HANYOUNG NUX logo

Built-in power(A) / Built-in amplifier(N,P) photo sensor
PEA series
INSTRUCTION MANUAL

Thank you for purchasing Hanyoung Nux products.
Please read the instruction manual carefully before using this product, and use the product correctly.
Also, please keep this instruction manual where you can see it any time.

Safety information

Please read the safety information carefully before use, and use the product correctly.
The alerts declared in the manual are classified into Danger, Warning and Caution according to their importance

Warning icon DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury
Warning icon WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury
Warning icon CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor injury or property damage

Warning icon DANGER

• The input/output terminals are subject to electric shock risk.
Never let the input/output terminals come in contact with your body or conductive substances.

Warning icon WARNING

  • This product is not for outdoor use (it may shorten the product lifetime and cause electric shock)
  • Do not use this product in places with flammable or explosive gases (it does not have an explosion-proof structure, so there are fire or explosion risks)
  • Do not use the product in places where vibrations or shocks exceed the reference values (it has a double insulation structure, but the components may be damaged)

Warning icon CAUTION

  • Applicable Pollution degree 3 of intended environment.
  • Never use it on AC power.
  • Be careful of wiring. It may cause explosion, fire, or machine breakdown.
  • Do not use the product in a state where the product body or cable is crashed.
  • Do not disassemble, repair or modify the product.
  • When the lens of the photo sensor is contaminated by foreign substances, use a dry piece of cloth and wipe off the substance lightly. Never use thinner or organic solvents.
  • Separate high voltage cable and power line from the sensor wire.
    Be cautious since using the same pipe during wiring could cause malfunction.
  • If the cable needs to be extended, use over 0.3 ㎟ and be cautious because of a possible sudden voltage drop.
  • When using the sensor under lights with high frequency, such as fluorescent lamps or mercury lamps, block it with a light shading plate and avoid the lens from facing the light directly.
  • If multiple through-beam type photoelectric sensors are installed close together, malfunction may happen due to the mutual interference.
  • Using inductive load (relay, coil) for the output can cause an instantaneous increase in load by more than two times and damage the TR of the output. Therefore, please set half of the maximum load.
  • There is an over-current protecting circuit within the output side that breaks the output when the current is higher than the rated load current. Therefore, please set within 70% of the maximum load.
  • Do not use the product in places with heavy dust or debris that can contaminate the lenses and consequently cause malfunctions.
  • The contents of this manual may be changed without prior notification
  • Any use of the product other than those specified by the manufacturer may result in personal injury or property damage.
  • When using the Switching Power Supply as power source, ground the Frame Ground (F.G.) terminal and be sure to connect the noise-cancelling condenser between OV and F.G. terminals
  • The power supply should be insulated and limited voltage/current or Class 2, SELV power.

Specification

Sensing mode Through – beam Retroreflective(MS.R.) Diffuse- reflective
Model Relay output (AC/DC power) PEA-T30A PEA-M5A PEA-R2A
NPN Open collector output
(DC power)
PEA-T30N PEA-M5N PEA-R2N
PNP Open collector output
(DC power)
PEA-T3OP PEA-M5P PEA-R2P
Sensing distance 30m 0.1 – 5 m 2m
Hysteresis distance 20%aless cf detection distance
Detecting object 012 mm more (Opaque) 060mm more (Opaque) White paper (100 x 100 mm)
Light source (wavelength) Infrared light emitting diode (855 nm) Red light emitting diode (660 nm) Infrared light emitting diode (855 nm)
Power voltage Relay output (AC/DC power) 24 – 240V a.c. ±10 %or 24.240 V d.c. ±10% (Ripple max. 10%)
Open collector output (DC power) 12 – 24V d.c. Class 2 ± 10% (Ripple max. 10%)
Power consumption Relay output (AC/DC power) •Transmitter Max. 1VA,
•Receiver Max. 2VA
Max. 3VA
Open collector output (DC power) •Transmitter Max. 15 mA •Receiver Max. 20 mA Max. 35 mA
Control output Relay output (ACA:)C power) • Relay contact output (Contact configuration lalb) • Electrical life: Min. 100,000 cycles
• Contact Capacity: 30 V d.c. 5A/ • Mechanical life : Min. 50million cycles 250 V a.c. 5 A with resistive bad (Opening/closing frequency 180 times/min))
Open collector output
(DC power)
•NPN or PNP open collector output
•Load current – Max. 100 mA (26.4 V d.c. standard) • Residual voltage – Max. 1.5 V
Operation mode Light ON / Dark ON button switch type
Indicator light Control output indicator light : Orange LED, Stability indicator light: Green LED
(However, the Green LED of the through-type emitter is a power indicator)
Auto-teaching See How to set sensitivity and operation mode → Section a).
AGC After 20 seconds of unstable light entering on button locked gate to stable light entering state
Sensitivity adjustment B1 increase the sensitivity and B2 decreases the sensitivity
Protection circuit Common I Mutual interference prevention function
Open collector output (DC power) Power reverse connection protection, Output short-circuit over-current protection,
Output reverse connection protection, Output short-circuit alarm
Response time Relay output (AODC power) Max. 20 us
Open collector output (DC power) Max. 1 ms
Insulation Resistance More than 20 MO (500V d.c. mega)
Dielectric strength 1,000 V ac. (50/60 Hz for 1 minute)
Vibration resistance 10-55Hz, sweep’. 1.5mm, X•Y•2 2 in each direction for 2 hours
Shock resistance 500 m/s2, X•I each direction 3 times
Ambient illumination Sunlight: max. 11,000 lx / Incandescent: max 3,000 k
Ambient temperature range Operating temperature : -20 —455 °C , During storage: -40 — .10°C (Without condensation or icing)
Ambient humidity 35 — 85 %RH (Without condensation or icing)
Protection IP67 (IEC standard)
Weight (Packing) Relay output (ACIOC power) 265g (440g) 150g (280g) 145g (260g)
Open collector output (DC power) 255g (4300 140g (270g) 140g (255g)
Texture Case PC
Display PC
Lens PMMA
Accessory Common Instructions manual, bracket, bolt (M3 X 12 mm)
Accessory I Mirror (HY-M5)
Connection method Cable type
Wiring specification Relay output (ACIDC power) 0 6 mm, Through-beam type transmitter: 2-core, Through-beam type receiver, Mirror-reflection type,
Diffuse-reflective type: 5-core, 2 m
Open collector output
(DC power)
0 6 mm, Through-beam type transmitter: 2-core, Through-beam type receiver, Mirror-reflection type,
Diffuse-reflective type: 5-core, 2 m
Specifications of the small-sized cable AWG20 (0.18 mm, 21 wire), Insulation outer diameter: 1.5 mm

▪ Mutual interference prevention function
▪ Resistant to noise by adopting digital signal processing
▪ M.S.R. that receives only the light reflected from the mirror
▪ IP67 (IEC standard) protection structure with excellent water resistance
▪ Realization of long-distance detection by adopting high-performance lens

Suffix code

Model Code Content
PEA- HANYOUNG NUX PEA Series Built in Amplifier - Symbol 1 HANYOUNG NUX PEA Series Built in Amplifier - Symbol 1 HANYOUNG NUX PEA Series Built in Amplifier - Symbol 1 PEA series
Sensing mode M Through-beam
R Diffuse-reflective
30 30  Through-beam)
Sensing distance 5 5 m (Retroreflective)
2 2 m (Diffuse-reflective)
A Relay contact output   / AC/DC power
Control output N NPN Open collector output DC power
P PNP Open collector output DC power

How to set sensitivity and operation mode

NO Function Information
1 Button lock 84unlock Press the B1HANYOUNG NUX PEA Series Built in Amplifier - Symbol 2button for more than 3 seconds to change (lock or unlock).
3 Auto- teaching Through-beam If the B2 HANYOUNG NUX PEA Series Built in Amplifier - Symbol 3 button is pressed for more than 3 seconds in the presence of a detection object, the sensitivity is automatically set.
Retroreflective (M.S.R.)
Diffuse- reflective 1)  In the presence of a detection object (stable light incident)
2)  Release the B2 HANYOUNG NUX PEA Series Built in Amplifier - Symbol 3 button after pressing it for more than 3 seconds.
3)  Check the Green + Orange LED cross blinking (try again if either side is not blinking)
4)  Press the B2 HANYOUNG NUX PEA Series Built in Amplifier - Symbol 3 button once after removing the detected object (0.5 seconds)
4 Increase sensitivity Press the B1 HANYOUNG NUX PEA Series Built in Amplifier - Symbol 2 button for less than 3 seconds to increase the fine sensitivity (1 STEP)
5 Decrease sensitivity If the B2HANYOUNG NUX PEA Series Built in Amplifier - Symbol 2 button is pressed for less than 3 seconds, the fine sensitivity decreases (1STEP)
6 Operation mode change Press the B1HANYOUNG NUX PEA Series Built in Amplifier - Symbol 2+B2HANYOUNG NUX PEA Series Built in Amplifier - Symbol 3 buttons simultaneously for 5 seconds or longer to change the operation mode (Light ON4->Dark ON)
7 Factory reset After pressing the B1 HANYOUNG NUX PEA Series Built in Amplifier - Symbol 2 +B2 HANYOUNG NUX PEA Series Built in Amplifier - Symbol 3 buttons together for more than 5 seconds, release only B1 HANYOUNG NUX PEA Series Built in Amplifier - Symbol 2After 5 seconds, release the B2 HANYOUNG NUX PEA Series Built in Amplifier - Symbol 3 button to reset. (Dark ON, sensitivity maximum, button unlock changes, and diffuse reflection type becomes Light ON.)_
8 AGC Unstable light If it lasts more than 20 seconds, it is adjusted to stable light incident state.

Operation in button unlocked state

HANYOUNG NUX PEA Series Built in Amplifier - Fig 1

Indicator light state

1 Button lock Within 3 seconds (Green blinking) → After 3 seconds (Orange ON), release the B1 button, Green + Orange blinking (2 seconds)
※ Setting value cannot be changed when button locking or unlocking is operated
2 Button unlock Within 3 seconds (Green + Orange blinks) → After 3 seconds (Orange ON), release the B1 button, Green + Orange blinks (2 seconds)
3 Auto-teaching Through-beam Within 3 seconds (Green blinking) → After 3 seconds (Orange ON) → When the B2 button is released, Green + Orange blinks alternately (5 seconds)→  Green blinks (2 seconds)
Retroreflective (M.S.R.)
Diffuse- reflective If you press the B2 button once when there is Green + Orange blinking (0.5 seconds), Green blinks 6 times.
※ If auto-teaching is attempted while the light from the emitter does not enter the receiver, the Orange blinks (Error displayed fort seconds)
4 Increase sensitivity Within 3 seconds (Green blinking)
5 Decrease sensitivity Within 3 seconds (Green blinking)
6 Operation mode change Within 5 sec ( Green + Orange OFF) → After 5 sec (Green + Orange ON) → Release B1 + B2 button to blinking Green (2 sec)
7 Factory reset Within 5 sec (Green+Orange OFF) → After 5 sec (Green+Orange ON) → Release B1 button to blinking Green + Orange ON (5 sec) → After 5 seconds (Green ON) → B2 button is released, Green blinks (2 seconds)
Etc Save previous execution value 10 – ® Saved after a certain period of time after performing the operation (no arbitrary operation), blinking Green (1 time)After saving the operation value, even if the power is turned off and on, the previous operation value is saved (automatically saved even in case of power failure)

Connection diagram

■ Relay contact output

HANYOUNG NUX PEA Series Built in Amplifier - Fig 2

■ NPN TYPE

HANYOUNG NUX PEA Series Built in Amplifier - Fig 3

■ PNP TYPE

HANYOUNG NUX PEA Series Built in Amplifier - Fig 4

Dimension

HANYOUNG NUX PEA Series Built in Amplifier - Fig 5

How to install

HANYOUNG NUX PEA Series Built in Amplifier - Fig 6

Accessories

Bracket

HANYOUNG NUX PEA Series Built in Amplifier - Fig 7

Reflector (HY-M5)

HANYOUNG NUX PEA Series Built in Amplifier - Fig 8

Output operation characteristic

HANYOUNG NUX PEA Series Built in Amplifier - Fig 9

HANYOUNG NUX logo

Documents / Resources

HANYOUNG NUX PEA Series Built in Amplifier [pdf] Instruction Manual
PEA-R2A, PEA Series Built in Amplifier, PEA Series, Built in Amplifier

References

Leave a comment

Your email address will not be published. Required fields are marked *