hager NC410A Automatic Switch Owner’s Manual

hager-logo

hager NC410A Automatic Switch

hager-NC410A-Automatic-Switch-product

Technical characteristics

Electric current

  • Rated current 10 A

Architecture

  • Type of pole 4P
  • Curve C

Capacity

  • Number of modules 4

Installation, mounting

  • Nominal tightening torque top terminal 2.80 – 2.80 Nm
  • Nominal tightening torque down terminal 2.80 – 2.80 Nm
  • Nominal tightening torque 2.80 – 2.80 Nm
  • Type of bottom connection for modular devices biconnect
  • Type of top connection for modular devices Screw terminal 360° mounting position possible Yes

Main electrical attributes
Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 10 kA

Voltage

  • Rated operational voltage Ue 230 – 400 V
  • Type voltage supply AC
  • Rated insulation voltage Ui 500 V
  • Rated impulse withstand voltage Uimp 4,000 V

Frequency

  • Frequency 50 – 60 Hz

Safety

  • Ingress Protection (IP) class IP20

Use conditions

  • Degree of pollution according to IEC 60664 /
  • IEC 60947-2 2
  • Class of energy limitation I²t 3
  • Air humidity protection For all climates
  • Operating temperature -25 – 70 °C

Power
Total power loss under IN 7.90 W

Connectivity

  • Type of connection Screw terminal
  • Top connection alignment for modular devices Aligned terminal
  • Down connection alignment for modular devices Aligned terminal

Dimensions

  • Height 83 mm
  • Width 70 mm
  • Depth 70 mm

Connection

  • Cross-section of input and output with screws, for massive conductors 1 – 35 mm²
  • Cross-section of input and output with screws, for flexible conductors 1 – 25 mm²
  • Cross-section of input with screws, for
  • flexible conductors 1 – 25 mm²
  • Cross-section of input with screws, for massive conductors 1 – 35 mm²
  • Cross-section flexible conductor 1 – 25 mm²
  • Cross-section rigid conductor 1 – 35 mm²

FAQ

  • Q: What is the maximum short-circuit breaking capacity of the NC410A MCB?
    A: The NC410A MCB has a rated short-circuit breaking capacity of 10 kA according to IEC 60898-1 standards.
  • Q: What is the voltage supply range for the NC410A MCB?
    A: The NC410A MCB is rated for an operational voltage range of 230 – 400 V AC.

Documents / Resources

PDF thumbnailNC410A Automatic Switch
Owner's Manual · 4P C-10A 4M, MCB 4P 10kA C-10A 4M, NC410A Automatic Switch, NC410A, Automatic Switch, Switch

References

Questions and answers

Helpful product questions tied to this manual. Each item links to the full Q&A page.

Browse all questions about this manual

Questions & Answers

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

  1. Cuáles son las salidas 5 y 6?

    Anonymous asks Cuáles son las salidas 5 y 6?
    Manuals+ clarified question
    Question

    What are outputs 5 and 6 on the Hager NC410A?

    Answer

    The Hager NC410A is a 4-pole (4P) Miniature Circuit Breaker (MCB). In standard 4-pole electrical components, terminals are typically numbered in pairs from left to right.

    For a 4-pole device like the NC410A:

    • Terminals 1, 3, 5, and 7 are generally the top (input) terminals.
    • Terminals 2, 4, 6, and 8 are generally the bottom (output) terminals.

    Therefore, terminal 5 is the input for the third pole, and terminal 6 is the corresponding output for that same third pole. Please note that the provided technical data sheet confirms this is a 4-module, 4-pole device, but it does not explicitly provide a wiring diagram. Always verify the terminal markings printed directly on the front or side of the physical unit before installation.