INSTALL GUIDE - 6 BUTTON KEYPAD DIMMER

WARNING: SHOCK HAZARD Turn OFF the power to the branch circuit for the switch and lighting fixture at the service panel. All wiring con-nections must be made with the POWER OFF to avoid personal injury and/or damage to the dimmer. This device is intended for installation in accordance with the National Electric Code and local regulations in the United States and the Canadian Electrical Code and local regulations in Canada. If you are unsure or uncomfortable about performing the installation, consult a qualified electrician

6 Button Keypad Dimmer Wiring / Installation Instructions Wire strip length

1. Shut off power to the circuit at circuit breaker or fuse box IMPORTANT: Verify power is OFF to switch box before continuing.

For attachment using the enclosure's holes, strip insulation 5/8in (16mm). UL specifies the tightening torque for the screws is 14Kgf-cm (12lbf-in).
Please refer to diagram and follow steps below.

2. Remove wallplate 3. Remove the switch mounting screws 4. Carefully remove the switch from the switch box. DO
NOT disconnect the wires. 5. There are up to five screw terminals on the switch,
these are marked:
a. GROUND b. LINE -- Black (connected to power) c. LOAD -- Black or Red (connected to lighting/load) d. TRAVELER -- Black or Red (only in 3-way installations)

1. Connect the green or bare copper ground wire to the GROUND terminal
2. Connect the black wire from the light to the LOAD terminal
3. Connect the black wire from the electrical service panel (hot) to the LINE terminal
4. Connect the white wire to the NEUTRAL terminal (use a jumper wire if needed) Note: The traveler terminal is only used for 3-way or 4-way wiring and should not be connected if the dimmer is being installed in a 2-way system (one dimmer & one load)

e. NEUTRAL -- White f. Match these screw terminals to the wires connected
to the existing switch. 6. Disconnect the wires from the existing switch. Label
wires according to the previous terminal connection.
Multi-switch wiring

5. Insert dimmer into the switch box being careful not to pinch or crush wires
6. Switch must be independently mounted (vertical position only)
7. Secure the switch to the box using the supplied screws 8. Mount the wallplate 9. Reapply power to the circuit at fuse box or circuit

For 3-way installations, please refer to the companion switch manual.

breaker and test the system Basic operation

Wire gauge requirements Use 12AWG or 14AWG wires suitable for at least 75ºC for supplying line (hot), load, neutral, ground, and traveler connections.

The connected light can be turned ON/OFF in two ways
1. Manually from the front panel of the dimmer
2. Remotely via SAVI Server: Manual control

The Keypad allows the user to: Turn ON/OFF or Dim UP/DN the connected fixture

1. Press the top button to turn the light ON or press the bottom to turn it OFF
2. Press/ hold the UP arrow to dim the light UP, or press/ hold the Down Arrow dim DOWN

IMPORTANT: This 6 Button Keypad Dimmer is rated for and intended to only be used with copper wire.

Page 1

www. hellosavi.com

© 2023 SAVI Controls Rev.09/12/23

INSTALL GUIDE - 6 BUTTON KEYPAD DIMMER

QK6APD-01

QK6APD-01

Note: For 3-way configurations, ensure the smart dimmer is installed in the junction box where Line (Hot) enters the electrical circuit. Insert wires into holes, do not wrap wires around screws. Do not remove screws.
The Qoralux 6 Button keypad Dimmer is designed to operate in either 120VAC or 277VAC circuits. For 277VAC 3-way circuits, use standard "off-the-shelf" 277VAC compatible 3-way switch.

LEGAL
Resistive: 15A@120/277V Incandescent: 960W@120V/1385W@277V Operating ambient temperature 0-40°C Method of mounting included: Independently mounted (Vertical position only) Operating control, Type 1.C action Pollution Degree 2 Rated Impulse Voltage 4000 V Software Class A NEMA type 1 enclosure FOR INDOOR USE ONLY

FCC
Supplier's Declaration of Conformity 47 CFR 2.1077 Compliance Information Model: QK6APD-01 Responsible Party ­ US Contact Information 2520 Marsh Lane, Carrollton, TX 75006-2401 (214) 785-6510
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment. Such modifications or changes could void the user's authority to operate the equipment. Please visit savicontrols.com to find the full FCC/IC statements.
IC
This device complies with Part 15 of the FCC Rules and with RSS of Industry Canada. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
1. L'appareil ne doit pas produire de brouillage, et 2. L'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le
fonctionnement.
This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

Page 2

www. hellosavi.com

© 2023 SAVI Controls Rev.09/12/23

FCC This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with a minimum distance of
20cm between the radiator and any part of your body.
IC This equipment complies with ISED RSS-102 radiation exposure limits set forth
for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of
20cm between the radiator and any part of your body. Pour se conformer aux exigences de conformité CNR 102 RF exposition, une
distance de séparation d'au moins 20 cm doit être maintenue entre l'antenne de cet appareil ettoutes les personnes.
FCC ID:2BAZT10024001 IC:30526-10024001

