Button Instruction

Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (1)

Display & Operation

Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (2)

  1. Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (3)Green light indicates the device is powered on, Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (3) Red light indicates the device is powered off.
  2. Set Temp indicates the setpoint temperature which shows at the left side of the main interface, press Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (4) or Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (5) to adjust the setting temperature, then press Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (6) to confirm after the setting is completed. The temperature setpoint range is from 16-30°C(60-86°F), the adjustment range is limited in Energy Saving mode, for more information, please refer to the following Energy Saving mode description.
  3. Child Lock: Hold Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (3) and Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (7), synchronously for 3S in home page to enable the lock and unlock function.
  4. Mode Setting
    Press Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (8) button to execute mode switch.Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (9)
  5. Fan Speed Setting
    Press ◄ ► button to adjust fan speed.

Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (11)

Zone Management Control

Press Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (7) to enter zone function.

Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (12)

  1. In this interface, press Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (4)or Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (5)to switch the icon, press Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (8) to change the on/off state of the available damper, after the setting is completed, press Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (6) to execute immediately.
  2. In this screen, dampers can be opened and closed individually.
  3. ALLON &ALL OFF these icons indicate dampers can be turned on or turned off simultaneously.
  4. When the air conditioner is off, all dampers will be open automatically.

Menu Function

Press Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (13) to enter menu screen.
Use ◄ ► to shift and O to enter.

Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (14)

Calendar Setting

Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (15)

In this screen, press Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (4) or Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (5) to shift the items, press ◄ or ► to adjust the parameter.
After the date is set, the week will be automatically displayed.

Weekly Schedule

Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (18)

  1. Max. 20 timers can be set which is indicated by numbers ranging from 01 to 20.
    When the cursor is put on the timer program No., press Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (8) to confirm, then use theHaier-HW-ZA101DBT-Smartzone-Controller-FIG- (4)or Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (5) check all the timer programs. Press ◄ or ► to exit check when the cursor is put on the No ..
  2. For each timer program, user can select the related zones and days. For each timer program, the zones and days involved can be set. Press Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (19) : or ◄ ► to move the cursor and press O to confirm or cancel the selection.
  3. For the time adjustment, when the cursor fixed on the time, press Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (8) to confirm and use Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (4) to Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (5) adjust the value.
    Long press Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (4) or Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (5) to achieve quick adjustment.
  4. The set timer can be set by Enabled/Disabled. When the timer is set to Disabled, this timer function will not be executed.

AC Timer

Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (20)

  1. Max. 1 O timers can be set which is indicated by numbers ranging from 01 to 10.
    When the cursor is put on the timer program No., press Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (8) to confirm, then use theHaier-HW-ZA101DBT-Smartzone-Controller-FIG- (4)or Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (5) check all the timer programs. Press ◄ or ► to exit check when the cursor is put on the No ..
  2. For each timer program, user can select the related days. For each timer program,when the timer program setiing is valid, the days involved can be set. Press Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (19): or ◄ ► to move the cursor and press O to confirm or cancel the selection.
  3. For the time adjustment, when the cursor fixed on the time, press Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (8) to confirm and use Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (4)to Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (5) adjust the value.
    Long press Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (4)or Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (5) to achieve quick adjustment.
  4. The set timer can be set by Enabled/Disabled. When the timer is set to Disabled, this timer function will not be executed.

Zone setting for installers

Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (21)

  1. This function is only available for installers’ operation. The password is 841226.Use ◄ ► to shift digits , Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (19) to adjust value and O to confirm.
  2. The second column indicates the normal zone or the constant zone. Normal zone means
    it can be normally turned on or turned off.Constant zone means it will be automatically turned on and will be constantly on when other zones are off. When the air conditioner is OFF, all the normally-open damper will be ON automatically.
  3. The third column indicates the zones can be turned on or turned off by installers. If the zone is set off which means it will not appear to the user.
  4. The first column indicates the zone name, which is allowable for rename.
    Select the zone to be renamed, press the Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (8) to enter into the keypad window. Press Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (19) ◄ ► to select and OK to confirm.The zone name length is 6 digits.

Parameter Setting

Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (22)

Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (23)

  1. Date Format Date display format: there are three formats can be set 1 M/D/Y 2 Y/M/D 3 D/M/Y
  2. Time Format Time display format: 12-hour and 24-hour system.
  3. Screen Saving Screen saving time: 1 15s 2 30s 3 1 min 4 3min 5 the screen brightness is always on. Without any operation. the screen brightness turns off according to the set time.
  4. Volume Beep or buzzer: 1 30% 2 60% 3 1 00% 4 Off
  5. Brightness Backlight brightness setting: 1 30% 2 50% 3 60% 4 BO% 5 100%
  6. Energy saving mode:
    1. CD Only after this function is set on, the setting of the minimum energy-saving tempera­ture in Cooling/Dry mode and the maximum energy-saving temperature in Heating mode is valid. The parameter setting range is 16-30°C. The minimum energy saving temperature is 23°C (74° F) as initial default setting in Cooling/Dry mode, and the maximum energy saving temperature is 26°C (78° F) as initial default setting in Heating mode.
    2. After this function is actived, the setpoint temperature setting range is limited to 23-30 C in Cooling/Dry mode, in Heating mode it is limited to 16-26°C
    3. The energy saving function is initially off. by default.
  7. ESP Grade Static pressure setting: It can be adjusted based on actual static pressure grades of indoor unit.
  8. Room Temp.Collection The room temperature data source can be selected from: CD  Controller 2 Interface 3 IDU
  9. F/C Fahrenheit/Celsius temperature format switch: after the format is set, all temperature parameters will be followed to the set format.
  10. Cool Temp. Compensation Heat Temp. Compensation Cooling/Heating temperature compensation for indoor unit, this function is mainly operated by installer to set the indoor temperature compensation for indoor unit. Some indoor unit doesn’t support this function, the icon displays grey indicating that it is not adjustable.
  11. Main/Sub Main/Sub controller setting: when it is set to slave, some functions cannot be set.
  12. Filter Reset Filter Reset: when the controller display filter icon, indicating that it can be reset and cleared.
  13. Factory Reset Factory Reset: when the factory reset is set into on, all the settings will reset to the factory defaults
  14. Temp.compensation
    1. When it is Celsius, the range of parameter adjustment is -4 – 4. When it is Fahrenheit, the range of parameter adjustment is -8 – 8.
    2. This function is valid only during collecting ambient temperature of wired controller.
  15. Zone.Hd Reverse
    Change the operating status of the air valve.

ErrorCode

Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (24)

In this interface, the current faults and historical faults can be checked. Press Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (8) to delete all historical faults.

Interface

Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (25)

There are 8 indicator lights on the interface which indicates 8 dampers.When the damper opened, the red indicator light turns on. When the air valve closed, the red indicator light turns off.

Wired Controller Wiring Instruction

Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (26)

Note

Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (27)

  1. The wire connecting damper and control interface should be field supplied. Be sure the wire sequences are the same otherwise the damper will not be controlled normally.
  2. The power consumption of 24V AC power adapter should not be less than the total power consumption of the whole zone system.The total power consumption includes the power consumption of total dampers involved( VA per damper times installed zones qty.) and the control box (approximately 5w).For example, the power consumption per damper is 5w and the zones installed are 8. In this case, to ensure the zone system works normally, the 24V AC power adapter should not be less than 45VA .
  3. The indoor unit PCB connecter to zone controller is same as the connecter to wired controllers, please check the indoor unit wiring diagram
Communication Wiring Length Dimension of Wiring
0-100 ft (0~30m) 22AWG(0.3mm2)x3-core shielded wire
100-200 ft (30-60m) 20AWG(0.5mm2)x3-core shielded wire
200-300 ft (0~90m) 1SAWG(0.75mm’ )x3-core shielded wire

Installation instruction
Haier-HW-ZA101DBT-Smartzone-Controller-FIG- (28)

  1. Use a screwdriver to take apart the controller bottom shell.
  2. Use a screwdriver to take apart the cover plate of the connection terminal for wiring connection. After the wiring connection is completed, install the bottom shell of the controller on the wall.
  3. Connect the wired product to its upper buckle along the arrow direction of the bottom shell of the controller, and then press the lower part evenly.
  4. Check the whole device is installed correctly, then power it on and operate according to the user manual.

Documents / Resources

Haier HW-ZA101DBT Smartzone Controller [pdf] User Manual
LOWPROFILEDUCTED, HIGHSTATICDUCTED, HW-ZA101DBT Smartzone Controller, Smartzone Controller, Controller

References