dark Meat**17579
Stuffing (in the bird)16574
Tuna, Swordfish & Marlin**12552
Other Fish**14060

Water Temperatures (at sea level)

Water UseTemperature (°F)Temperature (°C)
Poach160-18071-82
Low Simmer18082
Simmer18585
Slow Boil20596
Rolling Boil212100

Other Food Temperatures

Food ItemTemperature (°F)Temperature (°C)
Bread: Rich Dough190-20088-93
Bread: Lean Dough200-21093-99
Water temp to add active dry yeast105-11541-46
Butter: Chilled352
Butter: Softened60-6716-19
Butter: Melted & Cooled85-9029-32

Candy or Sugar Syrup Temperatures (at sea level)

StageTemperature (°F)Temperature (°C)
Thread230-234110-112
Soft Ball234-240112-116
Firm Ball244-248118-120
Hard Ball250-266121-130
Soft Crack270-290132-143
Hard Crack300-310149-154
Caramel320-350160-177
Syrup
Fondant, Fudge & Pralines
Caramels
Divinity & Nougat
Taffy
Brittles, Lollipops & Hardtack
Flan & Caramel Cages
Models: Executive Series, EXEC Needle Thermometer, EXEC Needle

File Info : application/pdf, 2 Pages, 407.33KB

PDF preview unavailable. Download the PDF instead.

exec operating instructions

References

Adobe PDF Library 15.0 Adobe InDesign 16.0 (Macintosh)

Related Documents

Preview OutWard™ Digital Thermometer Operating Instructions and Temperature Guide | ThermoWorks
Comprehensive operating instructions and temperature reference guide for the ThermoWorks OutWard™ digital thermometer, featuring accuracy, IP67 rating, and detailed cooking temperature charts.
Preview ThermoWorks RT801 Digital Fridge/Freezer Alarm Thermometer User Manual
Comprehensive guide to the ThermoWorks RT801 Digital Fridge/Freezer Alarm Thermometer, covering setup, operation, features like display backlight and min/max memory, technical specifications, and support.
Preview BEEP Mini Digital Thermometer - Operating Instructions and Probe Care
Comprehensive operating instructions for the ThermoWorks BEEP Mini dual-zone digital thermometer. Learn about device features, button functions, calibration, battery installation, and essential care for Pro-Series ambient probes. Includes safety warnings and contact information.
Preview RFX MEAT Wireless Meat Thermometer Operating Instructions | ThermoWorks
Official operating instructions for the ThermoWorks RFX MEAT wireless meat thermometer, covering setup, charging, usage tips, and compliance information.
Preview ThermoPop 2 Operating Instructions and Food Temperature Guide | ThermoWorks
Comprehensive operating instructions for the ThermoPop 2 digital thermometer by ThermoWorks, featuring quick response, auto-rotating display, and detailed food safety and cooking temperature charts for meats, water, and candy.
Preview ThermoWorks IR-IND & IRK-2 Infrared Thermometer: Operating Instructions & Specifications
Comprehensive operating instructions, features, troubleshooting, and specifications for ThermoWorks IR-IND and IRK-2 industrial and infrared thermometers. Learn how to use, maintain, and troubleshoot your device.
Preview RFX MEAT Wireless Temperature Probe User Manual & Specifications
User manual and technical specifications for the RFX MEAT wireless temperature probe by ThermoWorks. Learn about setup, operation, battery, transmission, cautions, and FCC compliance.
Preview ThermoWorks Smoke X2/X4 TRIM Function Guide: How to Calibrate Your Thermometer
Learn how to use the TRIM function to calibrate your ThermoWorks Smoke X2/X4 thermometer for enhanced accuracy using a simple ice bath method. Step-by-step instructions provided.