HANK ZSE18800 Motion Sensor
Specifications
- Product Name: Motion Sensor
- Model NO: ZSE18 800LR
Product General Description
The Motion Sensor ZSE18 800LR is a device designed to detect motion and send notifications to connected devices. It is commonly used for home security systems and automation purposes.
User Manual
Product Name : | Motion Sensor |
Model NO : | ZSE18 800LR |
Product General Description
Product Picture
Product Introductions
This product is an intelligent sensor developed based on Z-Wave, which can be used for illegal intrusion detection in unmanned areas. It is suitable for most regions in Europe and America. The main functional features are as follows:
- Remote monitoring of human activity and reporting of alarm information through the Z-Wave system;
- As a standard Z-wave device, this product supports the Z-Wave Plus protocol and can work in our company’s Z-Wave gateway or third-party gateway that supports Z-Wave Plus;
- Support Z-wave long range, with wider wireless coverage, scalable network node characteristics, and lower power consumption;
- Support LED indication of working status: inclusion, exclusion etc;
- 1 CR123A battery (nominal 3V) or USB powered;
- Ultra low standby power consumption, which can be used for a long time;
- Equipped with tamper detection function;
- Strong magnetic suction bracket that can rotate to achieve multi-angle detection;
- Support OTA upgrade;
- Z-wave 800 series chip (ZG23A020)
- Compliance with CE, FCC, and ROHS;
Product Feature
Product Electrical Specification
Function | Description |
Inclusion | When the product is outside of network, if the controller is adding the device, and the product enters into learning mode (sending Node Info), then the product will be added to the controller’s network. |
Exclusion | When the product is inside of network,and a controller is at adding devices Mode, and the product is at learning mode (sending Node info), the product
will be removed in the controller network. |
Wake Up |
|
Setting for the Sleep and Wake cycle |
|
Report PIR motion |
|
Report battery power |
|
Report low
battery |
When the battery level drops below the set minimum value, an alarm will sound (configurable by parameter 32) |
Report Tamper | When the tamper is triggered, a report will be sent to the controller, the Notification Report Event= Tampering product covering removed (03); When the tamper is untriggered, after 3seconds, a cleaning event report will be sent. |
OTA | Firmware can be upgraded through the z-wave network. |
Factory data
reset |
Restore all configuration to default values and exclude the device to the network. |
Definition of button and indicator light
Keypad Function Description
2.2 Definition of button and indicator light
2.2.1 Keypad Function Description |
|||||
Trigger mode | Network state | LED | Function description | ||
Start | In the network | Power on: light on for 3 seconds, then off | — | ||
Outside the network | Power on: flashing slowly 3 times | Enter “SmartStart” function; The
indicator will be off after the success of inclusion |
|||
Short press 1 time | In the network | Flash 1 time | Wake up device | ||
Outside the network | LED keep quick flashing and enter learning mode;
|
Enter “learn” function. Sending node info. The LED indicator will be solid on for 2S and then off after the inclusion. | |||
Triple click |
Outside the network | LED keep quick flashing and enter learning mode;
|
Enter “learn” function. Sending node info. The LED indicator will be solid on for 2S and then off after the inclusion. | ||
In the network | LED keep quick flashing and enter learning mode;
|
Enter “learn” function. Sending node info. The LED indicator will be solid on for 2S and then off after the exclusion. | |||
Long press | In the network | 1~3s,on | — | ||
3~10S, flashing quickly | long press the button till the LED flashing quickly , it will send “wake up notification” And then LED indicator will be off after receive” wake up no
more information” |
||||
>=20S , solid on | Restore to factory Settings, sending “Device Reset locally” to notify the controller. | ||||
Tamper/motion triggered | In the network | Flash 1 time | — | ||
sleep | In the network | Be off | — | ||
Button definition
Definition of actions | Action time interval (seconds) |
Short press | < 1s |
Long press | >=1s |
Indicator light definition
Flashing way | definition |
Slow flash | Blink every 2S. |
Quick flash | Blink every 0.5 seconds. |
- Reference To Standard FCCE ,ROHS
Environment Condition
NO | Items | Parameter | Unit | Remark |
1 | Operating Temperature | -10~+40 | ℃ | |
2 | Storage Temperature | -20~+60 | ℃ | |
3 | Relative Humidity | 8~80 | %RH |
Electrical Characteristics
Basic Characteristic
NO | Items | Parameter | Remar
k |
||
Min. | Typ. | Max. | |||
1 | Input voltage range | 2.0V | — | 3V | |
2 | Standby Current | — | 6mA | 10mA | |
3 | Standby Current | — | 40uA | 80uA | |
4 | Default Power | — | CR123A*1 /
USB |
— | |
5 | Default Battery Capacity | — | 1300mAh | — |
PIR Characteristic
NO | Items | Parameter | Remar
k |
||
Min. | Typ. | Max. | |||
1 | Detection Distance | 6m | 8m | 10m | |
2 | Detection Angle | — | — | 120º | |
3 | Sensitivity Level | 1 | 8 | 8 |
Wireless Characteristics
NO | Items Types | Parameter | Remark | ||
Min. | Typ. | Max. | |||
1 | Frequency range | 1)908.4MHz
2)912.0MHz |
— | 916.0MHz
920.0MHz |
US |
2 | Indoor communication
distance |
30M | — | — | |
3 | Outdoor communication distance | 100M | — | — | |
Z-Wave Software Function Description
SDK:7.18.4
Wave Plus device type
Device Type | Basic device feature | Specific device feature | Role Type |
Sensor – Notification | GENERIC_TYPE_SENSOR
_NOTIFICATION |
SPECIFIC_TYPE_NOTIF
ICATION_SENSOR |
Reporting
Sleeping Slave (RSS) |
Command list
Command | Version | Security type |
COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | 2 | None |
COMMAND_CLASS_TRANSPORT_SERVICE_V2 | 2 | None |
COMMAND_CLASS_SECURITY_2_V1 | 1 | None |
COMMAND_CLASS_SUPERVISION_V1 | 1 | None |
COMMAND_CLASS_APPLICATION_STATUS_V1 | 1 | None |
COMMAND_CLASS_BASIC | 3 | S0/S2 Authenticated/Unauthenticated |
COMMAND_CLASS_NOTIFICATION_V8 | 8 | S0/S2 Authenticated/Unauthenticated |
COMMAND_CLASS_BATTERY_V1 | 1 | S0/S2 Authenticated/Unauthenticated |
COMMAND_CLASS_WAKE_UP_V2 | 2 | S0/S2 Authenticated/Unauthenticated |
COMMAND_CLASS_CONFIGURATION_V4 | 4 | S0/S2 Authenticated/Unauthenticated |
COMMAND_CLASS_ASSOCIATION_V2 | 2 | S0/S2 Authenticated/Unauthenticated |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | 3 | S0/S2 Authenticated/Unauthenticated |
COMMAND_CLASS_VERSION_V2 | 3 | S0/S2 Authenticated/Unauthenticated |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_ V2 | 2 | S0/S2 Authenticated/Unauthenticated |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V 1 | 1 | S0/S2 Authenticated/Unauthenticated |
COMMAND_CLASS_POWERLEVEL_V1 | 1 | S0/S2 Authenticated/Unauthenticated |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | 5 | S0/S2 Authenticated/Unauthenticated |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIAT ION_V3 | 3 | S0/S2 Authenticated/Unauthenticated |
COMMAND_CLASS_INDICATOR_V3 | 3 | S0/S2 Authenticated/Unauthenticated |
Command description
Z-Wave Plus Info Report Command
Parameter | Value |
Z-Wave Plus Version | 2 |
Role Type | 6 (ROLE_TYPE_SLAVE_SLEEPING_REPORTING) |
Node Type | 0 (ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE) |
Installer Icon Type | 0x0C07 (ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_HOME_SECURI TY) |
User Icon Type | 0x0C07 (ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_HOME_SECURI TY) |
Association command
Support two groups of associated nodes, each with a maximum of five node Numbers.
Group ID | Support Node | Support commands |
Group 1(Lifeline) | 5 |
|
Group 2(On/Off
control) |
5 |
|
Manufacturer-Specific Report command
Par | Value(Hex) |
Manufacturer ID 1 | 0x02 |
Manufacturer ID 2 | 0x7A |
Product Type ID 1 | 0x03 |
Product Type ID 2 | 0x01(US) |
Product ID 1 | 0x00 |
Product ID 2 | 0x12 |
Version Report command
Parameter | Value(HEX) |
Z-Wave Protocol Library Type | 0x03 |
Z-Wave Protocol Version | 0x07 |
Z-Wave Protocol Sub Version | 0x13 |
Firmware 0 Version | Firmware 0 version |
Firmware 0 Sub Version | Firmware 0 Sub Version |
Hardware Version | 0x01 |
Number of Firmware Targets | 0x00 |
Notification command
Notification type | Notification Event | Description |
Home Security (0x07) | (0x00) State idle | Notification value for the state variable going to idle. |
(0x08) Motion detection | When motion triggered. | |
(0x03) Tampering, product moved | When vibrating. | |
Power Management (0x08) | (0x02)AC mains disconnected | When USB is disconnected and insert the battery again. |
(0x03)
AC mains re-connected |
When insert the USB cable.
TIP: When powered by USB, the device will work as a repeater. |
- When PIR is triggered, send Motion Detection Unknown Location (08);
- When PIR detection is cleared, send Previous Events cleared (00),Parameter 1 is Motion Detection Unknown Location(08);
- When Tamper/motion is detected, send Tampering Product covering removed (03);
- The report that Event is cleared will be sent after 2.5s, Previous Events cleared (00), and Parameter 1 is Tampering Product covering removed (03);
Wake Up command
- When the device is included,short press Z-Wave button one time,after release, it will send Wake Up Notification
- Use command “wake up interval set” to configure the interval time of wake up. If the configured time is less than 3600 seconds, the device will not automatically wake up. The minimum unit configured by the user is 60 seconds, such as:
- When the configured time is 3600-3659, the actual wake-up time is 3600 seconds.
- When the configured time is 3660-3719, the actual wake-up time is 3660 seconds.
- When the configured time is between 3720 and 3779, the actual wake-up time is 3720 seconds.And so on.
- Wake Up Interval Capabilities Report CC
- Minimum Wake Up Interval Seconds = 3600s
- Maximum Wake Up Interval Seconds = 3600×24,equal to 24h
- Default Wake Up Interval Seconds = 14400 seconds (4 hours)
- Wake Up Interval Step Seconds = 3600 S
Battery command
- Send ”battery get” command to the device, Report the current battery power when it wakes up. It report 100%power level when the power is up to 3V. 0% when the power is 2.0V.
- When the device is low voltage,(Par 32 can Configure the threshold,The default value is less than 20%), Report to the group 1 associated node “Battery report 0xff”.
Configuration command
Par | Bytes | Default
value |
Desriptions |
12 | 1 | 8 | PIR Sensitivity configuration
|
14 | 1 | 0 | When the PIR is triggered,whether to send the Basic Set command.
|
15 |
1 |
0 | When the PIR is triggered, the way of sending Basic Set command:
0 - When PIR is triggered, send Basic Set 0xFF; When PIR is cleared, send Basic Set 0x00.
|
16 | 1 | 0 | When the PIR is untriggered, whether to send the Basic Set command.
|
17 | 1 | 0 | Enable/Disable Tamper detection:
|
18 | 2 | 30 |
|
19 |
1 | 1 | Whether to send the Binary Sensor Report. 0- Not send Binary Sensor Report, only send notification1- Only send Binary Sensor Report, not send notificationTip: The Z-Wave 800 series has abandoned the
Sensor Binary and is not recommended for further use. |
20 |
1 |
1 |
Enable or disable LED indicator for motion alerts.
TIP: Click the button 6 times quickly to change the LED indicator mode manually. |
||
32 | 1 | 20 | Threshold value to enable battery power report when the battery is changed value exceeds the value.
effective value: 10~50%; |
||
254 | 1 | 0 | The Configuration function is locked, and after locking, except for this parameter, the values of other parameters cannot be changed:
|
||
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
FCC StatementThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
The equipment complies with FCC Radiation exposure limit set forth for uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. |
Documents / Resources
![]() |
HANK ZSE18800 Motion Sensor [pdf] User Manual ZSE18800 Motion Sensor, ZSE18800, Motion Sensor, Sensor |